My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2331 ROCKEFELLER AVE 2025-10-06
>
Address Records
>
ROCKEFELLER AVE
>
2331
>
2331 ROCKEFELLER AVE 2025-10-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/6/2025 10:55:52 AM
Creation date
9/18/2025 11:06:16 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2331
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> 1/23/2024 1/23/2024 ELEC 06-ROUGH IN MIKE BEARDA CORRECTION eTRAKiT Inspection Request <br /> REQUIRED <br /> Notes: <br /> 1/22/2024 10:51 AM Tony Diwan <br /> 2331 Rockefeller Ave-Unit 08,Everett <br /> 2331 Rockefeller Ave-Unit 05,Everett <br /> 2331 Rockefeller Ave-Unit 11,Everett <br /> Contact Name:Tony Diwan <br /> Site Address:2331 ROCKEFELLER AVE <br /> Phone:2532009300 <br /> e-Mail:SUNNYDIWAN@GMAIL.COM <br /> MCB changed Inspection Type from ELEC 10-FINAL**to ELEC 06-ROUGH IN <br /> Panels in units are sub panels. 12"counter in kitchen requires an outlet <br /> 2/14/2024 2/14/2024 ELEC 10-FINAL** MICHAEL CORRECTION eTRAKiT Inspection Request <br /> WICKLANDER REQUIRED <br /> Notes: <br /> 2/9/2024 4:07 PM Tony Diwan <br /> 2331 Rockefeller Ave-Unit 12 <br /> 2331 Rockefeller Ave-Unit B <br /> 2331 Rockefeller Ave-Unit 03 <br /> 2331 Rockefeller Ave-Unit 02 <br /> 2331 Rockefeller Ave-Unit 10 <br /> 2331 Rockefeller Ave-Unit 06 <br /> 2331 Rockefeller Ave-Unit 07 <br /> 2331 Rockefeller Ave-Unit 09 <br /> 2331 Rockefeller Ave-Unit 08,Everett <br /> 2331 Rockefeller Ave-Unit 05,Everett <br /> 2331 Rockefeller Ave-Unit 11,Everett <br /> Contact Name:Tony Diwan <br /> Site Address:2331 ROCKEFELLER AVE <br /> Phone:2532009300 <br /> e-Mail:SUNNYDIWAN@GMAIL.COM <br /> /14/20244:27:27 PM(MICHAEL WICKLANDER) <br /> Properly insulate the butt splices in the old panel boxes and remove old panel guts if you are using them as junction boxes.Close all unused openings <br /> with properly rated breaker blanks etc. Ensure that all splices are free of shorts circuits,ground faults,etc.per NEC 110.7,as one blew up during <br /> inspection and there is evidence of several others blowing up on workers. <br /> The 2 small appliance circuits cannot have any other loads on them including the lights,dishwasher and hood,per NEC 210.52(C)(1)&(2). <br /> Dishwasher must have the NM_B cable sheathing installed all of the way into the junction boxes entering through a proper fitting. <br /> Insured proper support of all EMT and every unit.Also verify all set screws are properly set.All EMT connectors must be seated properly into the box <br /> and or panel. <br /> Ensure the ground wires terminate in the panel on the ground bus not pass through to the next box.All switch&receptacle boxes must be grounded <br /> with a grounding pigtail.All boxes must be closed for final.All ranges must be wired for 40 A minimum and also are required 4 wire receptacles and <br /> pigtails.Install a dedicated circuit for Dishwashers. Provide properly sized overcurrent protection for the baseboard heaters.Any and all unused wiring <br /> must be removed. Especially old range wiring.Properly label all circuits with legible panel schedules.Utilize proper fire,stop material in the corridors <br /> and between floors.Provide smoke/carbon monoxide detectors per code.provide range anti tip devices.Provide AFCI protection for all new devices <br /> etc.per NEC 210.12. <br /> This list may not be complete however these corrections were common to all units. <br /> I <br /> Printed:Thursday, 18 September,2025 5 of 8 rk <br /> SUPERION <br />
The URL can be used to link to this page
Your browser does not support the video tag.