3003 W CASINO RD 2025 BLDG 40-58 Plans 2025-09-17
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2025 BLDG 40-58 Plans 2025-09-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2025 8:58:41 AM
Creation date
9/17/2025 8:58:32 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
FA2503-015
Year
2025
Notes
ADDING DUAL MONITOR MODULES FOR WATERLOW AND TAMPERS AND CEI
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIGNATURE DATA LOOP WIRING.CLASS B ONLY SIGNATURE DATA LOOP.CLASS B ONLY <br /> RECORD DRAWINGS a CLASS A OR B NOTIFICATION WIRING � ;o <br /> SL TA rl rl To—IL°°ATA I'I L0-S rl To.- LU 0 U <br /> coop fie c-I I <br /> r- l r I-I oewce coop w al_ --- _c-I Device > <br /> AS-BUILT/RECORD DRAWING REQUIREMENTS: Q Z CD <br /> s s s s s OLU Z O o <br /> THE FOLLOWING INFORMATION SHOULD BE RECORDED ON A SEPARATE SET OF Q Q j <br /> DRAWINGS FOR EACH PROJECT: SERIES PARALLEL WIRING,ACCEPTABLE T-TAPPING AT EVERV DEVICE,UNAC ouT EOL 0 Z _J <br /> w ouT <br /> Device oEvicE oEvicE ___ _____ ______ <br /> 1. ANY CHANGES IN THE LOCATION OF ANY ASSOCIATED FIRE ALARM OR CEPTABLE FACP F r W O to <br /> INTERFACE EQUIPMENT.CONTROL PANELS,ANNUNCIATORS,DETECTORS, OR EOL RESISTOR ON Z N <br /> CONTROL RELAYS,INPUT AND OUTPUT MODULES,TERMINAL CABINETS, NAC I NON ADDRESSABLE Q p O <br /> ETC. 0p II II CIRCUITS O LU <br /> 2. ANY CHANGES TO CIRCUIT WIRING.THIS INCLUDES DELETION OR INou l l O LU > <br /> W <br /> ADDITIONAL WIRING RUNS.ANY RE-ROUTING OF CIRCUIT WIRING.ANY °� ° � I.-ADDITIONS OR DELETIONS TO THE NUMBER,LOCATION,AND ORDER OF s BO s <br /> SLC DATA LI ore sccoATA I'I LOIS ToaE DEVICE DEVICE (n <br /> DEVICE WIRING ON A CIRCUIT. ooPiN la , r- _I-I De Iw LC P N rl_ --- _rl De i I <br /> 3. ADDRESSES AND/OR LABELS FOR ALL ADDRESSABLE DEVICES. tux <br /> 4. CANDELA SETTINGS OF ALL VISUAL NOTIFICATION DEVICES. s CLASS B,STYLE 4 WIRING <br /> 5. WATTAGE TAP SETTINGS OF ALL SPEAKER NOTIFICATION DEVICES. <br /> ANY CHANGES SHALL BE DISCUSSED WITH THE EVERON PROJECT MANAGER <br /> TO ENSURE SYSTEM AND CODE PARAMETERS ARE MET. EVERON SHALL <br /> NOT BE HELD ACCOUNTABLE FOR CHANGES MADE WITHOUT APPROVAL. r-TAPPING,ACCEPTABLE STAR-TAPPING,UNACCEPTABLE <br /> THIS INFORMATION SHALL BE NEAT AND LEGIBLE WHEN PRESENTED TO THE (n <br /> TECHNICIAN AT THE CONCLUSION OF THE PROJECT. PLEASE NOTE CONTACT FACP -j r - r Z <br /> INFORMATION ON DRAWINGS FOR INDIVIDUALS WITH FAMILIARITY OF OR Q <br /> INSTALLATION IN THE EVENT QUESTIONS ARISE DURING THE CLOSEOUT NAC - O <br /> PROCESS. l l O Q <br /> H U <br /> DEVICE DEVICE I Z J <br /> - W -CD Q <br /> L--------------J Q P N V <br /> d) 06 <br /> 00 >- 0Q J <br /> CLASS A,STYLE 6 WIRING Ott < <br /> SEPARATION OF CLASS A CIRCUITS-INSTALLATION EXCEPTIONS: Z Q M W <br /> CLASS A OUTGOING AND RETURN CONDUCTORS,EXITING AND RETURNING C) W O W Z <br /> TO THE CONTROL PANEL,ARE TO BE ROUTED SEPARATELY.THE MINIMUM <br /> RECOMMENDED SEPARATION IS 1 FT.VERTICALLY AND 4 FT. E) ! M W <br /> HORIZONTALLY.THE FOLLOWING EXCEPTIONS STILL DO NOT ELIMINATE m LL <br /> THE 2ND PAIR OF WIRES.THEY ALLOW YOU TO USE A SINGLE RACEWAY J <br /> AND ELIMINATE THE SEPARATION FOR THESE CONDITIONS. Q <br /> Z_ U <br /> 1. WHEN MAXIMUM CABLE,ENCLOSURE,OR RACEWAY IS LESS THAN 10 w <br /> FEET.NO LIMIT TO NUMBER OF DEVICES. d <br /> NAC Circuit Load,Voltage •• Battery Calculations2. UNLIMITED CONDUIT OR RACEWAY DROP TO AN INDIVIDUAL DEVICE. m >_ <br /> APs Name APs-t circuit ldenifers 3. UNLIMITED CONDUIT OR RACEWAY DROP TO A ROOM NOT <br /> Location PORTABLE Pt -Standby: Alarm: Output#1 Ouptul#2 Oulput#3 Ouglut#4 Aux EXCEEDING 1000 SQ,FT.NO LIMIT TO THE NUMBER OF DEVICES. <br /> P.S.Type: FCPS-24S8 00910 0.1450 NACSync NACSync NACSync NACSync Power <br /> Part#: Description -- -- Si-1 Si-2 Si-3 Si-4 Total Oy <br /> PC2WL(15) Ceiling Horn W Strobe set at 15cd 0.0000 0.0710 N2 2 <br /> PC2WL(30) Ceiling Horn W Strobe set at 30cd 0.0000 0.0900 10 <br /> PC2WL(75) Ceiling Horn W Strobe set at 75cd 0.0000 0.1430 0 <br /> DB1 Explosion proof Horn.No Strobe.100dBA 0.0000 0.7000 E 1 E1 E1 3 <br /> XB4 Explosion proof Stobe,29CD,Cass 1 00000 0.3200 E 1 El El 3 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> a <br /> a <br /> a <br /> a � <br /> a � <br /> 0 <br /> 0 4� <br /> 0 <br /> 0 = <br /> o or, <br /> Typical Door Holders 0.0680 0.D000 0 <br /> If Devices per Circuit: 2 2 2 2 D 8 N <br /> Total Standby Circuit Calculated Amps(3): 0.000 0.000 0.000 0.D00 0,0000 0.0910 8- <br /> N <br /> Total Alann Circuit Calculated Amps(1): 1020 1.020 1020 0.142 00000 0.1450 1E <br /> Wire Gauge Used(awg): 14AWG 14AWG 14AWG 14AWG 14AWG Total <br /> Circuit Length(10: 60 100 120 0 0 Amps a a a a a Estimated Voltage Drop(dc): 0.32 0.53 0.64 0,00 0.00 Required <br /> Estimated EOL Voltage(dc): 2368 2347 2336 2400 2400 1202 <br /> Calculated Voltage Drop%F 1.3% 1 2.2% 1 2.7% 1 0.0% 1 0.0% PREPARED APL <br /> 1)Current Draw Measurement based on:UL1971,16-33V,DC,High db&Temporal Paten <br /> 2)Some Oui100f/WP Devices have the same Measured Current Draw as the Indoor Devices and may not listed separately above. REVIEW RM <br /> 3)When the APS is configured for'Doors',Oup)ut#4 shutsdown on loss ofAC Power.Therefore no"Standby'Current Drawis shown <br /> MMIDDIYY 12121/22 <br /> BATTERY LOAD CALC for API NAC P.S.Max Rating: 8.000 TOW Amps Required: 3.202 %used: 40 <br /> SCALE NOT TO SCALE <br /> Hours Standby: 24 Total Standby Current 0.0910 Total Hours Required for Standby(AH): 2.2 <br /> Minutes Alarm: 15 Total Alarm Cument 3 3470 Total Hours Required for Alarm(AH): Ott JOB NO. 501209854 <br /> Backup Generator? No Minimum Battery C¢e Needed(AH): 30 <br /> Voice Evacuation? No Spare Circuit Capacity 20% Spare Battery Capacity Required: 0 6 <br /> M ihtary? No Spare Battery Load Factor 20%.... Actual Battery Size Required(AH): 3 6 <br /> MAXIMUM CHARGER CAPACITY IS: 18AH Total AH Rated Batteries Supplied:= 7.0 <br /> SHEET FA-02 <br /> 0 2024 Everon.All rights reserved.The Producoservice names listed in this document are marks and or registered marks of their respective owners and used under license.Unauthorized use strictly prohibited. <br />