My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 13TH ST 2025 Plans 2025-09-16
>
Address Records
>
13TH ST
>
1700
>
Plans
>
1700 13TH ST 2025 Plans 2025-09-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2025 1:19:11 PM
Creation date
9/16/2025 1:18:47 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1700
Permit
E2504-122
Year
2025
Notes
ELEC FOR Prov Colby D5-D10 Stair 1 and 2 exit signs
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 3 4 5 6 7 <br /> V <br /> 4J uo <br /> GENERAL NOTES: <br /> � gm <br /> 1. ALL FAULT CURRENTS SHOWN REPRESENT SIMULATED 30 <br /> BOLTED FAULTS UNLESS OTHERWISE NOTED.SEE FLAG <br /> NOTE FOR EXCEPTION. z o o$ <br /> N3 p aR <br /> ^m tGo� <br /> F <br /> �O 2, Lorno <br /> 3 g av <br /> FLAG NOTES: a > <br /> (1)2'RO FOR CONTROL,(1)1'RO FOR DATA ROUTED WITH H <br /> REFER TO SHEET E8.11 REFER TO SHEET E8.04 GENERATOR POWER FEEDER. <br /> FOR CONTINUATION FOR CONTINUATION [Z:---CABLE TERMINATIONS AND JUNCTION MODULES IN ELECTRICAL <br /> n n TERMINATION ROOM. <br /> TO ATS-X3 TO ATS-C3 SPARE TO ATS-E3 11,624 TO ATS-X4 TO ATS-C4 TO ATS-E4 SPARE RACEWAY SAME SIZE AS FOR FEEDER,ROUTED'NTH <br /> THE FEEDER RACEWAY. <br /> 1 SA ®GROUND FAULT INDICATION ONLY. <br /> 2000/2240/25©KVA, SA 2000/2240/250000 KVA, ©FAULT CURRENT REPRESENTS SIMULATED SINGLE LINE TO <br /> 4 4 4 4 KNAN/KNAN-65/KNAF KNAN/KNAN-65/KNAF GROUND BOLTED FAULT.SLG FAULT VALUE HIGHER THAN 30 <br /> T <br /> 416OV:480Y/277 - - 416OV:480Y/277 L800AF"11600AF' <br /> 44 � 4 4 BOLTED FAULT AT THIS BUSS.800AF ci 1600AFci 1600AF ci 2000AF 30,4W,5.75%Z 600AS 600AS 30,4W,5.75%Z )..(11600AF �2000AF225AT 1000A 1000AT 2C T 450AF 450AF 225AT / 1600AT i cam' OOOAT cl 2000AT c' ©SURGE ARRESTERS AT GENERATOR TERMINAL CABINET. <br /> 0 <br /> (1)4"SPARE RACEWAY ROUTED WITH FEEDER RACEWAY. U <br /> 310A30 <br /> �' SQUARE D TYPE NW-L MASTERPACT BREAKER. <br /> N 8 8 8 3000AT 3?�jO 33000AT 8 8 N <br /> a ©PROVIDED WITH LOCKOUT TRIPS TO BREAKERS. <br /> 1®TRANSFORMER EQUIPPED WITH PROVISIONS FOR FUTURE FANS I g <br /> TO PROVIDE KNAF RATING. <br /> EUS-H3 HOSPITAL EMERGENCY POWER EUS-H4 HOSPITAL EMERGENCY POWER <br /> 3000A BUS(ROOF LEVEL-NORTH) 3000A BUS(LEVEL 4-SOUTH) Im <br /> 4.16kV//480Y/277V 30 4W 4.16kV//480Y/277V 30 4W <br /> 65,000 AIC @ 480V 65,000 AIC @ 480V <br /> SERVICE ENTRANCE RATED SERVICE ENTRANCE RATED <br /> E <br /> ::2ED<j 2E <br /> 0 <br /> O <br /> N <br /> TO D_WING FIRE PUMP. sly <br /> TO PANEL GAEHDP IN PARKING GARAGE. SEE SHEET E8.02 FOR <br /> REFER TO SHEET E8.07 GARAGE POWER RISER FOR CONTINUATION. REFER TO SHEET E8.02 CONTINUATION. <br /> FOR CONTINUATION FOR CONTINUATION <br /> n n TO PARKING GARAGE FIRE <br /> PUMP.SEE GARAGE POWER m <br /> TO ATS-XI TO ATS-CI TO ATS-Et TO ATS-X2 TO ATS-C2 TO ATS-02 TO ATS-E2 RISER FOR CONTINUATION <br /> E <br /> S A <br /> 1. <br /> 3000/3360/37750KVA, � � <br /> PM <br /> oKNAN/KNAN KNAF 3000/3360/3©KVA, <br /> KNAN/KNAN KNAF <br /> 4160V:480Y/277 <br /> 800AF ,4W,5.75%Z 600AS 600AS 30,4W,5.75%Z 800AF 1600AF 2000AF 3200AF 3200AFG I G G� 00AF 1225AT 1600A 2000AT 3000AT 600AT 225AT " 1600AT 200AT 300AT 3800AF 8 OAF <br /> 0OAT 2000AT <br /> M ? -0 <br /> I "' <br /> U <br /> " 8 8 ;�A eh10^ °,2�R 5°00A 8 B B Permit/Seal <br /> " t A <br /> D _ G � ���p WAS���� <br /> EUS-H1 HOSPITAL EMERGENCY POWER EUS-H2 HOSPITAL EMERGENCY POWER <br /> REFER TO SHEET E8.21 REFER TO SHEET E8.22 5000A BUS(LEVEL B-NORTH) SOOOA BUS(LEVEL B-SOUTH) <br /> A <br /> FOR CONTINUATION FOR CONTINUATION 4.16kV//48OY/277V 30 4W 4.16kV//480Y/277V 30 4W �0, F'c sTEe' <br /> 65,000 AIC @ 480V 65,000 AIC @ 480V SIONAL F.N <br /> SERVICE ENTRANCE RATED SERVICE ENTRANCE RATED 04/16/2025 <br /> TO <br /> T-ES1 TO TO TO PARALLEL <br /> (750KVA 750KVA CANCER GENERATOR 3E1 3E2 <br /> HOSPITAL <br /> XFMR) XFMR CENTER SWBD#1 <br /> 3 <br /> REFER TO CUP POWER RISER CENTRAL PLANT <br /> F1 13,822 ILL LISTED LESS-FLAMMABLE TO CUP FIRE PUMP, FOR CONTINUATION <br /> SEE CUP POWER n <br /> FLUID FILLED ENVIROTEMP RISER FOR <br /> A4M3 A4M3 A2M4 A4M4 TYPICAL ALL EMERGENCY CONTINUATION TO ATS-P1XH1 TO ATS-PIEHDPI TO ATS-PMOHDPI <br /> POWER UNIT SUBSTATIONS <br /> PM SA SA <br /> 2500/2800/3125KVA, SPACE SPACE SPACE SPARE SPARE SPACE <br /> KNAN/KNAN-65/KNAF 4 4 4 4 4 4 <br /> 2500 3125KVA KNp,�1[KNAF 416OV:480Y/277 PM <br /> / 1 A <br /> 1600AF 1600AF 800AF 1600AF /4160V�80Y/2 7V 600 Ag 600AS 30,4W,5.75%Z 800AF n 800AF 800AF 800AF n 1600AF 3200AF n 1600AF 800AF 4000AF 800AF n <br /> ( SPARE ( SPARE ( SPARE ( SPARE 1200AT ( 1200AT 600AT 1200AT 30 4W 5.75%Z 450AF 500AF 125AT ° 225AT 01 1200AT cI o ci 2500AT c' <br /> ^ u u u u <br /> :�:N 8 8 8 8 44000AT 4000AT <br /> G <br /> EUS-EH1 HOSPITAL EMERGENCY POWER EUS-CP1 C.U.P EMERGENCY POWER <br /> 4000A BUS(EXISTING HOSPITAL) 4000A BUS(CENTRAL UTILITY PLANT) 40,515 <br /> 4.16kV//480Y/277V 30 4W 4.16kV//480Y/277V 30 4W <br /> 65,000 AIC @ 480V 65,000 AIC @ 480V <br /> SERVICE ENTRANCE RATED SERVICE ENTRANCE RATED <br /> F1 3E1 3 3E2 ::F ® <br /> V) <br /> PROVISION FOR FUTURE PROVISION FOR FUTURE <br /> 3 3 Q <br /> 1000:5 3 MPR MPR 3 1000:5 (� <br /> 1000:5 3 3 1000:5 >_ <br /> 3 1000:5 1000:5 m <br /> '1000:5 1000:5 J <br /> fN <br /> 3MFP 1F. <br /> fN <br /> fNj <br /> 3O <br /> z86 86 1000:5 1000:5 U <br /> SPACE G EMA-1 NG EMA-2 TIE G EMB-2 EMB-1 n SPACEB 200AF 52 350AT 52 SOOAT Q9 2 OA 52800AT SOOAT 1200AF W <br /> u 1200AF 1200AF1200AF 1200AF u <br /> 3 523 W <br /> 1206.5 NI 1200:5 <br /> W <br /> 13,945 13,945 W <br /> F_ <br /> MFP 3 3 MFP 3 MFP 3 3 Z <br /> MiP W <br /> U <br /> PMVS-CP GEN-1 GEN-2 GEN-3 GEN-4 GEN-FUT -� <br /> PARALLELING MEDIUM VOLTAGE 52 1200AF 52 1200AF 52 1200AF 52 1200AF 52 1200AF U <br /> SWITCHGEAR-CENTRAL PLANT <br /> 5 KV,2000A BUS 0 <br /> Lu <br /> 4.16KV-30+GND <br /> 40KA SYM. 3 3 3 3 3 J <br /> I <br /> Z <br /> F F F F O <br /> C/O 3 <br /> F F F F � <br /> �V°ClI �V°Cll �V°Cll w w t <br /> S� S� S� S� '�SAq Z w <br /> L L J Cuj <br /> TYPICAL GENERATOR J ) 0 Z <br /> 2000KW O.SPF 4160V, d > <br /> 30,4W G4 G3 I <br /> G3 G5 FUTURE <br /> GENERATOR o <br /> A #t/o 5kv #t/o skv #t/o 5kv #t/o 5kv Project No.:204822968 <br /> MV-105 CU. MV-105 CU. MV-105 CU. MV-105 CU. <br /> N R 100SEC. " R 400SEC. 05EC. " R 100SEC. �OOSEC. SCgIe:NONE <br /> #1/0 600V #1/0 600V #1/0 600V #1/0 600V MEH MEH NCA 2025.o4.16 <br /> XHHW CU. = XHHW CU. = XHHW CU. = XHHW CU. _ Dw Dsgn. Chkd. YYYY.MM.DD <br /> Title <br /> PRIMARY POWER RISER DIAGRAM-EMERGENCY SYSTEM PRIMARY POWER <br /> RISER DIAGRAM <br /> EMERGENCY SYSTEM <br /> 8 L City of Everett Permit Services Drawing No. <br /> EVERETT Reviewed for Permit 04/22/2025 •0 <br /> ORIGINALSHM IRCHE <br />
The URL can be used to link to this page
Your browser does not support the video tag.