Laserfiche WebLink
�FI4, <br /> S O°F� tgd„p <br /> PLUMBING FIXTURE SCHEDULE E <br /> MARK ITEM MFR:MODEL DESCRIPTION MARK ITEM MFR:MODEL DESCRIPTION MARK ITEM MFR:MODEL DESCRIPTION 7106 <br /> 4'�0}mrfi°91?°6r <br /> WC-1 WATER WHITEHALL: FLOOR-MOUNT,LIGATURE RESISTANT FIXTURE, S-4 SINK ELKAY: 23-1/2"X 18-1/4"X 5-3/8",18 GAUGE 304 STAINLESS STEEL,UNDERMOUNT WH-1 WATER LOCHINVAR: 110 GAL.CAP.,ASME,459 GPH RECOVERY @ 100 DEG.F TEMP RISE, �toNpu oea <br /> CLOSET WH2142-ADA SIPHON JET,ELONGATED RIM,16 GAUGE 304 STAINLESS STEEL, (ADA) ELUHAD211555PD SINGLE BOWL.INSTALLED PER ADA REQUIREMENTS. WH-2 HEATER SWA40ON 399 MBH MODULATING NATURAL GAS INPUT, <br /> (ADA) -W-3-EGE10_12 SEAMLESS WELDED CONSTRUCTION,POWDER COATED,WHITE. PVC COMBUSTION AIR&GAS VENT,95%EFF., <br /> 1-1/2"BACK SPUD,INTEGRAL SEAT.17"RIM HEIGHT,WATERSENSE. 2000 LBS(WET),120 V/1 PHASE,15 AMPS. <br /> FAUCET ELKAY: LEVER HANDLE,SINGLE HOLE,PULL OUT SPRAY, EMERGENCY BOILER SHUTOFF TO BE PROVIDED BY DIV.26 <br /> SEAT INTEGRAL TO WATER CLOSET LKGT1042 1.75 GPM FLOW RATE,ADA <br /> MV-1 BUILDING SYMMONS: THERMOSTATIC MIXING VALVE,INTEGRAL CHECK STOPS,REMOVABLE <br /> FLUSH SLOAN: CONCEALED HYDRAULLICALLY OPERATED FLUSHOMETER DRAIN PERFORATED STRAINER WITH OFFSET TAILPIECE PER ADA MV-2 MIXING 7-100 STRAINER,BRONZE FINISH,WALL MOUNTED. <br /> VALVE "ROYAL" WITH PUSH BUTTON ACTUATOR,1.28 GPF,INSTALL ON OPEN VALVE A <br /> 9603-1.28 SIDE OF RESTROOM PER ADA REQUIREMENTS,WATERSENSE. <br /> S-5 ART SINK INTEGRAL WITH COUNTERTOP,BY OTHERS. CP CIRC.PUMP ARMSTRONG: 18 GPM @ 25'HEAD,2/5 HP,120 VOLT,ALL <br /> ACTUATOR SLOAN: METAL PUSH BUTTON PANEL MOUNT TYPE ASSEMBLY. E21.2 BRONZE STAINLESS STEEL SHAFT SLEEVE. LEAD FREE. 38 NORTHWEST DAVIS,SUITE 300 <br /> MBPM INCLUDE EASY ACCESS WALL BOX SLOAN WB-1-A. PROVIDE WITH AQUASTAT AND 24 HR TIMER PORTLAND,OR 97209 <br /> 503,245,7100 <br /> WC-2 WATER KOHLER: FLOOR-MOUNT, ELONGATED BOWL,16-7/8"HEIGHT,ADA, FAUCET WHITEHALL: HOT AND COLD SENSORED,0.5 GPM,120V PLUG IN TRANSFORMER. DIET EXPANSION AMTROL: 16"DIAMETER X 24"HIGH,FAB.STEEL,100 LBS(DRY),ASME RATED 1505 5TH AVE,SUITE 300 <br /> CLOSET K-96057 INSTALL FLUSH HANDLE TOWARDS OPEN SIDE OF RESTROOM WH3375-HC-SO LIGATURE RESISTANT. TANK ST-42VC-DD SEATTLE,WA 98101 <br /> (ADA) PER ADA. 206.576.1600 <br /> S-6 PATIENT LAUNDRY INTEGRAL WITH COUNTERTOP,BY OTHERS. FD-1 FLOOR ZURN: 2"C.I.BODY,5"DIA ADJ.NICKEL BRONZE STRAINER,TRAP PRIMER <br /> SEAT BEAMIS: WHITE PLASTIC,ELONGATED,OPEN FRONT,WITHOUT COVER. SINK DRAIN Z-415BZ TAPPING.PROVIDE TRAP PRIMERS FOR ALL INSTALLATIONS 1014 HOWARD STREET <br /> 1955 CT EXCEPT SHOWERS. SAN FRANCISCO,CA 94103 <br /> 415,252,7063 <br /> REFER TO FLOOR DRAIN DETAIL FOR DRAIN CONST./COVERING. <br /> FLUSH ZURN: 1.1 GPF,ADA,WATERSENSE. FAUCET WHITEHALL: HOT AND COLD SENSORED,0.5 GPM,120V PLUG IN TRANSFORMER. ©ANKROM MOISAN ARCHITECTS,INC. <br /> VALVE Z6000AV-ONE WH3375-HC-SO LIGATURE RESISTANT. FD-2 FLOOR ZURN: 2"C.I.BODY,7"DIA ADJ.NICKEL BRONZE STRAINER,TRAP PRIMER SIDER+BYERS ASSOCIATES,INC. <br /> DRAIN Z-415BZ TAPPING.PROVIDE TRAP PRIMERS FOR ALL INSTALLATIONS MECHANICAL AND r <br /> LAVA LAVATORY WHITEHALL: LIGATURE RESISTANT WALL MOUNT LAV, ADA,LIGATURE RESISTANT DRAIN. SH-1 SHOWER COMFORT 42"X37-1/2"X82"HIGH,ONE PIECE GEL-COATED FIBERGLASS, W/FUNNEL EXCEPT SHOWERS.PROVIDE WITH ZURN FUNNEL. ELECTRICAL <br /> WHD-BSN-MC PROVIDE WITH CARRIER.INSULATE DRAIN PIPING AND SUPPLIES (ADA) DESIGNS(CDX): GRAB BARS,SEAT,RECESSED RECEIVER FLANGES.BEFORE ORDERING REFER TO FLOOR DRAIN DETAIL FOR DRAIN CONST./COVERING. sz NICKERSON,SUITE 300 <br /> PER ADA.LIGATURE RESISTANT DRAIN. SSS 3682 BF VERIFY RIGHT OR LEFT HAND PLUMBING.INSTALL PER ADA. SEATTLE,WA 98109 <br /> FD-3 FLOOR WHITEHALL: 2"C.I.BODY,5"DIA ADJ.NICKEL BRONZE STRAINER,TRAP PRIMER 206.285.2966 <br /> FAUCET WHITEHALL: HOT AND COLD SENSORED,0.5 GPM,ADA,120V PLUG IN TRANSFORMER. SHOWER SYMMONS: 24"SLIDE BAR,ADA,1.5 GPM HAND HELD SHOWER HEAD, DRAIN WHFD-5RD-2NH TAPPING.PROVIDE TRAP PRIMERS FOR ALL INSTALLATIONS <br /> WH3375-HC-SO ELECTRIC OUTLET TO BE LOCATED BEHIND LAV SHROUD BY DIV 26. HEAD T724-1.5 WATERSENSE. (LIGATURE EXCEPT SHOWERS.LIGATURE RESISTANT. <br /> RESISTANT) REFER TO FLOOR DRAIN DETAIL FOR DRAIN CONST./COVERING. <br /> LAVATORY POWERS: THERMOSTATIC MIXING VALVE,INTEGRAL CHECKS,3/8"INLET SHOWER SYMMONS: PRESSURE BALANCING MIXING VALVE,INTERGRAL STOPS, <br /> MIXING VALVE LFG480 AND OUTLET,MUST COMPLY WITH ASSE 1070.MINIMUM 0.25 GPM FLOW. VALVE 4700-X ADA. GO GARAGE JAY R SMITH: MEDIUM DUTY FLOOR DRAIN,4"BODY,GALVANIZED CAST IRON Cei PASS <br /> 0 INSTALL BEHIND LAV SHROUD. DRAIN 211 O-U STRAINER,SEDIMENT BUCKET,8"DIAMETER,VANDAL PROOF <br /> DRAIN GRID STRAINER GRATE. REFER TO FLOOR DRAIN DETAILLAV-2 LAVATORY KOHLER: 21-15/6"X 19-3/4",WALL MOUNT,SHROUD,VIT.CHINA,ADA,INTEGRAL FOR DRAIN CONST.WOR COVERING. � 1LK-1999-1 OVERFLOW,SINGLE HOLE,WHITE.PROVIDE CARRIER.SEE ARCH. SH-2 SHOWER FREEDOM: 62.375"X38.25"X4.5"ONE PIECE SHOWER PAN.ADA. L�L <br /> FOR MOUNTING HEIGHTS.PROVIDE GRID STRAINER DRAIN.INSULATE (PATIENT) APF6238BFPANC PROVIDE WITH WHITEHALL LIGATURE RESISTANT SHOWER <br /> DRAIN PIPING AND SUPPLIES PER ADA. DRAIN STRAINER AND OATEY 42150 DRAIN BODY. OSS OIL/SAND OLDCASTLE PRECAST:450 GAL.HOLDING CAPACITY,PREFORMED CONCRETE CONSTUCTION, <br /> SEPARATOR 660-SA 4"INLET&OUTLET W/SAMPLING TEES, RATED COVER LET U S <br /> FAUCET SLOAN: SENSORED,ADA,SINGLE HOLE,0.35 GPM,MIXER,120 V PLUG IN SHOWER BESAFEPROD LIGATURE-RESISTANT,RESSURE BALANCING VALVE PROVIDE SUFFICIENT RISER EXTENSIONSS T TO MAKE <br /> EAF-200 TRANSFORMER.ELECTRIC OUTLET TO BE LOCATED BEHIND LAV VALVE SV230 CHROME PLATED SOLID BRASS,INTEGRAL CHECK VALVES COVER FLUSH W/FINISH FLOOR,INTERNAL BAFFLES. <br /> SHROUD BY DIV 26. COORDINATE WATER PROOFING BEFORE ORDERING. <br /> SHOWERHEAD BESAFEPROD LIGATURE-RESISTANT,1.75 GPM,WATERSENSE development partners <br /> LAVATORY POWERS: THERMOSTATIC MIXING VALVE,INTEGRAL CHECKS,3/8"INLET SH340 CHROME PLATED SOLID BRASS RD ROOF ZURN: 15"DIA.C.I.BODY,3"PIPE SIZE,ALUM.DOME,UNDER- <br /> MIXING VALVE LFG480 AND OUTLET,MUST COMPLY WITH ASSE 1070.MINIMUM 0.25 GPM FLOW. DRAIN Z-100-C-R DECK CLAMP.OMIT DOMES WHEN UNDER PAVERS <br /> INSTALL BEHIND LAV SHROUD. SH-3 SHOWER COMFORT 62"X 33"X 78-3/4"HIGH,ONE PIECE GEL-COATED, <br /> (ADA) DESIGNS(CDX): FIBERGLASS, OD ROOF ZURN: 15"DIA.C.I.BODY,3"PIPE SIZE,ALUM.DOME,UNDER- <br /> LAV-3 LAVATORY KOHLER: 19-13/16 X 15-5/8",UNDERMOUNT,VIT.CHINA,ADA,INTEGRAL SSS 6233BF.75 FOLD DOWN SEAT AND GRAB BARS, DRAIN Z-100-C-R-W2 DECK CLAMP. 2"HIGH DAM.OMIT DOMES WHEN UNDER <br /> K-2882 OVERFLOW,WHITE.PROVIDE GRID STRAINER DRAIN.INSULATE L-BAR BEFORE ORDERING VERIFY RIGHT OR PAVERS. <br /> DRAIN PIPING AND SUPPLIES PER ADA. LEFT HAND PLUMBING.INSTALL PER ADA. <br /> SPA ELEVATOR WEIL: SIMPLEX SUBMERSIBLE,BRONZE IMPELLER,1 HP,1750 RPM <br /> FAUCET SLOAN: SENSORED,ADA,SINGLE HOLE,0.35 GPM,MIXER,120 V PLUG IN SHOWER SYMMONS: 24"SLIDE BAR,ADA,1.5 GPM HAND HELD SHOWER HEAD, SUMP PUMP 1413-2" 120 VOLT/1 PHASE,50 GPM @ 25 FEET HEAD,MODEL 8230 <br /> EAF-200 TRANSFORMER.ELECTRIC OUTLET UNDER COUNTERTOP BY DIV 26. HEAD T724-1.5 WATERSENSE. FLOAT SWITCHES WITH SIDEWALL MOUNTING BRACKET. <br /> MODEL 810OK7126 DISCRIMINATING LIQUID SENSOR. <br /> LAVATORY �LFG480t) <br /> THERMOSTATIC MIXING VALVE,INTEGRAL CHECKS,318" SHOWER SYMMONS: PRESSURE BALANCING MIXING VALVE,INTERGRAL STOPS, <br /> MIXING VALVE INLETS AND OUTLET,INSTALL EXPOSED UNDER SINK. VALVE 4700-X ADA. CONTROLS WEIL: UL LISTED CONTROL PANEL,MAGNETIC CONTACTOR,TOA SWITCH, <br /> MUST COMPLY WITH ASSE 1070.MINIMUM 0.25 GPM FLOW. 8109-NEMA 4X DEAD FRONT DESIGN,HWA HORN AND ALARM CONTACT. <br /> DRAIN GRID STRAINER DISCRIMINATING LIQUID SENSOR CONTROLS, <br /> S-1 SINK ELKAY: 23-1/2"X 18-1/4"X 5-3/8",18 GAUGE 304 STAINLESS STEEL,UNDERMOUNT PROVIDE ADDITIONAL POWER CABLE LENGTHS <br /> (ADA) ELUFIAD211555PD SINGLE BOWL.INSTALLED PER ADA REQUIREMENTS. SH-4 SHOWER FREEDOM: 62.375"X38.25"X4.5"ONE PIECE SHOWER PAN.ADA. AS NEEDED,120 V/1 PHASE.(PANEL LOCATED IN ROOM 154, <br /> (PATIENTADA) APF6238BFPANC PROVIDE WITH WHITEHALL LIGATURE RESISTANT SHOWER SEE FLOOR PLANS) <br /> DRAIN STRAINER AND OATEY 42150 DRAIN BODY. <br /> FAUCET ELKAY: GOOSENECK,SINGLE HANDLE,SINGLE HOLE,PULL DOWN SPRAY, CONTACT COLUMBIA HYDRONICS 360-883-2600 <br /> LKAV4032 1.5 GPM FLOW RATE,ADA SHOWER BESAFEPROD LIGATURE-RESISTANT,RESSURE BALANCING VALVE,ADA, <br /> VALVE SV230 CHROME PLATED SOLID BRASS,INTEGRAL CHECK VALVES SP-2 ELEVATOR WEIL: SIMPLEX SUBMERSIBLE,BRONZE IMPELLER,2 HP,3450 RPM <br /> DRAIN BASKET STRAINER.INSULATE DRAIN AND SUPPLIES PER ADA. SUMP PUMP 2443-2" 208 VOLT/1 PHASE,100 GPM @ 30 FEET HEAD,MODEL 8230 W <br /> HANDHELD WHITEHALL: LIGATURE-RESISTANT,1.5 GPM,HANDHELD SHOWER HEAD FLOAT SWITCHES WITH SIDEWALL MOUNTING BRACKET. N <br /> SHOWER HEAD WHCHS MODEL 810OK7126 DISCRIMINATING LIQUID SENSOR. <br /> S-2 SINK ELKAY: 25"X 21"X 6-1/2",18 GAUGE 304 STAINLESS STEEL,TOP MOUNTED <br /> LRAD252165 SINGLE BOWL.FULLY COATED UNDERSIDE.3 HOLES ON 4"CENTERS. SV SERVICE SIOUX CHIEF: 1/2"SERVICE STOP FOR SUPPLY WATER,WATER HAMMER CONTROLS WEIL: UL LISTED CONTROL PANEL,MAGNETIC CONTACTOR,TOA SWITCH, O <br /> N <br /> INSTALLED PER ADA REQUIREMENTS. VALVE 696-G1010MF ARRESTOR,OUTLET BOX,5-3/4"X 7-1/4"BOX. 8109-NEMA 4X DEAD FRONT DESIGN,HWA HORN AND ALARM CONTACT. 00 <br /> DISCRIMINATING LIQUID SENSOR CONTROLS, �/ Q <br /> FAUCET CHICAGO: 2-3/8"LEVER HANDLES.GOOSENECK SWIVEL SPOUT.8"CENTERS. SS SERVICE KOHLER FLOOR STYLE 28"X 28"X 13",CORNER FLOOR MOUNT PROVIDE ADDITIONAL POWER CABLE LENGTHS U >j <br /> 786-E35-369ABCP 1.5 GPM FLOW RATE,ADA SINK K-6710 AS NEEDED,208 V/1 PHASE.(PANEL LOCATED IN ROOM 154, F <br /> SEE FLOOR PLANS) 0 (- <br /> DRAIN BASKET STRAINER.INSULATE DRAIN AND SUPPLIES PER ADA. FAUCET T&S BRASS WALL MOUNT WITH BRACE,VACUUM BREAKER,BUCKET J LU <br /> B-0665-CR-BSTR HOOK,3/4"HOSE THREAD,INTEGRAL CHECKS VALVES. CONTACT COLUMBIA HYDRONICS 360-883-2600 m W <br /> S-3 EXAM SINK ELKAY: 15"X 15"X 6-1/8",18 GAUGE 304 STAINLESS STEEL,TOP MOUNTED LB LAUNDRY OATEY: 11-3/4"X 10-1/8",HIGH-IMPACT POLYSTYRENE BOX,PROVIDE GI GREASE SCHIER: 75 GPM POLYETHYLENE GREASE INTERCEPTOR, LU = <br /> BLR1560 SINGLE BOWL,FULLY COATED UNDERSIDE,2 HOLES ON 4"CENTERS, BOX QUADTRO TWO(2)3/4"QUARTER TURN BALL VALVES(1 HOT,1 COLD) INTERCEPTOR GB-75 46"X 32"X 38-1/2",130 LBS(DRY),PROVIDE WITH RISER Q Q Q <br /> INSTALL PER ADA REQUIREMENTS. OUTLET BOX WITH HAMMER ARRESTORS.PROVIDE 2"WASTE CONNECTION EXTENSIONS FOR LID TO BE INSTALLED FLUSH WITH GRADE. LU <br /> PROVIDE WITH H-20 RATED CAST IRON COVER. ❑ 2 <br /> FAUCET CHICAGO: WRIST BLADE HANDLES.GOOSENECK SWIVEL SPOUT.4"CENTERS. OF WATER ELKAY: HI-LOW TWO STATION,ADA COOLER WITH BOTTLE FILLING a0 fn <br /> 895-317GN2AE35ABCP 1.5 GPM FLOW RATE,ADA FOUNTAIN LZWS-LRPBM28K STATION,FILTERED,8 GPH CHILLED WATER, FS FLOOR ZURN: 12"X12"X6",CAST IRON BODY WITH WHITE ACID RESISTANT PORCELAIN, 0-1 < <br /> 115V/1PH. SINK Z1900-3 DOME STRAINER,1/2 GRATE.PROVIDE TRAP PRIMER.REFER TO FLOOR ON 03 a <br /> W <br /> DRAIN PERFORATED STRAINER WITH OFFSET TAILPIECE PER ADA DRAIN DETAIL FOR DRAIN CONST.AND/OR COVERING. N O <br /> onHB-1 EXTERIOR WOODFORD: FREEZE PROOF TYPE,AUTOMATIC DRAINING,WALL BOX,LOOSE KEY. co U <br /> HOSE BIBB B65 HANDLE,VACUUM BREAKER. <br /> gHB-2 ROOF WOODFORD: FREEZE PROOF TYPE ROOF HYDRANT,3/4"INLET,BACKFLOW REVISION DATE REASON FOR ISSUE <br /> HYDRANT SRH-MS PREVENTER.PROVIDE WITH MOUNTING SYSTEM. 2 09,20,22 GMP ADDENDUM <br /> HB-3 HOT&COLD WOODFORD: FREEZE PROOF TYPE,3/4"INLETS,BACKFLOW PREVENTER. <br /> HOSE BIBB C22 PROVIDE WITH LOOSE KEY CONTROLS IN LIEU OF WHEEL HANDLES. <br /> SDCI APPROVAL STAMP <br /> NOTES AND <br /> SCHEDULES <br /> GMP SET <br /> A B <br /> \\\7\\\\7 <br /> DME] C DATE PROJECT NUMBER <br /> to® 09.20.2022 21016 <br /> SHEET NUMBER <br /> KEY PLAN <br /> L City of Everett Permit Services P O.02 <br /> EVERETT Reviewed for Permit 04/15/2025 0 8 16 32 64 <br />