Laserfiche WebLink
�������VPASS.—A <br /> Page 13 <br /> DATE: 3/30/2022 COMPANY: American Home Planners <br /> VITRUVIUS BUILD: I StruCalc DESIGNED BY- L V <br /> CUSTOMER: Carlisle Residence REVIEWED BY: L V <br /> PROD.ADDRESS: -- PROJECT NAME: Carlisle Residence <br /> LEVEL Roof LOADING: ASD <br /> MEMBER NAME: 6x6Hf2Post@EaEndsOf24FtGirderTr... CODE: 2018 International Building Code <br /> MEMBER TYPE: COLUMN NDS: 2018 NDS <br /> MATERIAL Solid Sawn <br /> Hem-Fir No.2 (1)5.5 X 5.5 DRY <br /> . . '• . • • •' yfft � ' E <br /> L I <br /> I 8. <br /> Start(ft)0 End(ft):8 <br /> Area Ix ly BSw Lams G Kcr <br /> (ink (in`) (in") (Ibf/ft) Creep Factor <br /> 30.25 76.26 76.26 5.97 1 0.43 1 <br /> Fb(psi) Ft(psi) Fv(psi) Fc(psi) Fc1(psi) E(psi)X103 Emin(psi)x10' <br /> Base Values 575 375 140 575 405 1100 400 <br /> Adjusted Values 57S 375 140 575 40S 1100 400 <br /> CM 1 1 1 1 1 1 1 <br /> CT 1 1 1 1 1 1 1 <br /> Ci 1 1 1 1 1 1 1 <br /> CF 1 1 1 1 1 1 1 <br /> Bending Adjustment Factors C fu=1 Cr=1 <br /> IWONUMIMONT <br /> Unbraced Length(ft) Column End <br /> Span Length(ft) X Y Offset CP Ke(X Axis) Ke(Y Axis) KeUd(X Axis) KeUd(Y Axis) <br /> 1 8 10 10 0 0.78 1.00 1.00 21.82 21.82 <br /> . . NEW <br /> PASS/FAIL MAGNITUDE STRENGTH LOCATION(ft) LOAD COMBO DURATION FACTOR CD <br /> Compressive Stress(psi) PASS(26.3%) 297.S 403.8 0 D 0.9 <br /> • Units for V.Ibf Units for M:Ibf-ft <br /> Z axis DEAD LIVE LIVE ROOF SNOW WIND+ WIND- SEISMIC+ SEISMIC- ICE RAIN EARTH <br /> A 9001 0 0 0 0 0 0 0 0 0 0 <br /> B 0 0 0 0 0 0 0 0 0 0 0 <br /> Reaction Location <br /> A 8- <br /> WILSITMIRW <br /> Type Left Magnitude Right Magnitude Load Start(ft) Load End(ft) Load Type Direction <br /> Point(Ibf) -8953 - 8 - Dead Z <br /> Self Weight(Ibf/ft) 5.97 5.97 0 8 Dead Z <br /> PROJECT:Carlisle Residence 2018 International Building Code ASD <br />