ELECTRICAL FOR New buildout of Compass Health building
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHEET NOTES: FLAG NOTES& <br /> A. ALL RECEPTACLES IN AREAS ACCESSIBLE TO CLIENTS AND/OR THE 1. INDOOR UNIT TO BE FED FROM THE OUTDOOR UNIT.PROVIDE 7. PROVIDE POWER CONNECTIONS FOR DOC SYSTEM POWER SUPPLIES. ¢Yo h <br /> NUMBERING FOR ALL FSDS HAS BEEN REVISED. PUBLIC ARE TO BE UL LISTED TAMPER RESISTANT AS PER THE DISCONNECTS AT BOTH LOCATIONS AND CONNECT PER CODE AND FIELD VERIFY EXACT LOCATIONS AND REQUIREMENTS WITH MECHANICAL <br /> CONSIDER ALL FSD TAGS TO BE BUBBLED. REQUIREMENTS OF NEC 406.12(5). MANUFACTURER'S INSTRUCTIONS.GROUND PER CODE AND CONTRACTOR. �'`• s <br /> MANUFACTURER'S INSTRUCTIONS.FIELD VERIFY EXACT CONNECTION <br /> B. SEE POWER PLANS FOR RECEPTACLES FOR GENERAL PURPOSE, REQUIREMENTS FOR FINAL UNIT SELECTED FOR PROJECT WITH 8. CONNECT COMPLETE 120V GAS METER PROVIDED BY OTHERS PER CODE <br /> APPLIANCES,ETC. MECHANICAL CONTRACTOR;ADVISE ENGINEER OF CONFLICTS. AND MANUFACTURER'S INSTRUCTIONS.FIELD VERIFY CONNECTION mrs� <br /> REQUIREMENTS AND LOCATIONS. <br /> C. AREAS ABOVE CEILINGS IN PROJECT ARE BEING USED AS RETURN AIR 2. ALL HP-UNITS AND BC-UNITS ARE PROVIDED BY OTHERS WITH 2O8V1 1PH <br /> PLENUMS.CONTRACTOR TO USE PLENUM RATED CABLE/INSTALLATION CONDENSATE PUMP.ELECTRICAL CONTRACTOR TO CONNECT PUMP TO A <br /> TO MEET CODE REQUIREMENTS. SAME CIRCUIT AS MECHANICAL UNIT AND PROVIDE DISCONNECTS PER BEL3 <br /> CODE REQUIREMENTS.FIELD VERIFY CONNECTION LOCATIONS AND <br /> REQUIREMENTS WITH MECHANICAL CONTRACTOR.TYPICAL FOR ALL HP- <br /> AND BC-UNITS. Alt T <br /> 3. PROVIDE POWER CONNECTIONS FOR VRF SYSTEM CONTROL PANELS AND Ankrom <br /> THE DDC SYSTEM CONTROL PANEL.FIELD VERIFY EXACT LOCATIONS AND <br /> REQUIREMENTS. <br /> 35 NORTHWEST DAMS,SUITE 300 <br /> PORTLAND,OR 97208 <br /> 4. ALL FSDS ARE TO BE CONNECTED TO THE 702 OPTIONAL STANDBY 503.245.7100 <br /> SYSTEM.CONNECT ALL FSDS ON LEVEL 4 TO CIRCUIT OL3M-14.FIELD <br /> VERIFY EXACT LOCATIONS AND CONNECTION REQUIREMENTS,CONNECT 1505 STH AVE,SUITE 300 <br /> COMPLETE PER CODE REQUIREMENTS.TYPICAL FOR ALL FSDS ON LEVEL. SEATTLE,WA 98101 <br /> 205.575.1500 <br /> 5. LAV PROVIDED WITH TRANSFORMER FOR SENSORED FAUCET BY 1014 HOWARD STREET <br /> PLUMBING CONTRACTOR.ELECTRICAL CONTRACTOR TO PROVIDE SAN FRANCISCO,CA 94103 <br /> RECEPTACLE BEHIND LAV SHROUD ON GFCI PROTECTED CIRCUIT FOR 415.252.7083 <br /> TRANSFORMER;FIELD VERIFY EXACT LOCATION.CONFIRM EXACT 0ANKROM MOISAN ARCHITECTS,INC. <br /> REQUIREMENTS WITH PLUMBING CONTRACTOR. <br /> SIDER+BYERS ASSOCIATES,INC. <br /> 6. SINK PROVIDED WITH TRANSFORMER FOR SENSORED FAUCET BY r(A\\ <br /> PLUMBING CONTRACTOR.ELECTRICAL CONTRACTOR TO PROVIDE MECHANICAL AND ELECTRICAL`�/ <br /> RECEPTACLE ON GFCI PROTECTED CIRCUIT FOR TRANSFORMER;FIELD 192 NICKERSON,SUITE 300 <br /> VERIFY EXACT LOCATION.CONFIRM EXACT REQUIREMENTS WITH SE WA 88109 <br /> PLUMBING CONTRACTOR. zoe.285,2zas.2955 <br /> 7 8 9 10 11 12 13 14 15 CPTHM-llteefPIASS <br /> alth <br /> LOTUS <br /> - _ development partners <br /> ---_ _- - - F --=__ ----- - - - ---__ - - - - - - - - ----0 <br /> HP <br /> r--_ HP467 HP-061 <br /> L3H-2,4,-- L3H-2, L3H•2,4 7 OL3M-24 <br /> I I I ` DL.PM-2 <br /> M-24 L3H-2,4 <br /> , i I <br /> 71 <br /> HP-081 DDCC 702 <br /> ®L3H-2,4 I �2 Q 70Z TE•500 OL3M-2 <br /> -_- OL3M•4 <br /> i' L214-0 HP-451 <br /> RCP-7 702 OL4H-8 <br /> I <br /> L3H-5,7 ® P-C405 FSD 4.40 7D20 <br /> -0.3 L H-24 '- <br /> RCP-8 ® 702 LAV-1 O Rim <br /> L3H-5,7 OL3M-12 d 7 <br /> AGEMR 1 -`/'� ©702 I <br /> F 0-0.2 FSD-0.1 OL3M-2® Q <br /> 702 HP-050 ' <br /> _ OL4E•18,20 / \ ---- CO C7 OL4H-5 2® U <br /> - - LI LAV- 5 I1 BC-12 FSD-438 I HP-456 O LU <br /> ---- --_---_ ---_ _ _ _ Of <br /> FSD-0_41 FSD-4.4 _ _ _ - OL3M-12_ _ _OL4H•8 TYPICAL _ _ OL4H-8 +; m j <br /> FSD-0.29 D LU <br /> I I I r l �_ _� <br /> } - - - -{- - - - - - - - S-0.28 <br /> Lu <br /> 4 TYPICAL FOR <br /> ALL FSDS ON __ Q <br /> THIS LEVEL O m a <br /> N <br /> O <br /> 12Y PREFINISHEO ALUMINUM M <br /> OL3M•8 LAV-1 <br /> FSD-4.6 OL3M-8 _ <br /> REVISION DATE REASON FOR ISSUE <br /> I FSD-4.8 FSD-4.7 LAV-1 Q I LAVA Q HP-030 LAV-1 O 1 -2 0906.22 OL3M-B <br /> - - _ OL3M-8 - - - - - - - - - - - - QL4H-6 OL3M-1O - - 3 2022 ENDUM 10 AS[-Dl _5 <br /> 4 10.20.22 A51-01 <br /> - 5 1D.27.23 ASI-04 <br /> i, <br /> - <br /> �02-J <br /> --- J `-----J --- --J - - _TT <br /> yY <br /> FP <br /> CAL <br /> 702 702 , BDCI APPROVAL STAMP <br /> - <br /> FSD-0.9 `=- 70 702-- 702 2 FSD-0.37 <br /> 702® HP 2 702® P 16 70 HP-4 OL4H-7 <br /> OL4H- SD-0.14 4H-7 FSD- OL4H- FS F D-0.33 FSD 36 <br /> ® I I I I F D-0.30 I I I I <br /> ® FSD-0.31 o FSD-4. FSD4.35 1 <br /> .•,c.,o.. _ 702 OL H•8 5 J OL FSD-0.32 27 <br /> 702® <br /> - _- 4HA r, I �- 4XJ 702 1 702® HP-429 I I <br /> - 702 m � LEVEL 4 FLOOR <br /> - O� OL4H-8 <br /> - _ _.OL3M-24 HP 28 <br /> FSD4.10 _ -- - -- OL4 --- - OL H-8 PLAN- <br /> FSD.4.1 -- _ _ _ __ - -- _ _ _ - �-/ MECHANICAL <br /> FSD-0.12 FSD-0.15 FSD4.17 FSD .20 FS .23 FSD-426 <br /> FSD4.18 FSDF4.21 3M210 5 S.6 6 L3M-10 6 ASI-04 SET <br /> FSD-0.13 FSD-0.i6 FS 22 FSD-0.25 A S <br /> DATE PROJECT NUMBER <br /> LEVEL 4 FLOOR PLAN - MECHANICAL CONNECTIONS PLAN D ® �o.zMBER 21016 <br /> IN SCALE: PLAN <br /> SCALE:1/5'=1'-0- SHEET NUMBER <br /> 0.202 <br /> E .04M <br /> 0 4 8 18 32 <br />