Laserfiche WebLink
1 2 3 4 5 6 7 <br /> REFER TO E8.07 V <br /> ELECTRICAL EQUIPMENT IDENTIFICATION LEGEND GENERAL NOTES: Q� u <br /> T F 1 N H 1 THESE NOTES APPLY TO ENTIRE POWER RISER,SHEETS E8.02 THRU E8.11 V o <br /> } _ o°�o <br /> o <br /> PANEL NUMBER 1.ALL FAULT CURRENTS SHOWN REPRESENT SIMULATED 30 BOLTED FAULTS AaQ <br /> UNLESS OTHERWISE NOTED.SEE FLAG NOTE FOR EXCEPTION. pR= <br /> VOLTAGE 9 <br /> H-480Y/277V 4J °g m 2 <br /> L-208Y/120V c <br /> HOP-480Y/277V DISTRIBUTION <br /> SYSTEM a o°4FLOOR <br /> N-NORMAL BRANCH <br /> F R ROOFTOP C-CRITICAL BRANCH m o o@ p€ <br /> X-LIFE SAFETY BRANCH -0 g a° <br /> y° LEVE�9 E-EQUIPMENT BRANCH FLAG NOTES: E J-51 s sv <br /> 8-LEVEL 8 0-OPTIONAL BRANCH THESE NOTES APPLY TO ENTIRE POWER RISER,SHEETS E8.02 THIRD E8.11. H €t€ <br /> 7-LEVEL 7 U-UPS BRANCH <br /> 6-LEVEL 6 D:�::-FEEDER SCHEDULES APPLY TO ALL FEEDERS BELOW 600 VOLTS.UTILIZE THIS <br /> 5-LEVEL 5 SCHEDULE FOR RISERS SHOWN ON SHEETS E8.02 THRU E8.13 AND E8.20. <br /> 4-LEVEL 4 <br /> 3-LEVEL 3 FAULT CURRENT REPRESENTS SIMULATED SINGLE LINE TO GROUND BOLTED <br /> AJ4 2-LEVEL 2 FAULT.SLG FAULT VALUE HIGHER THAN 30 BOLTED FAULT AT THIS BUSS. <br /> 1 -LEVEL 1 <br /> G-GROUND LEVEL >-#6 AWG BONDING JUMPER BETWEEN PANELS SERVING PATIENT CARE AREAS <br /> B-BASEMENT LEVEL ON THIS LEVEL <br /> BUILDING <br /> D-CANCER CENTER <br /> F-D-WING <br /> G-PARKING GARAGE <br /> TYPE P-UTILITY PLANT o <br /> T-TRANSFORMER <br /> L-LIGHTING CONTROL PANEL SCHEDULE NOTES: o <br /> U <br /> 1. CONDUIT SIZING BASED ON RIGID GALVANIZED STEEL OR PVC SCH.40 <br /> CONDUIT AND WIRE TYPE THHN/THWM-2 OR XHHW WIRE,TAKING INTO <br /> ACCOUNT BOTH CONDUIT FILL AND JAMB RATIO. CONDUIT AND RACEWAY <br /> E <br /> FOR ALUMINUM CONDUCTORS(AI)SIZED FOR COMPACT TYPE CONDUCTORS. <br /> CONFIRM CONDUIT FILL AND JAM RATIOS FOR FEEDER CONFIGURATIONS <br /> ATK225 OTHER THAN THOSE SHOWN. I< <br /> AL5 T-F2EL1 2. AMPACITIES LISTED ARE BASED ON THE FOLLOWING TAKEN FROM TABLE <br /> A2J5 75 KVA <br /> AP3 310-16. <br /> T-FBNL1 ka AT75 4830 208Y/120V Im <br /> 225 KVA pip <br /> 9402 0� 4W A.75'RATING FOR 3W AND 4W FEEDERS. <br /> 4830 208Y/120V B.90'RATING FOR 5W FEEDERS DE-RATED TO 80%WHERE PREDOMINATELY <br /> E AL5 PANEL K 13 RATED DIST. PANEL PANEL PANEL PANEL HARMONIC CURRENTS ARE PRESENT.NEUTRALS 2/1/0 ARE <br /> FT3NH7 PANEL FBNL2 FBNL3 FBNL4 FBNL5 - PARALLELED ON 5W FEEDERS. <br /> FBNL1 400,E <br /> 225AT 3. INCREASE RACEWAY SIZE FOR OTHER TYPES OF RACEWAYS AND DIFFICULT <br /> OR LONG PULLS. <br /> C <br /> 4. GROUND WIRE SIZE INCREASED FOR PARALLEL CONDUCTOR RUNS PER NEC <br /> ��a S Oy9 CC4 TABLE 250-122. <br /> AILS PANEL <br /> FBNL11 CC3 <br /> "s <br /> T-FBEL1 z I a <br /> 11-F KVA ` a <br /> 4BOV 208Y/120V <br /> 30 4W Vc <br /> K-13 RATED <br /> o AG3 ATK112 06 A2J5 <br /> 225 KVA ,�% �� 40OA/3P <br /> AP3 r <br /> 480V 208Y/120V PANEL <br /> PANEL <br /> PANEL 30 4W DIST. PANEL o <br /> K-13 RATED <br /> FBCH1 FBCL1 ALS �� AP4 A2M41 CP-1 EF-4 FCU-B03 FCU-B04 FCU-B05 SP-1 0 <br /> CC4 a�i <br /> AJ4 ¢ a a A2J5 63 U <br /> N 2 <br /> m ^o ATK225 m m Paa3 Permit/Seal <br /> LTG PANEL a a o <br /> LCP-BN <br /> A2M4 3000A BUSWAY A n. <br /> D AJ4 ti p4 WAS C,t� <br /> p��� <br /> PANEL <br /> z� <br /> FBCHDPI PANEL <br /> d d d d d d11600AFM d d FBEH1 A�oFFc sTEe-� F¢. <br /> PANEL AFFECTED ( 1600AT ( 600AT ( 1775AT ( 1775AT SPARE ( SPARE ( SPARE SPACE SPACE SPACE SPACE SPACE SPACE ( SPARE ( SPARE ( SPARE ( 400AT ( 600AT( �`'' ( 3000AT ( 1/5AT ( 20ATF ( 50ATF ( 20ATF ( 20ATF ( 20ATF ( 20ATF( 1225AT( SPARE SPARE SPACE SPACE( p00AT �sS7gVA1.'GNp� <br /> 04/i6/2025 <br /> BY THIS PROJECT 6 <br /> ry�k <br /> AJ4 A5N4 FBCHDPI FBNHDPI FBEHDPI <br /> 1600A 480Y/277V,30,4W 1600A 480Y/277V,30,4W 3000A 480Y/277V,30,4W <br /> 65,000AIC 100,000AIC 100,000AIC <br /> ATS-X1 ATS-C1 ATS-E1 <br /> 80OA/4P 1600A/4P 3000A/4P <br /> LIFE SAFETY CRITICAL EQUIPMENT <br /> 37,515 KAIN4 <br /> 30,454 4 sp2 <br /> 67,256 <br /> 2 41,933 , � FEEDER SCHEDULE <br /> FEEDER NO. CONDUCTORS(COPPER AND COMPACT ALUMINUM) AMPACITY <br /> r CXX=Cu AXX AI <br /> CONDUIT WIRE NOTE 2 <br /> 3 } = <br /> AJ4 A5N4 m AJ4 A5N4 CA4 1-1/4" 4-/4,1#8 G. 85 <br /> a m CA3 1' 3-$4,1'8 G. 85 <br /> g a� CB4 1-1/4" 4-/2,1 gs G. 115 <br /> C n CB3 1-1/4" 3-/2,1/6 G. 115 <br /> CC5 2" 3-P,2#1/0 N,1#6 G. 120 <br /> CC4 1-1/2" 4-gl,1 p6 G. 130 <br /> LS CR NORMAL EQ LS CR EQ CC3 1-1/2" 3-gl,16 G. 130 <br /> AF5 2" 5-#3/0,1 #4 G. 140 <br /> AF4 2' 4-#3/0,1#4 G. 155 <br /> REFER TO SHEET E8.00 REFER TO SHEET E8.01 <br /> FOR CONTINUATION HOSPITAL POWER RISER DIAGRAM-LEVEL B-NORTH WING FOR CONTINUATION AF3 1-1/2 3-/3/0,1 g4 G. 1 <br /> acs 2-1/2"' s-g4/0,1 pa G. 164sa <br /> SCALE: NONE AG4 2- 4-#4/0,1 g4 G. 180 <br /> AG3 2" 3-#4/0,1 g4 G. 180 <br /> AH5 2-1/2" 5-250kcmil,1 /4 G. 184 <br /> AH4 2-1/2' 4-250kcmil,1 /4 G. 205 <br /> AH3 2- 3-250kcm1,1 /4 G. 205 <br /> CH5 3" 5-250kcm1,1 /4 G. 232 <br /> AJ5 3' 5-300kcmil,1 /4 G. 204 <br /> AJ4 2-1/2" 4-300kcmil,1 #2 G. 230 <br /> AJ3 2" 3-300kcmil,1 #2 G. 230 <br /> AK5 3' 5-350kcmil,1 /2 G. 224 V) <br /> AK4 2-1/2" 4-350kcmil,1 /2 G. 250 <br /> AK3 2-1/2" 3-350kcmil,1 #2 G. 250 <br /> AL5 3" 5-400kcmil,1 #2 G. 244 Q <br /> AL4 3" 4-400kcmil,1 /2 G. 270 U <br /> AL3 2-1/2' 3-400kcmil,1 /2 G. 270 >- <br /> 1 TRANSFORMER SECONDARY FEEDER SCHEDULE AM5 3 1/2' 5-500kcmil,1 #2 G. 280 m <br /> 480 TO 2081 THREE PHASE TRANSFORMERS AM4 3" 4-500kcmil,1 #2 G. 310 O <br /> SECONDARY CONDUCTORS(COPPER AND COMPACT ALUMINUM) GROUNDING NDU AM3 3" 3-500kcmil,1 /2 G. 310 UB NO. kTI ELECTRODE CONDUCTOR AN4 3-1/2" 4-600kcmil,1 #1 G. 340 <br /> CXX=Cu AXX=AI RATING FLA CONDUIT ORE CONDUCTOR NDUCITY <br /> CT3 3 8 1 2" 4- 2,1#8 G. 8 20 AN3 3" 3-600kcmil,1 #1 G. 340 Lu <br /> CT6 6 17 3 4" 4- 10,1#8 G. 8 30 W <br /> CT9 9 25 3 4" 4- ,1 G. 8 50 A2G3 (2)2-1/2' 3-/4/0,1 #IG EA. 360 > <br /> CT15 15 42 1" 4- 1 G. 8 65 LLJ <br /> CT30 30 83 1 1 2' 4- 2,1#8 G. 8 115 AP4 4" 4-750kcmil,1 /1 G.EA. 385 0� <br /> AT45 45 125 2" 4- 0,1#4 G. 4 155 AP3 3-1/2' 3-750kcmil,1 /1 G.EA. 385 LLJ <br /> AT75 75 208 2-1 2' 4-300kcmil,1 1 0 G. 1 0 230 A2J5 (2)3" 5-300kcmil,1 #1 G.EA. 408 Z <br /> AT112 112.5 312 3-1/2- 4-600kcmil,1 0 G.EA. 3 0 340 A2K5 (2)3' 5-350kcmil,1 #1/0 G.EA. 448 Lu <br /> AT150 150 416 2 2-1 2" 4-300kcmil,1 0 G.EA. 3 0 460 A2K4 (2)3' 4-350kcmil,1 /1/0 G.EA. 500 U <br /> AT225 225 625 2 3- 4-600kcmil,1 0 G.EA. 4 0 680 A2K3 (2)2-1/2' 3-350kcmil,1 /1/0 G.EA. 500 'J <br /> AT300 Nm 833 4 3- 4-350kcmil,1 0 G.EA. 4 0 1000 Q <br /> A2M4 (2)3' 4-500kcmil,1 /3/0 G.EA. 620 <br /> AT500 500 1388 5 3-1/2' 4-600kcmil,1 kcmil G.EA. 250 1700 U <br /> A2M3 (2)3' 3-500kcmil,1 /3/0 G.EA. 620 <br /> 480 TO 20BY 120V,THREE PHASE TRANSFORMERS(K-Rated) A2N4 (2)3-1/2" 4-600kcmil,1 /3/0 G.EA. 680 Lu <br /> SECONDARY CONDUCTORS(COPPER AND COMPACT ALUMINUM) GROUNDING A21,13 1 (2)3" 3-600kcmil,1 J3/0 G.EA. 680 <br /> kVA ELECTRODE CONDUCTOR <br /> CXX=Cu.AXX=AI RATING FLA CONDUIT MRE CONDUCTOR AMPACFIY A314 (3)3" 4-400kcmil,1 /3/0 G.EA. 810 Q z <br /> A3L3 (3)2-1/2' 3-400kcmil,1 #3/0 G.EA. 810 '^ <br /> CTK3 3 8 1 2" 3- 2,1 N.1 G. 8 20 Z `J <br /> CTK6 6 17 3 4' 3- 0,1#6 N,1#B G. 8 30 A31,14 (3)3-1/2" 4-600kcmil,1 14/0 G.EA. 1020 O <br /> CTK9 9 25 1" 3- ,1#4 N.1#8 G. 8 44 Cn Q <br /> CTK15 15 42 1 1 4- 3- ,1 1 N.1 G. 8 60 A3N3 (3)3" 3-600kcmil,1 /4/0 G.EA. 1020 (D <br /> CTK30 30 83 1 1 3- 2,1 4 0 N,1 G. 6 104 <br /> A4M4 (4)3" 4-500kcmil,1 350 G.EA. 1240 Lu ~ <br /> Y 3 <br /> ATK45 45 125 2 1 2' 5- 0,1 2 G. 2 164 A4M3 (4)3" 3-500kcmil,1350 G.EA. 1240 Lu x w <br /> LLJATK75 75 208 3" 5-350kcmll,1 0 G. 1 0 224 C4N4 (4)4' 4-600kcmil,1-250kcmil G.EA. 1680 U w <br /> ATK112 112.5 312 5" 5-750kcmil,1 0 G.EA 3 0 348 Z w <br /> ATK150 150 416 2 5-500kcmil,1 0 G.EA 4 0 560 A5N4 (5)3-1/2" 4-600kcmil,1 #400 C.EA. 1700 Lu <br /> A5N3 5 3" 3-600kcmil,1 #400 G.EA. 1700 °1 _ z ~ <br /> ATK225 225 625 2 5" 5-750kcmil,1 0 G.EA. 4 0 696 0 = <br /> ATK300 1 300 1 833 4 3-1/2- 5-500kcmil,1 250kcmil G.EA. 250 1120 A6N4 (s)3-1/2' 4-600kcmil,1600 G.EA. 2040 > <"> <br /> ATK500 1 500 1 1388 6 4" 5-600kcmil,1#500kmil G.EA. 250 1848 A6N3 (6)3' 3-600kcmil,1 #600 G.EA. 2040 o0 <br /> CJ CL 0 <br /> A Project No.:204822968 <br /> Scale:NON E <br /> e MEH MEH NCA 2025.04.16 <br /> D- Dsgn. Chkd. YYYY.MM.DD <br /> Title <br /> LEVEL 82 D-WING POWER RISER <br /> DIAGRAM LEVEL 132 <br /> 06 <br /> NORTH WING <br /> 8 L City of Everett Permit Services Drawing NO. <br /> , $ EVERETT Reviewed for Permit 04/22/2025 E8•07 <br /> ORIGINALSHM IRCHE <br />