Laserfiche WebLink
REPLACE EX 12"X6" REDUCER. 12" 4 4' MIN COVER TO TOP OF <br /> CONNECTION TO EX 12" MAIN BY C5.20 C5.10 PIPE TYR FOR ALL PIPE <br /> CITY WITH 12"X11.25' HORIZ BEND. BETWEEN 4+00 AND 10+00 <br /> 30 <br /> 20 IFEX 6" W TO BE <br /> RECONNECTED I OJ <br /> EX 24" SSFM, <br /> IE=9.5f <br /> 3' MIN COVER w <br /> Z -----_ RECONN - 1 EX GRADE-, EX 8" D, IE=1 CE N <br /> �PROTEC -IN-PLACE <br /> EX 8" SD, IE=10.7t <br /> F PROTECT-IN-PLACE 1 w <br /> < - - z_ <br /> W J <br /> W 10 <br /> EX E 14.5 D Q IE=11.6't < <br /> RECONN EX JFH EX 24" SS, _ 12"X30 12" MIN CLEAR 12" MIN CLEAR <br /> ASSEMBLY IE=6.8 IE-8.2 f HORIZ BEND IE=8.2 f IE=7.6' <br /> STA 4 64.01 <br /> 0 <br /> W1 4+00 Wi 5+00 Wi 6+00 W1 7+00 <br /> ALIGNMENT W1 - WATER PROFILE <br /> C5.1 C5.3o MIN TRANSITION <br /> WITHIN <br /> I C5.20 C5.30 NORTON TERMINAL I <br /> I I <br /> 1 3/4" METERED WS 1 <br /> FOR GUARD SHACK O <br /> p EX 3/4" WS TO I J <br /> m BE RECONNECTED w <br /> < 1 FINISHED GRADE m <br /> w EX 3 4 WE TO EX GRADE EX 2" WS, EX 6" SSS, IE=9.7t 3' MIN COVER __„ 4' MIN COVER RECONN EX 2" EX GRADE W <br /> BE RECONNECTED PROTECT-IN-PLACE WS AT STA 9+57 1wjl <br /> 1 RECONN AT 1 <br /> STA 9+57 <br /> zl 12" GV RECONN EX 1" WS Iz <br /> J J <br /> U UTILITY TRENCH U <br /> IE=9.5'f IE 9.9'f IE=9.5't CUT-OFF WALL. SEE IE=9.6'f <br /> Q 1 RELOCATE AND < <br /> �I RECONN EX 3/4" WS, RECONN EX FH IE=7. 't EX 24" SSFM, IE= .5t RECONN EX FH DETAIL 3, SHT C4.14 3" SSFM IN CDF I� <br /> STA 7+27.40 RECONN EX 3/4" S IE=7.6'f 18" MIN CLEAR PROTECT-IN-PLACE ENCASEMENT, <br /> AT STA 8+5.50 <br /> PROPERTY LINE IE=9.0t 1 <br /> IWl 8t00 W1 9t00 W1 1Ot00 I <br /> ON <br /> 1 ALIGNMENT W1 - WATER PROFILE (CONTINUED) <br /> AVENUE <br /> FEDERAL IN <br /> C L AVENUE TERMINAL <br /> C5.1 C5.30 <br /> I I^_ <br /> M <br /> j 1 AIR-VAC 1 I U <br /> PER COE STD PLAN 512 <br /> CO <br /> < FIN) HED GRADE COMM AND POWER STA 12+17 ~ <br /> w <br /> w FLANGED DUCTBANK, SEE ELEC 3' MIN COVER, TYR 2 <br /> w n <br /> EX GRADE 15" SD PIPE, <br /> N1 12" GV E=10.8t Iw <br /> w - n <br /> z 1 <br /> J W <br /> 2 z <br /> E- IE=11.8't777 EX SD, TO BE IE=11.6't U <br /> DEMOLISHED 12"X12"X6" TEE FOR FH 1C" MIN CLEAR 42" CITY M, 12'" MIN CLEAR ASSEMBLY PER COE STD 507 I< <br /> 18" SD PIPE, BY CITY, ICP IE=8.3't <br /> IE=7.54t STA 12+26, LT-24' <br /> W1 11+00 Wi 12+00 WI 13+00 <br /> GENERAL NOTES <br /> 1. EXISTING FOUNDATION STRUCTURES SHOWN IN PROFILE ARE APPROXIMATE AND SHOWN FOR REFERENCE ONLY. NOT 1 ALIGNMENT W1 - WATER PROFILE (CONTINUED) IF CALL 48 HOURS <br /> ALL FOUNDATION STRUCTURES/DEBRIS ARE SHOWN.CONTRACTOR SHALL CONFIRM EXISTING CONDITIONS PRIOR TO C5.1 C5.30 BEFORE YOU DIG <br /> START OF WORK. IF CONDITIONS DIFFER FROM THOSE SHOWN IN PROFILE,THE CONTRACTOR SHALL NOTIFY THE <br /> ENGINEER AND NOT BEGIN CONSTRUCTION UNTIL CHANGED CONDITIONS HAVE BEEN EVALUATED. <br /> 2. EXISTING UTILITY LOCATIONS AND DEPTHS ARE SHOWN APPROXIMATE.CONTRACTOR SHALL POTHOLE PRIOR TO ` City of Everett DIAL 811 <br /> m START OF WORK. PROTECT-IN-PLACE ALL EXISTING UTILITIES SHOWN IN PROFILE,UNLESS NOTED OTHERWISE. EVERETT Reviewed for Permit 10/26/2021 <br /> om r� VERT DATUM: NAVD 88 <br /> 3. THE WATER MAIN DESIGN ASSUMES THAT THE EXISTING WATERMAIN WAS CONSTRUCTED WITH <br /> 5-FEET OF COVER. THE CONTRACTOR SHALL POTHOLE TO CONFIRM THE EXISTING LOCATION 10' 0 10' 20' CONY TO MLLW = NAVD88+2.03 <br /> C) AND DEPTH AT BOTH ENDS PRIOR TO ORDER OF MATERIALS AND START OF WORK, HORZ DATUM: NAD 83/91 <br /> INCLUDING THE CITY WORK TO CONNECT TO THE EXISTING MAIN. IF CONDITIONS DIFFER <br /> ry'p1 FROM THOSE SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND 5' 15' W <br /> I'll NOT BEGIN CONSTRUCTION UNTIL THE CHANGED CONDITIONS HAVE BEEN EVALUATED. SCALE: 1"=10' \\ <br /> C< <br /> N <br /> 0 LU <br /> N PROJECT ENGINEER: SCALE: <br /> PORT OF EVERETT °W NO, <br /> r A� A. p9 C5.30 <br /> ' Port Of _ ES WATSON 1" - 10' <br /> ���pt tAyg��T� DESIGNED BY: DATE: <br /> e 09/27/202, NW REVISED PER RFIDID & WHSE e��s` y� J. BECKER 06/21/2021 NORTON TERMINAL DEVELOPMENT GIP NO. <br /> EVERETT1cpff GVL YARD DRAINAGE DRAWN BY CHECKED BY & MTCA 3RD INTERIM ACTION -8-goo-os V <br /> 10/15/2021 NW REVISED PER CITY �` K. EDWARDS, D. YU N. WATSON PROJECT <br /> N 1601 Sth Avenue,Suite 1300 PRE-CONSTRUCTION MEETING <br /> N P,0. BOX 538 Seattle,Washington 98101 Q�, � a WATER PROFILES NO. MT-NT-2021-02.2 <br /> ® 06/21/2021 NW ISSUED FOR BID �syYx�q�,G" APPROVED BY <br /> N Q : <br /> EVERETT, WA 98206 (206)382-0600 Fax b 0 <br /> (425) 259-3164 PROJECT NO.1600120 NO. DATE BY REVISION NO. DATE BY REVISION (SHEET 1 OF 7) SHEET NO. 81 OF 150 LL <br />