Laserfiche WebLink
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> 11/21/2023 11/21/2023 PLUMB 03-ROUGH JASON CANCELLED eTRAKiT Inspection Request <br /> IN MORRISSEY <br /> Notes: <br /> 11/16/2023 12:32 PM Tony Diwan <br /> Contact Name:Tony Diwan <br /> Site Address:2331 ROCKEFELLER AVE LAUNDRY <br /> Phone:2532009300 <br /> e-Mail:SUNNYDIWAN@GMAIL.COM <br /> -Customer called to cancel. Inspection is rescheduled for 11/22/23. <br /> 11/22/2023 11/22/2023 PLUMB 08-FINAL** JASON CORRECTION eTRAKiT Inspection Request <br /> MORRISSEY REQUIRED <br /> Notes: <br /> 11/21/2023 6:51 AM Tony Diwan <br /> Contact Name:Tony Diwan <br /> Site Address:2331 ROCKEFELLER AVE LAUNDRY <br /> Phone:2532009300 <br /> e-Mail:SUNNYDIWAN@GMAIL.COM <br /> Previous Corrections Incomplete from 7/27/23. <br /> Upsize gas meter per PSE to accommodate for 398,000 BTU gas demand from tankless water heaters. Existing meter AC 250 limited to 300,000 BTU's. <br /> Support hard gas piping on exterior and interior of building to prevent stress on pipe with approved fasteners. <br /> Paint black iron pipe on exterior with corrosion resistant paint per the IFGC 404.11 Protection Against Corrosion <br /> Run 3/4"minimum hard gas pipe from 1"tee to each tankless unit with separate gas shut off valves and sediment traps for each unit per the IFGC <br /> table 402.2(1),409.5.1 Located Within Same Room,408.4 Sediment Trap. <br /> Run common venting per manufacturers installation instructions.Typically this requires a minimum of 3"for 2 units. <br /> 36"of termination clearance required for exhaust and intake on exterior per manufacturer and the IMC. <br /> Run condensate drain a minimum of 3/4"if combining both units per manufactures instructions.Slope minimum of1%per the IMC. <br /> Tanks must communicate internally via dipswitch settings per instructions when common vented. <br /> Support pex pipe above and next to tankless units with code approved fasteners per the UPC appendix I. <br /> Replace entire washing machine drain with 2"pipe and add vent per the UPC chap 7,8,9,and 10.Standpipe must be between 18"and 30"with trap in <br /> vertical alignment. <br /> *** Have manufacturers installation instructions for tankless water heaters onsite for review during next inspection. <br /> *** List is not exhaustive.Ok to have plumber call for questions or clarification. <br /> CORRECTION JASON <br /> 12/4/2023 T12/4/2023 PLUMB 08 FINAL** MORRISSEY EY REQUIRED eTRAKiT Inspection Request <br /> Notes: <br /> 12/1/2023 7:31 AM Tony Diwan <br /> Contact Name:Tony Diwan <br /> Site Address:2331 ROCKEFELLER AVE LAUNDRY <br /> Phone:2532009300 <br /> e-Mail:SUNNYDIWAN@GMAIL.COM <br /> -Discussed options for bringing water heating system into compliance with code. <br /> *** Recommend hiring licensed plumbing contractor that can run proper calculations to ensure adequate hot water to all apartment units and ensure <br /> hot water heating system is installed to code. <br /> ***-(If single tankless unit is used),Support hard gas piping on exterior and interior of building to prevent stress on pipe with approved fasteners. <br /> Paint black iron pipe on exterior with corrosion resistant paint per the IFGC 404.11 Protection Against Corrosion <br /> Run 3/4"minimum hard gas pipe from 1"tee to tankless unit with separate gas shut off valve and sediment trap per the IFGC table 402.2(1),409.5.1 <br /> Located Within Same Room,408.4 Sediment Trap. <br /> -36"of termination clearance required for exhaust and intake on exterior per manufacturer and the IMC. <br /> I <br /> Printed:Tuesday,02 January,2024 2 of 3 rk <br /> SUPERION <br />