Laserfiche WebLink
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> 2/14/2024 2/14/2024 ELEC 10-FINAL** MICHAEL CORRECTION eTRAKiT Inspection Request <br /> WICKLANDER REQUIRED <br /> Notes: <br /> 2/9/2024 4:09 PM Tony Diwan <br /> 2331 Rockefeller Ave-Unit 12 <br /> 2331 Rockefeller Ave-Unit B <br /> 2331 Rockefeller Ave-Unit 03 <br /> 2331 Rockefeller Ave-Unit 02 <br /> 2331 Rockefeller Ave-Unit 10 <br /> 2331 Rockefeller Ave-Unit 06 <br /> 2331 Rockefeller Ave-Unit 07 <br /> 2331 Rockefeller Ave-Unit 09 <br /> 2331 Rockefeller Ave-Unit 08,Everett <br /> 2331 Rockefeller Ave-Unit 05,Everett <br /> 2331 Rockefeller Ave-Unit 11,Everett <br /> Contact Name:Tony Diwan <br /> Site Address:2331 ROCKEFELLER AVE <br /> Phone:2532009300 <br /> e-Mail:SUNNYDIWAN@GMAIL.COM <br /> Properly insulate the butt splices in the old panel boxes and remove old panel guts if you are using them as junction boxes.Close all unused openings <br /> with properly rated breaker blanks etc. <br /> The 2 small appliance circuits cannot have any other loads on them including the lights,dishwasher and hood,per NEC 210.52©(1)&(2). <br /> Insured proper support of all EMT and every unit.Also verify all set screws are properly set..all EMT connectors must be seated properly into the box <br /> and or panel.Ensure the ground wires terminate in the panel on the ground bus not pass through to the next box.ill switch&receptacle boxes must be <br /> grounded with a grounding pigtail.All boxes must be closed for final.All ranges must be wired for 40 A minimum and also are required box and pigtail. <br /> dedicated circuit for just Dishwasher can be on a 15 or 20 dedicated circuit.The lighting must be on a separate circuit from small appliances.the heating <br /> needs to be properly sized overcurrent.that 30 is over rated for that size baseboard heater.Any and all unused wiring must be removed.Especially old <br /> range wiring.label all panels..and install printed legible panel schedules.Utilize proper fire,stop material in the corridors. <br /> 2/15/2024 2/15/2024 ELEC 10-FINAL** MIKE BEARDA NOT READY eTRAKiT Inspection Request <br /> Notes: <br /> 2/13/2024 2:20 PM Tony Diwan <br /> 2331 Rockefeller Ave-Unit 12 <br /> 2331 Rockefeller Ave-Unit B <br /> 2331 Rockefeller Ave-Unit 03 <br /> 2331 Rockefeller Ave-Unit 02 <br /> 2331 Rockefeller Ave-Unit 10 <br /> 2331 Rockefeller Ave-Unit 06 <br /> 2331 Rockefeller Ave-Unit 07 <br /> 2331 Rockefeller Ave-Unit 09 <br /> 2331 Rockefeller Ave-Unit 08,Everett <br /> 2331 Rockefeller Ave-Unit 05,Everett <br /> 2331 Rockefeller Ave-Unit 11,Everett <br /> Contact Name:Tony Diwan <br /> Site Address:2331 ROCKEFELLER AVE <br /> Phone:2532009300 <br /> e-Mail:SUNNYDIWAN@GMAIL.COM <br /> Corrections not complete <br /> Size range wire correctly,no sharp screws into panel. <br /> I <br /> Printed:Thursday, 18 September,2025 6 of 8 rk <br /> SUPERION <br />