17 E MARINE VIEW DR 2019 Plans 2025-09-29 (3)
>
Address Records
>
E MARINE VIEW DR
>
17
>
Plans
>
17 E MARINE VIEW DR 2019 Plans 2025-09-29 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 2:02:10 PM
Creation date
9/29/2025 1:59:55 PM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
17
Permit
B1904-035
Year
2019
Notes
SOIL REMEDIATION RECYCLING FACILITY BY CADMAN
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Codes and Loads <br /> Snow Buildup <br /> WHEN MULTIPLE BUILDINGS ARE INVOLVED, SPECIFIC LOAD FACTORS FOR DIFFERING OCCUPANCIES, BUILDING DIMENSIONS, Shape Surface Description X Location Y Location Magnitude <br /> HEIGHTS, FRAMING SYSTEMS, ROOF SLOPES, ETC., MAY RESULT IN DIFFERENT LOAD APPLICATION FACTORS THAN Cadman 2 Roof: A Unbalanced Snow Load 1, Shifted Left Roof: A 0.0 £t 24.0 ft 12.9 psf <br /> INDICATED BELOW. SEE CALCULATIONS FOR FURTHER DETAILS. WIND LOADS ARE APPLIED TO OVERALL BUILDING ENVELOPE. 0.0 ft 0.0 ft 12.9 psf <br /> COMMON WALLS BETWEEN CONNECTED SHAPES ARE NOT SUBJECT TO EXTERNAL WIND LOADS. 150.0 ft 0.0 ft 12.9 psf <br /> City: Everett County: Snohomish State: Washington Country: United States 150.0 ft 24.0 ft 12.9 psf <br /> Building Code Cadman 2 Roof: B Unbalanced Snow Load 1, Shifted Right Roof: B 0.0 ft 24.0 ft 12.9 psf <br /> Building Code: 2015 International Building Code Structural: IOAISC - ASD Rainfall: I: 4.00 inches per hour 0.0 ft 0.0 ft 12.9 psf <br /> Building Risk/Occupancy Category: II (Standard Occupancy Structure) Cold Form: 12AISI -ASD f'c: 3000.00 psi Concrete 150.0 ft 0.0 ft 12.9 psf <br /> 150.0 ft 24.0 ft 12.9 psf <br /> Cadman 2 Roof: C Unbalanced Snow Load 1, Shifted Left Roof: C 0.0 ft 24.0 ft 12.9 paf <br /> Dead and Collateral Loads Material Dead Weight Roof Live Load 0.0 ft 0.0 ft 12.9 paf <br /> Collateral Grav ty:5.00 psf Roof Covering + Second. Dead Load: Varies Roof Live Load: 20.00 psf Reducible <br /> 51.0 ft 0.0 ft 12.9 psf <br /> Collateral Uplift: 3.00 51.0 ft 24.0 ft 12.9 psf <br /> p psf Frame Weight (assumed for seismic):5.00 psf - USR Cadman 2 Roof: C Snow Drift (from Wall 3, Shape Cadman 2) : Roof: C 0.0 ft 60.2 ft 70.0 psf <br /> Wind Load Snow Load Seismic Load 0.0 ft 0.0 ft 70.0 psf <br /> Wind Speed: Vult: 110.00 (Vaad: 85.21) mph Ground Snow Load: pg: 25.00 psf Lateral Force Resisting Systems using Equivalent Force Procedure 16.2 ft 0.0 ft 0.0 psf <br /> 16.2 ft 60.2 ft 0.0 paf The 'Envelope Procedure' s Used Flat Roof Snow: pe : ps: psf Mapped MCE Acceleration: Ss: 542.00 #g Cadman 2 Roof: D Unbalanced Snow Load 1, Shifted Right : Roof: D 0.0 ft 24.0 ft 12.9 psf Wind Exposure: C - Kz: 1.057 Design Snow (Sloped): pa: 18.90 psf Mapped MCE Acceleration: S1: 54.10 #g <br /> Parts Wind Exposure Factor: 1.057 Rain Surcharge: 0.00 Site Class: Stiff soil (D) 0.0 ft 0.0 ft 12.9 psf <br /> Wind Enclosure: Free Roof - Clear/Obstr Specified Minimum Roof Snow: 25.00 51.0 ft 0.0 ft 12.9 paf <br /> p psf (USR) Seismic Importance: Is: 1.000 <br /> . a Topographic Factor: Kzt: 1.0000 Exposure Factor: 1 Fully Exposed - Ce: 0.90 Design Acceleration Parameter: Sds: 0. 4 f <br /> Snow Importance: Is: 1.000 Design Acceleration Parameter: Shc: 0.5410 Cadman 2 Roof: D Snow Drift (from Wall 3, Shape Cadman 2) Roof: D 51.0 ft 0.51.0 ft 24 0 0 ft 12.9 pft 70.0 psf <br /> 10 <br /> NOT Windborne Debris Region Thermal Factor: Unheated - Ct: 1.20 Seismic Design Category: D <br /> 51.0 ft 60.2 ft 70.0 psf <br /> Base Elevation: 0/0/0 Ground / Roof Conversion: 0.70 Seismic Snow Load: 0.00 psf 34.B ft 60.2 ft 0.0 psf <br /> Primary Zone Strip Width: 2a: 42/6/0 # Snow Used in Seismic: 0.00 34.B ft 0.0 ft 0.0 psf <br /> Parts / Portions Zone StripWidth: a: 12/0/0 1. The Snow Buildup loading shown is in addition to the flat or sloped roof snow. <br /> Diaphragm Condition: Flexible 2. The X and Y Location dimensions are from the point of origin of each surface. <br /> Basic Wind Pressure: q: 27.63 psf Fundamental Period Height Used: 42/6/0 P <br /> Transverse Direction Parameters <br /> Ordinary Steel Moment Frames <br /> Redundancy Factor: Rho: 1.30 <br /> Fundamental Period: Ta: 0.5622 <br /> R-Factor: 3.50 <br /> Overstrength Factor: Omega: 2.50 <br /> Deflection Amplification Factor: Cd: 3.00 <br /> Base Shear: V: 0.2705 x W <br /> Longitudinal Direction Parameters <br /> Ordinary Steel Concentric Braced Frames <br /> Redundancy Factor: Rho: 1.30 <br /> Fundamental Period: Ta: 0.3329 <br /> R-Factor: 3.25 <br /> Overstrength Factor: Omega: 2.00 <br /> Deflection Amplification Factor: Cd: 3.25 <br /> Base Shear: V: 0.2913 x W <br /> Cadman 2 <br /> I Roof: D <br /> ` Cadman 2 <br /> Roof: C <br /> X \` <br /> `\ I <br /> Cadman 2 <br /> Roof: B <br /> Cadman 2 <br /> Roof: A <br /> WA <br /> I _ <br /> I <br /> I <br /> I <br /> 56 9Z <br /> I - <br /> 2ssroNMAL <br /> 04/09/2019 <br /> PERMIT SET-For Building Dept.Approval <br /> THE VP ENGINEER'S SEAL APPLIES ONLY TO THE THIS DRAWING,INCLUDING THE INFORMATION HEREON,REMAINS THE PROPERTY OF VP BUILDINGS. VP Buildings <br /> WORK PRODUCT OF VP AND DESIGN AND IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE CODES AND LOADS <br /> PERFORMANCE REQUIREMENTS SPECIFIED BY ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE.IT SHALL NOT BE MODIFIED, 3200 Players Club Circle Memphis TN 38125 <br /> VP.THE VP ENGINEER'S SEAL DOES NOT APPLY REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP <br /> TO THE PERFORMANCE OR DESIGN OF ANY BUILDINGS. BEV Euh w DE:-1-ON BUILDER CHG Building ems,Inc. .IOBNO <br /> OTHER PRODUCT OR COMPONENT FURNISHED THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD cusfOmER Cadman 18-0040735-01 <br /> BY VP EXCEPT TO ANY DESIGN OR QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, <br /> PERFORMANCE REQUIREMENTS SPECIFIED BY DETAILS REFERENCED IN THIS DRAWING,ALL APPLICABLE VP BUILDINGS ERECTION GUIDES,AND Everett,Washington VP BUILDINGS 04/08/2019 <br /> VP. INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,INCLUDING THE CORRECT USE OF PROJECT VRRS pRl1DEN DRAY HECK <br /> TEMPORARY BRACING. Cadman Everett Bldg 2 LND <br /> A BIueSDope Slea Company p� <br /> NTS Bu DBRaP 28103 NP ns- 2018.2b <br /> 2 <br /> 4/5/2019 10:56:21 p-ME Cadman 1- <br />