Plumbing Permit - Compass Health
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
$g <br /> 50�°F rgd.,p <br /> PLUMBING SYMBOLS LEGEND PLUMBING NOTES ABBREVIATIONS <br /> 7108 <br /> 1. PLUMBING FIXTURES SHALL BE DESIGNED OR EQUIPPED TO MEET &?7�0°1� <br /> LINETYPE LEGEND PIPE VALVES AND SPECIALTIES FOLLOWING MAXIMUM WATER USE EFFICIENCY STANDARDS: ACT ACOUSTICAL CEILING TILE MBH 1000 BRITISH THERMAL UNITS PER HOUR s7oNA11 <br /> A WATER CLOSETS TANK STYLE OR FLUSH VALVE 1.28 GPF ADA AMERICANS WITH DISABILITIES ACT MED MEDIUM <br /> EXISTING ( ) ADJ ADJUSTABLE MEP MECHANICAL,ELECTRICAL,PLUMBING <br /> NEW WORK DARK/HEAVY P-1 PLUMBING EQUIPMENT B. SHOWER HEADS 1.75 GPM <br /> AFF ABOVE FINISHED FLOOR MEZZ MEZZANINE <br /> C. PUBLIC LAVATORY FAUCETS. 0.5 GPM AFG ABOVE FINISHED GRADE MIN MINIMUM <br /> PIPING SYSTEM LABELS X MEDICAL TAG D. SINK FAUCETS 1.75 GPM ALT ALTERNATE MISC MISCELLANEOUS <br /> SINK AND LAVATORY DRAINS SHALL BE CHROME PLATED 17 GA.BRASS AP ACCESS PANEL IRIV <br /> ---CW--- COLD WATER TUBING BY ENGINEERED BRASS, DEARBORN BRASS OR BRASSCRAFT. APPROX APPROXIMATE N/A NOT APPLICABLE <br /> ----HW---- HOT WATER PROVIDE INSULATED P-TRAP AND SUPPLY COVERS(TRUEBRO OR EQUAL) ARCH ARCHITECTURAUARCHITECT NC NORMALLY CLOSED A <br /> DETAIL NUMBER AT ALL EXPOSED P-TRAPS AND SUPPLIES PER A.D.A.STANDARDS, AS AIR SEPARATOR NEG NEGATIVE <br /> -(140)---- HOT WATER(TEMPERATURE) M-1 SHEET 2. PLUMBING FIXTURE MOUNTING SHALL COMPLY WITH CONTRACT AUX AUXILIARY NIC NOT IN CONTRACT <br /> HWC- HOT WATER CIRCULATING O DOCUMENTS,ADA,AND WASHINGTON STATE ACCESSIBILITY CODE. NOM NOMINAL 38 NORTHWEST DAVIS,SUITE 300 <br /> FLAG NOTE BEE BELOW FINISHED FLOOR NPC NON-POTABLE COLD WATER PORTLAND,OR 97209 <br /> SD STORM DRAIN 3. INSTALL WATER HAMMER ARRESTORS ON HOT&COLD WATER PIPING BEG BELOW FINISHED GRADE NPCW NON POTABLE COLD WATER 503.245.7100 <br /> pW PUMPED WASTE OF EACH FIXTURE GROUP AND AT ALL FIXTURES W/QUICK ACTING VALVES. BHP BRAKE HORSE POWER NPH NON-POTABLE HOT WATER <br /> Al REVISION TAG UNITS SHALL BE ZURN"SHOKTROLL"OR EQUAL. SELECT UNIT SIZE 1505 TL ,WA'SUITE 300 <br /> -��- WASTE(BURIED) AND LOCATION PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORD SOP BUILDING NPHR NON-POTABLE HOT WATER RETURN SE.576.1 00 98101 <br /> BOP BOTTOM OF PIPE NPT NATIONAL PIPE THREAD zos.57s.1soo <br /> W WASTE(ABOVE GRADE) WITH PDI STANDARD WH-201. PROVIDE ACCESS PANELS AT ARRESTORS BTU BRITISH THERMAL UNIT NTS NOT TO SCALE <br /> r7% PLUMBING RISER NO. ABOVE GWB CEILINGS. ALL ACCESS PANELS AND DOORS SHALL BE BTUH BRITISH THERMAL UNIT PER HOUR 1014 HOWARD STREET <br /> -GW- GREASE WASTE P 1 SAN FRANCISCO,CA 94103 <br /> SHEET ELMDOR FAB.STEEL SLK SERIES OR EQUAL WITH 14 GAUGE DOOR AND OD OUTSIDE DIAMTER/OVERLOW DRAIN 415.252.7063 <br /> --- V--- VENT FRAME. PROVIDE WITH CYLINDER LOCK,CONTINUOUS PIANO HINGE CA COMBUSTION AIR OFCI OWNER FURNISHED CONTRACTOR INSTALLED CANKROM MOISAN ARCHITECTS,INC. <br /> -RL RAINLEADER AND PRIME COATED READY FOR PAINTING. CLG CEILING OFOI OWNER FURNISHED OWNER INSTALLED <br /> 1 SECTION NUMBER 4. COLD WATER AND HOT WATER PIPING SHALL BE INSULATED AND ROUTED CMU CONCRETE MASONRY UNIT ORD OVERFLOW ROOF DRAIN SIDER+BYERS ASSOCIATES,INC. <br /> -OD OVERFLOW DRAIN SHEET NUMBER CO CLEANOUT ORL OVERFLOW RAINWATER LEADER MECHANICALAND rd <br /> FULL SIZE WITH APPROPRIATE SIZE REDUCTION AT POINT COND CONDENSATE ELECTRICAL <br /> ---NPW--- NON-POTABLE COLD WATER OF CONNECTION TO FIXTURE. 1/2"WATER LINE LIMITED TO W-O" 192 NICKERSON,SUITE 300 <br /> CW COLD WATER 4P PRESSURE DIFFERENTIAL SEATTLE,WA 98109 <br /> -G OR P- NATURAL GAS OR PROPANE DISTANCE FROM FIXTURE. "DEAD-LEGS"OR"FUTURE"STUBS ON ACTIVE CX CONNECT TO EXISTING <br /> PD PLANTER DRAIN;PRESSURE DROP <br /> POTABLE WATER LINES SHALL BE LIMITED TO 4"TO PREVENT STAGNANT 206.285.2966 <br /> F FIRE SERVICE PIPE VALVES AND SPECIALTIES WATER CONDITIONS. dB DECIBEL PERF PERFORATED <br /> DIRECTION OF FLOW 5. INSTALL WATER PIPING ON WARM SIDE OF BUILDING INSULATION. SEE DCVA DOUBLE CHECK VALVE ASSEMBLY PH PHASE <br /> CA COMPRESSED AIR GATE VALVE SPEC.FOR INSULATION SYSTEMS. SEE DWGS.FOR ELEC.HEAT TRACE DDCV DOUBLE DETECTOR CHECK VALVE PIV POST INDICATOR VALVE <br /> _D81- GLOBE VALVE REQUIREMENTS, SEE PLUMBING DETAILS FOR PIPE HANGER STYLE. DDCVA DOUBLE DETECTOR CHECK VAVLE ASSEMBLY PLBG PLUMBING <br /> DI DIONIZED WATER p� NON RISING STEM VALVE SEE SPEC.FOR HANGER SPACING. DF DRINKING FOUNTAIN PRESS PRESSURE C MPASS <br /> V VACUUM t 6. WHEN CONNECTING TO EXISTING BURIED WASTE PIPING VERIFY PROPER DFU DRAINAGE FIXTURE UNIT PRV PRESSURE REDUCING VALVE <br /> -w RISING STEM GATE VALVE FLOW CONDITIONS BEFORE COVERING. BURIED WASTE&VENT PIPING DHW DOMESTIC HOT WATER PSF POUNDS PER SQUARE FOOT ,,1 <br /> C CONDENSATE BALANCING VALVE(CIRCUIT SETTER) SHALL BE MIN.2"DIA&SLOPED 1/4"/FT.,UNLESS OTHERWISE NOTED. DHWC DOMESTIC HOT WATER RECIRCULATION PSI POUNDS PER SQUARE INCH Health <br /> -PC PUMPED CONDENSATE AUTOFLOW VALVE PVC OR ABS PIPING SHALL BE USED ONLY IF APPROVED BY 0 OR DIA DIAMETER PSIG POUNDS PER INCH GAUGE <br /> DN DOWN <br /> X„ ADMINISTRATIVE AUTHORITY,SEE SPECIFICATIONS FOR FURTHER INFO. DWG(S) DRAWING(S) QTY QUANTITY <br /> SLOPE SYMBOL CHECK VALVE 7. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS EXCEPT IN SHOWER DWV DRAIN,WASTE,VENT <br /> (X'PER FOOT) �, LET U S <br /> �vr BALL VALVE STALLS OR OTHERWISE NOTED ON DWGS. CONTRACTOR SHALL INSTALL RD ROOF DRAIN <br /> ACCESS PANELS WHERE PRIMERS ARE CONCEALED IN WALLS. EA EACH READ REQUIRED <br /> PIPE FITTINGS PRESSURE REDUCING VALVE 8. COORDINATE VENT THROUGH ROOF(VTR)LOCATIONS WITH HVAC UNITS. EEW EMERGENCY EYEWASH RL RAIN WATER LEADER <br /> 9 PIPE DOWN MAINTAIN MIN.10'-0"CLEARANCE. OFFSET VTR AS NECESSARY. EFF EFFICIENCY RM ROOM development partners <br /> SOLENOID VALVE COORDINATE PIPE ROUTING WITH HVAC AND SPRINKLER CONTRACTORS. ELEV ELEVATION RPBP REDUCED PRESSURE BACKFLOW PREVENTER <br /> 0 PIPE UP 9. SITE WATER PRESSURE IS 87 PSI PER CITY OF EVERETT. EQUIP EQUIPMENT RPM REVOLUTIONS PER MINUTE <br /> PRESSURE GAUGE 10.RISER DIAGRAMS&PLANS DO NOT SHOW SOME PIPING OFFSETS REQUIRED ES EMERGENCY SHOWER RLX RELOCATE EXISTING <br /> -0- TEE UP ET EXPANSION TANK RV RELIEF VALVE <br /> FOR STRUCTURAL CLEARANCES. EXACT ROUTING MAY VARY FROM THAT EX EXISTING/EXISTING TO REMAIN RX REMOVE EXISTING <br /> TEE DOWN THERMOMETER INDICATED.ALL WASTE PIPING INCLUDING RISERS ON RESIDENTIAL EXP EXPANSION <br /> -�I�- UNION 1`74 STRAINER LEVELS TO BE CAST IRON. S SINK <br /> 11.PROVIDE ELECTRIC HEAT TRACE UNDER PIPING INSULATION FOR ALL WATER FC FAIL CLOSED S STORM <br /> X PIPE ANCHOR POINT SAFETY VALVE PIPING INSTALLED IN UNHEATED GARAGE SPACES. FCO FLOOR CLEANOUT SCFM STANDARD CUBIC FEET PER MINUT <br /> " 12.CONFIGURE PIPING FOR SUDS RELIEF AS REQUIRED BY THE UPC. FD FLOOR DRAIN SD STORM DRAIN <br /> PIPE GUIDE 13.ALL LEVER CONTROLLED WATER CLOSETS TO BE INSTALLED WITH FDC FIRE DEPARTMENT CONNECTION SF SQUARE FOOT <br /> FLANGE PIPING FLEXIBLE CONNECTIONS THE LEVER ON THE OPEN SIDE OF THE BATHROOM. FF FINISHED FLOOR SFU SUPPLY FIXTURE UNIT <br /> FLA FULL LOAD AMPS SH SHOWER <br /> CAP \� BUTTERFLY VALVE FM FORCE MAIN S.O.V. SHUTOFF VALVE <br /> FO FAIL OPEN SPEC SPECIFICATION <br /> ----I I OR 1 CAP FP FIRE PROTECTION S/S,OR SS STAINLESS STEEL <br /> FPM FEET PER MINUTE STD STANDARD <br /> DRAINS AND CLEANOUTS HOSE BIBB FPS FEET PER SECOND SYM SYMBOL <br /> ENERGY CODE NOTES FS FLOORNK <br /> ® FLOOR SINK �� DOUBLE CHECK VALVE FSZV FIREIRESPRINKLER ZONE VALVE ASSEMBLY T&P TEMPERATURE AND PRESSURE RELIEF VALVE <br /> 1. SEE SCHEDULE FOR WATER HEATER EQUIPMENT TYPE,CAPACITY AND FT FEET/FOOT TBD TO DETERMINED <br /> ® FLOOR DRAIN RPBA FTG FOOTING TD TRENCH DRAIN <br /> EFFICIENCY. MINIMUM EFFICIENCY SHALL MEET TABLE C404.2 FV FLUSH VALVE TEMP TEMPERATURE <br /> 92 HIDDEN FLOOR DRAIN 2. PUBLIC LAVATORIES SHALL BE EQUIPPED WITH AN ASSE 1070 MIXING VALVE SET W <br /> TOB TOP OF BEAM <br /> t,A TRIPLE DUTY VALVE TO DELIVERY 110 F HOT WATER. G NATURAL GAS TOC TOP OF CONCRETE <br /> ��) ROOF DRAIN 3. NONCIRCULATING HOT WATER SYSTEMS WITHOUT AN INTEGRAL HEAT TRAP GA GAUGE TOD TOP OF DECK <br /> OVERFLOW DRAIN BALL VALVE MANUAL LEVER SHALL BE PROVIDED WITH HEAT TRAPS ON THE SUPPLY AND DISCHARGE PIPING. GAL GALLON TOJ TOP OF JOIST = oN <br /> 4. ELECTRIC WATER HEATERS IN UNCONDITIONED SPACES OR ON CONCRETE G.C. GENERAL CONTRACTOR TOS TOP OF SLABITOP OF STEEL a M FLOOR CLEANOUT pr*- GLOBE VALVE MANUAL LEVER GCO GRADE CLEANOUT TP TRAP PRIMER Q <br /> FLOORS SHALL BE PLACED ON INCOMPRESSIBLE R-10 INSULATION. Y <br /> O GRADE CLEANOUT 5. PROVIDE PIPE INSULATION PER ENERGY CODE SECTION C4032.9 AND GD GARAGE DRAIN T&P TEMPERATURE&PRESSURE BALANCE VALVE SPECIFICATION SECTION 22 07 00. GPF GALLONS PER FLUSH TYP TYPICAL ~ <br /> ® TRENCH DRAIN (PRESSURE INDEPENDENT) 6. INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE, GPM GALLONS PER HOUR OLU <br /> SUNLIGHT,MOISTURE AND WIND. PROVIDE JACKET AND ALUMINUM COVERS. GPM GALLONS PER MINUTE UL UNDERWRITERS LABORATORY J <br /> ® PUMP GW GREASE WASTE LINO UNLESS NOTED OTHERWISE m W <br /> �I 0-1 <br /> WALL CLEANOUT ADHESIVE TAPE IS NOT PERMITTED. UR URINAL > <br /> 7. ALL PIPE AND WRAP INSULATION SHALL BE LABELED WITH ITS THICKNESS AND W <br /> UP TO CLEANOUT �M METER INSULATING VALUE R OR K. H HEIGHT � _ <br /> HB HOSE BIBB V VENT(S) Q Q <br /> 8. THE MAXIMUM ALLOWABLE PIPING LENGTH FROM THE NEAREST SOURCE OF HOT LU <br /> FUNNEL DRAIN O METER WATER TO THE TERMINATION OF THE FIXTURE SUPPLY SHALL COMPLY WITH HBVB HOSE BIBB VACUUM BREAKER V VOLT 0 UJ <br /> HD HEAD VERT VERTICAL 0 S <br /> Y C404.3 HP HORSEPOWER VFD VARIABLE FREQUENCY DRIVE Q U) <br /> 9. CIRCULATING HOT WATER PUMPS OR HEAT TRACE SHALL BE EQUIPPED WITH < O fn <br /> AUTOMATIC TIMERS. HS HAND SINK VIB VALVE-IN-BOX 0-1Q <br /> HW HOT WATER VTR VENT THROUGH ROOF O m 0- <br /> STANDPFUNNELIPE DRAIN HX HEAT EXCHANGER m m 0 <br /> W WASTE/WATER O <br /> IE INVERT ELEVATION W/ WITH <br /> IN INCH/INCHES W/IN WITHIN <br /> W/O WITHOUT <br /> LEED NOTES - PLUMBING KW KILOWATT/KILOWATTS WC WATER CLOSET REVISION DATE REASON FOR ISSUE <br /> PLUMBING FIXTURE CONNECTION SCHEDULE WCO WALL CLEANOUT <br /> 2 09.20.22 GMP ADDENDUM <br /> WATER WASTE 1. THIS PROJECT WILL BE CERTIFIED IN ACCORDANCE WITH THE LAV LAVATORY WH WATER HEATER <br /> PIPE SUE FIXTURE FIXTURE REQUIREMENTS OF LEED V4 FOR NEW CONSTRUCTION. LBS POUNDS WPD WATER PRESSURE DROP <br /> W <br /> MARK FIXTURE C.W H.W WASTE VENT UNITS UNITS REMARKS LEED SPECIALIST IS RDI: 503 467 4710. LF LINEAL FOOT WT WEIGHT <br /> WC-1 WATER CLOSET 1" 3" 2" 5 4 FLOOR MOUNT FLUSH VALVE,ADA 2. CONTRACTOR MUST COORDINATE ADDITIONAL LEED COMMISSIONING LTG LIGHTING <br /> WC-2 WATER CLOSET 1" 3" 2" 5 4 FLOOR MOUNT FLUSH VALVE.ADA REQUIREMENTS WITH RWDI PRIOR TO SUBMITTING PRICING LWT LEAVING WATER TEMPERATURE YCO YARD CLEANOUT <br /> LAV-1 LAVATORY 1/2" 1/2" 1-12" 1-1/2" 1 1 WALL MOUNT ADA AND INCLUDE THOSE REQUIREMENTS IN ADDITION TO THE REQUIREMENTS SDCI APPROVAL STAMP <br /> LAV-2 LAVATORY 1/2" 1/2" 1-12" 1-1/2" 1 1 WALL MOUNT ADA OF SECTION 23 08 00. <br /> LAV-3 LAVATORY 1/2" 1/2" 1-12" 1-1/2" 1 1 UNDERMOUNT ADA 3. CONTRACTOR MUST COORDINATE LEED REQUIREMENTS <br /> S-1 SINK 1/2" 1/2" 2" 1-1/2" 2 1 2 SINK ADA WITH RWDI AND THE GENERAL CONTRACTOR <br /> S-2 SINK 1/2" 1/2" 2" 1-1/2" 2 2 SINK ADA AT THE BEGINNING OF THE CONSTRUCTION PHASE. <br /> S-3 SINK 1/2" 1/2" 2" 1-1/2" 2 2 SINK ADA 4. PROJECT INCLUDES ENERGY METERING FOR ANY INDIVIDUAL <br /> S-4 SINK 1/2" 1/2" 2" 1-1/2" 2 2 SINK ADA END USES THAT REPRESENT 10 PERCENT OR MORE OF THE <br /> S-5 SINK 1/2" 1/2" 2" 1-1/2" 2 2 SINK ADA TOTAL ANNUAL ENERGY CONSUMPTION OF THE BUILDING. <br /> S-6 SINK 1/2" 1/2" 2" 1-1/2" 2 2 SINK ADA MECHANICAL CONTRACTOR WILL PROVIDE GAS SUBMETERS <br /> SHIA SHOWER 1/2" 1/2" 2" 1-1/2" 2 2 ADA THAT REPORT TO AN ENERGY METERING DASHBOARD. <br /> SH-2 SHOWER 1/2" 1/2" 2" 1-1/2" 2 2 5. CONTRACTOR MUST COMPLY WITH WASTE MANAGEMENT <br /> SH-3 SHOWER 1/2" 1/2" 2" 1-1/2" 2 2 ADA PRACTICES AS SET FORTH IN THE SPECIFICATIONS. COVER <br /> SH4 SHOWER 1/2" 1/2" 2" 1-1/2" 2 2 ADA <br /> SS SERVICE SINK 1/2" 1/2" 3" 1-1/2" 3 3 MOP SINK 6. ALL MECHANICAL SEALANTS,ADHESIVES,AND COATINGS SHEET <br /> DF DRINKING FOUNTAIN 1/2" 1-1/2" 1-1/2" 0.5 0.5 HI-LOW MUST COMPLY WITH LEED V4 REQUIREMENTS FOR LOW <br /> SV SERVICE VALVE 1/2" 0.5 EMITTING MATERIALS. <br /> LB LAUNDRY BOX 1/2" 1/2" 2" 1-1/2" 3 6 7. CONTRACTOR MUST COMPLY WITH CONSTRUCTION IAQ <br /> DB-1 DRAIN BOX - - 2" 1-1/2" - 2 1 MANAGEMENT PLAN. GMP SET <br /> FDA FLOOR DRAIN 2" 1-1/2" EMERGENCY <br /> FD-2 FLOOR DRAIN 2" 1-1/2" 2 WITH FUNNEL S. THIS PROJECT MUST COMPLY WITH LEED V4 CREDIT E09, A B <br /> FD-3 FLOOR DRAIN 2" 1-1/2" EMERGENCY ACOUSTIC PERFORMANCE. <br /> FS FLOOR SINK 3" 1-1/2" 2 9. GAS FIRED EQUIPMENT MUST BE CLOSED COMBUSTION. <br /> GD GARAGE DRAIN - 4" 2 ROUTED TO OIUWATER SEPARATOR DATE PROJECT NUMBER <br /> HB-1 HOSE BIBB 3/4" 2.5 FREEZE-PROOF D C o® 09.20.2022 21016 <br /> HB-2 HOSE BIBB 3/4" 2.5 FREEZE-PROOF ROOF HYDRANT ^ SHEET NUMBER <br /> HB-3 HOSE BIBB 3/4" 3/4" 2.5 FREEZE-PROOF HOT&COLD KEY PLAN <br /> City of Everett Permit Services 0.01 <br /> EVERETT Reviewed for Permit 04/15/2025 0 8 16 32 64 <br />