My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11311 19TH AVE SE CLUBHOUSE 2025 Plans 2025-09-16
>
Address Records
>
19TH AVE SE
>
11311
>
Plans
>
11311 19TH AVE SE CLUBHOUSE 2025 Plans 2025-09-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2025 2:51:22 PM
Creation date
9/16/2025 2:49:23 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
11311
Unit
CLUBHOUSE
Permit
M2501-041
Year
2025
Notes
MECHANICAL - Tenant Improvement Clubhouse INTERIOR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Everett Permit Services <br /> EVERETT Reviewed for Permit 01/30/2025 <br /> D. Mantel, Wall Projections, & Hearth Mantels or Wall Projections - Non-Combustible <br /> Extensions <br /> WARNING! Risk of Fire! Comply with all minimum clear- <br /> ances to combustibles as specified. Framing or finishing <br /> f 12 in. > <br /> material closer than the minimums listed must be construct- <br /> ed entirely of noncombustible materials (i.e., steel studs, <br /> concrete board, etc). <br /> 1/4 in.gap <br /> 6 in. <br /> Clearance to combustible material under the insert is 114 12 in. <br /> inch (6 mm). *B <br /> • Use leveling legs to raise insert minimum 114 inch (6 <br /> mm)above combustible material or outer wrap of factory <br /> built firebox. <br /> SURROUND <br /> Combustible facings must not extend behind the insert OPENING <br /> surround. For non-combustible material specifications 'SEE TABLE <br /> refer to Section 1.E. 1 or 2 <br /> Mantel Legs or Wall Projections <br /> Combustible <br /> ® Note: Measurement is taken from top of the surround <br /> TOPVIEW opening. <br /> Figure 3.14 Minimum Vertical and Maximum Horizontal <br /> w Dimensions-Non-Combustible <br /> 114 in.GAP INTERIOR WALL <br /> ® Unit Size Surround A B <br /> Model <br /> sE in. t M125-3523 17-15/16 in. 6-1/16 in. <br /> �— 12in.—• c 25 in. M125-3726 18-15/16 in. 9-1/16 in. <br /> — M125-3928 19-15/16 in. 11-1/16 in. <br /> 18in. M130-4027 20-7/16 in. 6-9/16 in. <br /> 30 in. M130-4230 21-7/16 in. 9-9/16 in. <br /> SURROUND OPENING M130-4432 22-7/16 in. 11-9/16 in. <br /> MANTEL LEG OR WALL PROJECTIONS M135-4229 21-7/16 in. 5-1/16 in. <br /> 35 in. M135-4432 22-7/16 in. 8-1/16 in. <br /> ® Non-Combustible M135-4832 24-7/16 in. 8-1/16 in. <br /> TOP VIEW <br /> Table 1 Mantel Leg or Wall Projection Minimum Dimension <br /> x x needed when Installing a Standard Surround <br /> INTERIOR WALL <br /> 114 in.Gap Unit Front Model A B <br /> ® ® ® Size <br /> T INFIT 14-5/16 in. 1-1/4 in. <br /> sin. 25 in. <br /> ` A FS-MI, IA-MI, HARC-MI 16-1/16. 2-1/2 in <br /> "SEE TABLE 12 in. <br /> 1 or 12 in.—> 30 in. INFIT 16-13/16 in. 1-1/4 in. <br /> FS-MI, IA-MI, HARC-MI 18-9/16 in. 2-1/2 in <br /> INFIT 19-5/16 in. 1-1/4 in. <br /> lam. 35 In. <br /> FS-MI, IA-MI, HARC-MI 21-1/16 in. 2-1/2 in <br /> I <br /> Table 2 Mantel Leg or Wall Projection Minimum Dimension <br /> SURROUND OPENING MANTEL LEG OR needed when Installing a Custom Surround. Front Model <br /> WALL PROJECTIONS Determines the Minimum Size of the Custom Surround <br /> Figure 3.13 Clearances to Mantel Legs or Wall Projections Note:All numbers in Tables 1 and 2 include the 1/4 in. gap on <br /> (Acceptable on both sides of surround opening) surround edge. <br /> Heat&Glo • SUPREME-125-IFT,SUPREME-130-IFT,SUPREME-135-IFT Installation Manual • 2532-980 Rev. F • 5/19 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.