Laserfiche WebLink
Permit#: FA2503-015 <br /> Site Address: 3003 W Casino Rd BLDG 40-58 <br /> BOEING BUILDING 40-58 PAINT BOOTH Applicant: EVERON LLC <br /> Application Date:03/28/2025 a <br /> Description: Adding dual monitor modules for Tj <br /> waternow and tampers and Get <br /> Review Date: 04/0 712 0 2 5 O <br /> FIRE ALARM SYSTEM w �U <br /> aZ � <br /> EVERETT LIU Z O <br /> Everett Fire Dept.Permit Review Q j <br /> Status:Approved Q Z J 6 <br /> EVERETT, WA 98204 Reviewed By:kbrown <br /> 04/0 7/2 022 5 1 1:33:24 a) W O LO <br /> AM Q OO Q SHEET INDEX GENERAL NOTES O W w <br /> QTY SYMBOL DESCRIPTION MODEL SUPPLIER MOUNTING o H LU <br /> SHEET NO. DESCRIPTION INSTALLATION&GENERAL WIRING NOTES: NUMBER HEIGHT <br /> FA-01 <br /> TITLE SHEET GENERAL NOTES: REMOTE BOOSTER <br /> 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE E(1) NAC POWER SUPPLY FCPS24-S8 NOTIFIER 66"A.F.F TO <br /> WITH NFPA,LOCAL AND STATE AHJ's,NEC AND CONTRACT E (EXISTING) THE TOP <br /> FA-02 TYPICAL WIRING DETAILS&CALCULATIONS DRAWINGS <br /> 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT <br /> INTENDED FOR ACTUAL CONDUIT ROUTING. <br /> FA-03 LEVEL FIRE ALARM PLAN 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL n O FIRE ALARM PC2WL SYSTEM SENSOR CEILING <br /> CONTRACTOR PER NEC AND AHJ. L O HORN STROBE <br /> 4. VERIFY ALL LOCATIONS OF DEVICES WITH <br /> ELECTRICAL/ARCHITECTURAL PLANS.SCALE AND PLACE ALL <br /> DEVICE PER ELECTRICAL/ARCHITECTURAL PLANS. <br /> 5. ALLCIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR DUAL INPUT FDM NOTIFIER CEILING <br /> OPENS,SHORTS,GROUNDS AND PROPER"END-OF-LINE" <br /> RESISTANCE.EACH CIRCUITS METER READING MUST BE 8 DM MONITOR MODULE _ <br /> DOCUMENTED AND PRESENTED TO THE EVERON FIELD <br /> TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP&CHECKOUT. O <br /> 6. AS-BUILTS: <br /> 6.1. A SET OF INSTALLATION AS-BUILT DRAWINGS SHOWING EXISTING TO VERIFY IN O <br /> ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT ... m <br /> ADDING DUAL MONITOR MODULES FOR WATERLOW AND TAMPERS AND BY PROJECT FOREMAN FOR USE BY THE EVERON REMAIN FIELD LOCATION <br /> CEILING MOUNT HORN/STROBES IN FC ROOMS. TECHNICIAN. <br /> 6.2. AS-BUILTS SHALL BE KEPT ORDERLY AND BE CLEARLY RELOCATE EXISTING VERIFY IN L 7 O <br /> MARKED WITH DIFFERENT COLOR PENS FOR EACH CIRCUIT RE W <br /> AND/OR CIRCUIT TYPE AND LABELED PER THE WIRE LEGEND. ... ... <br /> AS-BUILTS MUST INDICATE CHANGES TO THE FINAL DEVICE DEVICE FIELD LOCATION Q N <br /> INSTALLED LOCATIONS IF NOT INSTALLED AT LOCATION /^ N 00 <br /> SHOWN ON DESIGN DOCUMENTS. 00 >- 0 Ci) <br /> 6.3. AS-BUILT REDLINES NOT PROVIDING THIS INFORMATION WILL A.F.F ABOVE FINISHED VERIFY IN O Q BE RETURNED TO THE INSTALLATION CONTRACTOR FOR ... ... U7 > I— <br /> CORRECTION.EVERON IS NOT RESPONSIBLE FOR THESE FLOOR FIELD LOCATION O Z <br /> W <br /> DELAYS. W'^ <br /> 7. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS I vJ W <br /> WILL BE MADEWITH THE EVERON PROJECT MANAGER. END OF LINE VERIFY IN (D < Q _ <br /> 8. ALL EVERON FIELD SERVICES MUST BE SCHEDULED WITH THE <br /> EVERON PROJECT MANAGER WITH A MINIMUM OF 14 WORKINGS RESISTANCE -" -" FIELD LOCATION \J W <br /> DAYS ADVANCE NOTICE. Z J M W <br /> Q W <br /> 9. DO NOT INSTALL LINE VOLTAGE IN SAME CONDUIT AS POWER 0 Q � J <br /> LIMITED CABLES. J W O W <br /> LEGENDS W M > H <br /> m LL W <br /> Z_ <br /> W <br /> APPLICABLE CODES O <br /> m <br /> NFPA 72 2019 EDITION <br /> IBC 2018 EDITION WITH WASHINGTON AMENDMENTS <br /> NFPA 70(NEC)2017 EDITION <br /> SCOPE OF WORK <br /> Z <br /> CODE INFORMATIONS <br /> s �: ;:: <br /> WIRE DESIGNATION o 0 0 0 <br /> SYMBOL CIRCUITTYPE DESCRIPTION <br /> �• _ I aaaaa <br /> ' ri7 t � .• - - ,��a O Fill D SLC ADDRESSABLE LINE 16/2AWG FIRE RATED CABLE <br /> :a{S O Q>9SI : 11 -p e t S STROBE CIRCUIT 14/2AWG FIRE RATED CABLE <br /> V PREPARED APL <br /> REVIEW RM <br /> — } <br /> - F - - I-• y•r MMIDDIYI' 12/21122 <br /> O;• ra!' '� -J�a ". SCALE NOT TO SCALE <br /> T— Gs <br /> f ' <br /> JOB NO. 501209854 <br /> :Iy NOTES: <br /> O - a Drawing PreparedlReviewed by: <br /> • O "STRIPES ARE NOT REQUIRED,HOWEVER IT DOES MAKE IT EASIER FOR CIRCUIT IDENTIFICATION. <br /> Daniel J.Kelso <br /> • 0 -n,O 1.WIRE MANUFACTURER IS FOR REFERENCE PURPOSE ONLY.WHEN USING OTHER MANUFACTURE,ENSURE PROPER CROSS REFERENCE <br /> NICET Certification#149793 <br /> ® 2.FPLP CAN BE USED IN MOST ALL APPLICATIONS WITH THE EXCLUSION OF WET AND CIRCUIT INTEGRITY REQUIREMENTS Fire Alarm Systems-Level III <br /> O 3-INSTALL WIRING PER NEC.USE CABLE TYPE CONSISTENT WITH NEC REQUIREMENTS,IE:PLENUM,RISER,UNDERGROUND,ETC. <br /> Expiration: 2028-03-01 <br /> VICINITY MAP <br /> SHEET FA-01 <br /> 0 2024 Everon.All rights reserved.The product/se es listed in this document are marks and or registered marks of their respective owners and used under license.Unauthorized use strict) prohibited. <br />