2015 Washington State E. I Code Compliance Forms for Commercial,R2 and R3 over ories.and all R1-Page 8 of 17 <br /> 'Mechanical Permit Plans Checklist MECH-CHKI <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: Everett Community College-Learning Resource Center Date 7/24/2020 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable TLocation in Building Department <br /> (yes,no,na) Code Section Code Provision Information Required-Mustbe in permit documents Documents Notes <br /> C402.4.1.4 Increased prescriptive <br /> Yes C403.6 maximum vertical Indicate that all occupied,conditioned spaces are served by a DOAS per C403.6 <br /> fenestmbon area with DOAS <br /> M3 Series <br /> Additional Efficiency Package Option,Dedicated Outside Air Systems(DOAS) <br /> Yes C406.6 Building provided wth To comply with additional efficiency package option,indicate that 901%or more of all occupied, <br /> DOAS conditioned s aces are served by a DOAS per 0403.6 M3 Series <br /> Multiple Zone Air Systems <br /> Air systems serving multiple Identify supply air systems serving multiple zones and the zones they serve on plans;indicate <br /> Yes C403.4.4 zones whether system is VAV and method of primary air control;or provide supporting <br /> documentation for applied exception to VAV M3 Series <br /> Provide equipment schedules on plans or MECH-EQ form that list all VAV air terminals and MO Series, <br /> types M3 Series <br /> VAV systems serving For each air terminal include:maximum airflow rates for primary supply air during zone peak <br /> Yes C403.4.4 multiple zones heating and zone peak cooling;maximum airflow during reheating,retooling or mixing; <br /> minimum airflow rate to maintain required ventilation,and the basis for these values;it IMC or <br /> ASHRAE 62.1 multiple zone equation is basis for minimum flow rates,provide calculation on MO Series, <br /> plans M3 Series <br /> Yes C403.4.4.1 Single duct VAV terminal Indicate single duct terminal units are configured to reduce primary supply air before reheating <br /> units or retooling Ml0 Series <br /> NA C403.4.4.2 Dual duct systems-terminal For systems with separate warm air and cool air ducts,indicate terminal units are configured to <br /> units reduce the flow from one dud to minimum before mixing with airfrom the other dud NA <br /> Indicate locations of dud static pressure sensors on plans;include at least one sensor per <br /> major dud branch;verify controller setpoint pressure at each sensor is<1.2 inch w.g. M10 Series <br /> C403.A.1_1 VAV system static <br /> Yes pressure sensors- For systems with zone level DDC,indicate controls are configured to monitor zone damper <br /> C403.4.1.2 sensors and DDC set points positions and reset static pressure setpoint based on the zone requiring most pressure; <br /> include control logic that automatically detects and generates an alarm if any zone excessively <br /> drives reset logic,and allows building operators to exclude zones from reset logic <br /> M10 Series <br /> Multiple-zone VAV system For systems with zone level DDC controls,indicate controls are configured to automatically <br /> Yes C403,4.4.3 ventilation optimization reduce outdoor airflow in response to changes in system ventilation efficiency;or exception <br /> controls taken M10 Series <br /> Yes C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or <br /> outdoor air temperature;orexception taken M10Series <br /> Multiple Zone HVAC Systems,High Efficiency VAV-Required for systems utilizing C41)3.6 DOAS Exception 2,must comply with all 16 provisions <br /> C403.7, Indicate system is configured for 100%air economizer operation and complies with all related <br /> NA Item 1 Air economizer economizer requirements per C403.3(without economizer exceptions) NA <br /> C403.7, Provide DDC controls for all components of system;identify all DDC system input/output <br /> NA Item 2 Direct digital controls(DDC) control points;indicate capability for trending and graphical display NA <br /> For systems with minimum OSA>2,500 dm,indicate outdoor airflow monitoring station that <br /> NA C403.7, Outdoor airflow measures OSA intake under all load conditions;indicate control sequence that increases or <br /> Item 3 measurement and reduction reduces system OSA rim based on VAV terminal feedback of ventilation efficiency(per <br /> C403.4.4.3 without exceptions)or DCV(per C403.2.6.2) NA <br /> C403.7, For systems with minimum OSA>2,500 cfm,indicate supply airflow monitoring station <br /> NA Item 4 Supply airflow measurement capable of measuring supply air delivered to VAV terminals under all load conditions NA <br /> C403.7, Zone isolation and Verify maximum area served by a single HEVAV system is<_50,000 sf,or one entire floor, <br /> NA Item 5 maximum area served whichever is greater,in addition if a system serves>25,000 sf,that includes areas that are <br /> expected to be occupied non-simultaneously,indicate zone isolation controls per C403.2.4.4 <br /> NA <br /> C403.71 Interior/exterior zone Verify that VAV terminals serving interior cooling driven loads are sized per design supply air <br /> NA Item 6 design supply air temperature that is 5°F higher than VAV terminals serving exterior zones it <br /> temperature NA <br /> C403.7, Maximum air terminal inlet Identify air terminals with minimum primary airflow setpoints>50%of maximum setpoint in <br /> NA Item 7 velocity equipment schedule or MECH-EQ form;indicate airterminal inlet velocity does not exceed 900 <br /> fpm NA <br /> C403.7, Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC <br /> NA Item 8 Sequence of operation 36 NA <br /> NA C403.7, Maximum aliowable system Verify fan system bhp is_<90%of the bhp limit per Option 2 equation in Table C403.2.11.1(1), <br /> Item 9 brake horsepower provide MECH-FANSYS forth for each system NA <br /> Indicate all series and parallel terminal fans have electronically commutated motors;indicate <br /> NA C403.71 Fan-powered terminal unit DDC control system is configured to vary air terminal fan speed as a function of the load; <br /> Item 10 motor and controt indicate fan speed during periods of low heating,low cooling,or ventilation only is<_66%of <br /> peak design air flow or provide supporting documentation for applied exception NA <br />