Laserfiche WebLink
1 2 1 3 1 4 1 5 s 1 7 1 8 1 9 10 1 11 <br /> x RECEPTACLE TYPES RECEPTACLES WORK DEFINITION ABBREVIATIONS PROJECT DETAILS tgb architects <br /> (t,AC MOUNTED 3'ABOVE COUNTER BACKSPLASH 0 0 DUPLEX, 120V FLAG NOTE A,AMP AMPERE KWH KILOWATT HOUR PROJECT SCOPE: <br /> }y ABV ABOVE LED LIGHT EMITTING DIODE DEMOLITION AND REPLACEMENT OF EXISTING CT EQUIPMENT LOCATED IN CT <br /> D DEDICATED CIRCUIT 0 0 DOUBLE DUPLEX, 120V AC 3"ABOVE COUNTER LS LIFE SAFETY ROOM 200.02. t 425.778.1530 21911 76th Ave W.Ste 210 <br /> REVISION IDENTIFICATION BACKSPLASH LTG LIGHTING f 425.774.7803 Edmonds WA 98026 <br /> G GROUND FAULT CIRCUIT INTERRUPTER(GFCI) ®® DUPLEX, 120V,CEILING MOUNTED ACH ABOVE COUNTER HEIGHT LTS LENGTH ONLY TO SCALE PROJECT ADDRESS: info@tgbarchitecls.com <br /> ®® DOUBLE DUPLEX, 120V,CEILING MOUNTED EQUIPMENT IDENTIFICATION AFCI ARC—FAULT CIRCUIT LV LOW VOLTAGE PROVIDENCE REGIONAL CANCER PARTNERSHIP www.tgbarchitects.com <br /> INTERRUPTING MAG MAGNETIC 1717 13TH ST. <br /> AFF ABOVE FINISHED FLOOR MAX MAXIMUM EVERETT,WA 98201 <br /> # AG ABOVE GRADE MCB MAIN CIRCUIT BREAKER <br /> DETAIL REFERENCE AHJ AUTHORITY HAVING MCC MOTOR CONTROL CENTER ENGINEERING CONTACT: <br /> # JURISDICTION MH MANHOLE EBD SERVICES <br /> y S AC AMPERE INTERRUPTING MIN MINIMUM JACK GLOVER <br /> LIGHT FIXTURES CIRCUITS CAPACITY MLO MAIN LUGS ONLY 206-413-6095 EXT 9 <br /> AL ALUMINUM MM MULTIMODE JACK.GLOVER®EBD—SERVICES.COM <br /> pa LOWER—CASE LETTER DENOTES SWITCH LEG RACEWAY CONCEALED IN CEILING OR WALL SECTION REFERENCE AM AMMETER MTD MOUNTED <br /> 0 ANSI RECESSED,DTS EXISTING RACEWAY ### STANDAMERI NATIONAL MW MICROWAVE <br /> STANDARDS <br /> p <br /> STANDARDS INSTITUTE N NEUTRAL EBD <br /> EVIDENCE <br /> A/V AUDIO/VISUAL NC NORMALLY CLOSED BASED <br /> 4 4 WALL—MOUNTED,LTS ————— RACEWAY BELOW SLAB OR UNDERGROUND N ATS AUTOMATIC TRANSFER NEC NATIONAL ELECTRICAL CODE GENERAL NOTES. o0 <br /> SWITCH NEMA NATIONAL ELECTRICAL DESIGN <br /> E) RACEWAY UP PROJECT NORTH REFERNCE AWG AMERICAN WIRE GAUGE MANUFACTURERS 1. ALL ELECTRICAL WORK AND MATERIALS ARE TO COMPLY WITH THE LATEST S E R V I C E S <br /> 00 00 RECESSED DOWNUGHT,DTS BAS BUILDING AUTOMATION ASSOCIATION REQUIREMENTS OF ALL APPLICABLE CITY,COUNTY,AND STATE CODES AS <br /> 9 RACEWAY DOWN SYSTEM NFPA NATIONAL FIRE PROTECTION WELL AS THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY <br /> N/A EXIT SIGN,FILLED SIDE ILLUMINATED,DIRECTIONAL ASSOCIATION <br /> BKR BREAKER THE LOCAL AUTHORITY HAVING JURISDICTION. <br /> ARROWS AS INDICATED,TUTS ———�] RACEWAY STUB—OUT WITH BUSHING NEW WORK CAN COMMUNITY ACCESS NIC NOT IN CONTRACT <br /> TELEVISION NO NORMALLY OPEN 2. COORDINATE EXACT LOCATIONS OF ALL ELECTRICAL DEVICES WITH <br /> [!0 X—RAY ON LAMP CIRCUIT CONTINUATION EXISTING CONDITIONS <br /> CO CONDUIT ONLY OCPD OVERCURRENT PROTECTIVE <br /> HOMERUN CB CIRCUIT BREAKER DEVICE <br /> FUTURE WORK CCTV CLOSED CIRCUIT TELEVISIONOPER OPERATER/OPERABLE <br /> 0 JUNCTION BOX � xxx DEMOLISH EXISTING CKT CIRCUIT OPOI OWNER PROVIDED OWNER CLG CEILING INSTALLED STANDARD MOUNTING HEIGHTS <br /> ® PULL BOX CM CELING MOUNTED PB PULLBOX <br /> COMM COMMUNICATIONS PNL PANEL,PANELS LOCATE DEVICES AS NOTED BELOW UNLESS OTHERWISE INDICATED.OUTLET b� >r <br /> U CONTROL POS POSITION/POINT OF SALE a <br /> EQUIPMENT C OF C HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF <br /> COPPER PR PAIR D DATA PTS PNEUMATIC TUBE STATION THE OUTLET UNLESS OTHERWISE NOTED. <br /> y LIGHTING CONTROLS ONE-LINE DIAGRAM ® EQUIPMENT CONNECTION DC DIRECT CURRENT PWR POWER _ <br /> DIED DEDICATED R RACEWAY RECEPTACLES 18"VERTICALLY MOUNTED <br /> DEV DEVICE RO RACEWAY ONLY 57724�,cp <br /> $a LOWER—CASE LETTER DENOTES CIRCUIT CONTROLLED Q AVAILABLE FAULT CURRENT IDENTIFICATION CEP FUSED DISCONNECT DIV DIVISION RCP REFLECTED CEILING PLAN SWITCHES 43"VERTICALLY MOUNTED ,q,_ 1ST6�`" <br /> "'dstONAL '� <br /> O AMMETER ON DOWN RCPT RECEPTACLE CLOCK OUTLET 80" <br /> SINGLE—POLE SWITCH GROUND BAR,LENGTH TO SCALE DTS DRAWN TO SCALE REF REFRIGERATOR wloelzoza <br /> • • ARRESTOR,SURGE DW DISHWASHER SLV SLEEVE 72"TO TOP OF <br /> DIMMER SWITCH PANELBOARDS DWG DRAWING SM SINGLEMODE PANELBOARD IN BOX IS <br /> a ARRESTOR,LIGHTNING MOTOR CONNECTION,SINGLE—PHASE EF ENTRANCE FACILITY SMR SURFACE MOUNTED <68'HIGH,OTHERWISE <br /> $0 OCCUPANCY SENSOR SWITCH Ld AUTOMATIC TRANSFER SWITCH(ATS) ER EQUIPMENT RACEWAY PER NEC 404.8 <br /> Q MOTOR CONNECTION,THREE—PHASE ROOM/EMERGENCY ROOM SPECS SPECIFICATIONS INTERCOM 43" <br /> SWITCH <br /> BUSWAY END TAP SPD SURGE PROTECTIVE DEVICE FAC FIRErnAARM ELECICATER COOLER SSWWBD SWITCHBOARD CARD READER 43" <br /> FB FLOOR BOX TELECOM TELECOMMUNICATIONS TELECOM OUTLET,DESK HANDSET 18"VERTICALLY MOUNTED <br /> BUSWAY PLUG FBOIC FURNISHED BY OTHERS, TGB TELECOMMUN CATIONS <br /> ® TRANSFORMER INSTALLED BY CONTRACTOR GROUNDING BUSBAR TELECOM OUTLET,WALL HANDSET 43"VERTICALLY MOUNTED <br /> CAPACITOR FI FILM ILLUMINATOR TMGB TELECOMMUNICATIONS MAIN VOLUME CONTROLLER 43' <br /> FIRE ALARMC-1% CIRCUIT BREAKER ® ENCLOSED CIRCUIT BREAKER FO FIBER OPTICAL) GROUNDING BUSBAR <br /> FOC FACE OF COLUMN TR TELECOMMUNICATIONS ROOM FIRE ALARM PULL STATION 43" <br /> ® SMOKE DETECTOR e� CIRCUIT BREAKER, NETWORK PROTECTOR G,GND GROUND TV <br /> TELEVISIONAFF <br /> GF AUTO DOOR PUSHPLATE GD GARBAGE DISPOSAL TOP EDGE 96"BELOW <br /> CIRCUIT BREAKER,GA GEN GENERATOR UC UNDER COUNTER MINIMUM&6"BELOW <br /> GFI,GFCI GROUND FAULT CIRCUIT OF UNDER FLOOR FIRE ALARM AUDIBLE NOTIFACTION CEILING MINIMUM.(6' <br /> SPEAKER,WALL—MOUNTED&CEILING—MOUNTED CIRCUIT BREAKER, DRAWOUT MGAP MEDICAL GAS ALARM PANEL INTERRUPTER UG UNDER GROUND DEVICES MINIMUM BELOW CEILING <br /> XX } HH HAND HOLE UL UNDERWRITERS TAKES PRECEDENCE WHERE <br /> CIRCUIT BREAKER, DRAWOUT,MEDIUM VOLTAGE HP HORSEPOWER LABORATORIES BOTH REQUIREMENTS <br /> STROBE,WALL—MOUNTED&CEILING—MOUNTED <br /> HTR HEATER UON UNLESS OTHERWISE NOTED CANNOT BE MET.) <br /> s•'�--�J CIRCUIT BREAKER,THERMAL OVERLOAD OF INDEPENDENT DISTRIBUTION UTP UNSHIELDED TWISTED PAIR FIRE ALARM VISUAL& BOTTOM EDGE 80"AFF <br /> CIRCUIT BREAKER, MAGNETIC OVERLOAD FRAME V VOLT OR VOICE COMBINATION AUDIBLE/ASUAL MINIMUM&TOP EDGE 96" <br /> IHW INSTA—HOT WATER VEL VERIFY EXACT LOCATION NOTIFICATION DEVICES AFF MINIMUM. <br /> ® ENCLOSED CIRCUIT BREAKER DISPENSER W WIRE,WATT,OR WALLPHONE PROVIDENCE <br /> JB,J—BOX JUNCTION BOX WAP WIRELESS ACCESS POINT FIRE ALARM CONTROL PANEL 72"TO TOP OF PANEL <br /> X CONTACT,NORMALLY OPEN&NORMALLY CLOSED I <br /> TELECOM KV KILOVOLT WP WEATHERPROOF COLBY PET CT <br /> KVA KLOVOLT AMPERE XFMR TRANSFORMER <br /> O CONTACTOR KW KILOWATT 0 PHASE <br /> 0 DELTA 0 PROVIDE OUTLET BOX WITH 1"C TO ACCESSIBLE <br /> O ENGINE—GENERATOR CEILING LOCATION TURNED TOWARDS NEAREST <br /> COMMUNCKnONS CLOSET. PROVIDE CONDUIT WITH <br /> FUSE(ISOLATING) PULL STRING AND GROMMETED ENDS. SHEET LIST <br /> ®,�P FUSE OR CURRENT LIMITER p COMBO DATA AND VOICE OUTLET.PROVIDE OUTLET <br /> BOX WITH 1"C TO ACCESSIBLE CEILING LOCATION 1717 13th St <br /> FUSED SWITCH TURNED TOWARDS NEAREST COMMUNCATIONS CLOSET. SUBJECT TO FIEL SHEET NUMBER SHEET NAME <br /> D Everett,WA 98201 <br /> i GROUND PROVIDE CONDUIT WITH PULL STRING AND GROMMETED INSPECTION E0.00—PET SYMBOLS AND ABBREVIATIONS <br /> O KEY INTERLOCK ENDS. EO.01—PET ELECTRICAL SPECIFICATIONS <br /> O METER E1.00—PET COLBY CANCER CENTER—LEVEL 2—OVERALL PLAN <br /> POWER METER ` City of Everett Permit Review CONSTRUCTION <br /> PM EVERETT Status:Approved as Noted E1.11—PET LEVEL 2—PET CT ELECTRICAL DEMOLITION PLANS <br /> ,J, PUSHBUTTON NURSE CALL " 08/30/2024 3:37:55 PM E1.21—PET LEVEL 2—PET CT ELECTRICAL PLANS DOCUMENTS <br /> O RELAY r PATIENT TOILET STATION E1.22—PET LEVEL 2—PET CT ELECTRICAL RACEWAY PLAN <br /> E5.01—PET ELECTRICAL DETAILS <br /> RELAY,GFI STAFF ASSISTANCE STATION E6.01—PET LOAD CALCULATIONS AND PANEL SCHEDULES <br /> E7.01—PET NORMAL POWER ONE—LINE DIAGRAM <br /> SPD SURGE PROTECTIVE DEVICE ® NURSE MASTER STATION,WALL—MOUNTED& E7.02—PET EMERGENCY POWER ONE—LINE DIAGRAM <br /> .�. SWITCH,2—POLE CEILING—MOUNTED <br /> H 1�8( O DOME LIGHT,WALL—MOUNTED&CEILING—MOUNTED <br /> SWITCH,3—POLE '1J OO ZONE OCEILIME LIGHT, <br /> WALL MOUNTED& <br /> Q SYMBOLS AND <br /> THERMAL ELEMENT ABBREVIATIONS <br /> TRANSFORMER <br /> rvvv� <br /> TRANSFORMER,CURRENT ISSUANCE <br /> No. Description Date <br /> VOLTMETER PERMIT SET 07/0812024 <br /> OV <br /> ®H WATT HOUR METER <br /> y WYE <br /> PROJECT INFORMATION <br /> PROJECT NUMBER: B24-1032 <br /> PROJECT LEAD: JGG <br /> DRAWN BY: CMB <br /> a <br /> SHEET NO <br /> E0.00-PET <br /> 1 2 3 4 5 6 7 8 9 10 11 <br />