Laserfiche WebLink
DIGITAL INPUT 1 SHOWN. ANALOG INPUT 1 SHOWN. ANALOG INPUT 1 SHOWN. 4-20 mA ANALOG INPUT 1 SHOWN. ANALOG INPUT 1 SHOWN. DIGITAL OUTPUT 1 SHOWN. CONTROLLED DIGITAL OUTPUT 1 SHOWN. CONTROLLED <br /> SEE DRAWING FOR ACTUAL STATUS OR SEE DRAWING FOR ACTUAL SEE DRAWING FOR ACTUAL SENSOR SEE DRAWING FOR ACTUAL 2-10 VDC SEE DRAWING FOR ACTUAL 2-10 VDC SEE DRAWING FOR ACTUAL DEVICE SEE DRAWING FOR ACTUAL DEVICE <br /> INPUT AND TERMINAL ALARM CONTACT INPUT AND TERMINAL SENSOR CONTACT INPUT AND TERMINAL NUMBER. INPUT AND TERMINAL NUMBER. SENSOR INPUT AND TERMINAL NUMBER, SENSOR OUTPUT AND TERMINAL NUMBER. OUTPUT AND TERMINAL NUMBER. <br /> NUMBER. NUMBER. <br /> OR AI-1 499 OHM - + AI-1 x <br /> AI-1 + - A ti <br /> DI-1 AI-1 21 1 OR 1 DO-1 DO-1 PANEL FIELD <br /> RELAY <br /> t Vaux AI/AO AI/AO AI/AO N.O.11 N.0.:p 11 I <br /> BI AI/AO N.C.12 Q N.C.12 Q GND GNDtRESI <br /> GND GND COM13 COM13 <br /> GND GND 11 11 PANEL <br /> z PANEL PANEL LINE <br /> 13 —PANEL LINE 11 PANEL LINE LINE LINE PANEL LINE PANEL LINE <br /> ONE WIRE PER �, 1 <br /> PANEL FIELD PANEL FIELD 24 VDC PANEL FIELD 24 VAC PANEL FIELD 1 PANEL FIELD PANEL FIELD MODULE IF 24 VAC <br /> (note 3) 24 VAC JUMPERS ARE <br /> DETAIL A DETAIL B DETAIL C DETAIL D DETAIL E DETAIL F INSTALLED DETAIL G <br /> DRY CONTACT STATUS OR ALARM TWO WIRE SENSOR or CONTACT 2 WIRE 4-20 mA SENSOR 3 WIRE 2-10 VDC SENSOR 4 WIRE 2-10 VDC SENSOR RELAY CONTROL- INTERNAL PANEL RELAY RELAY CONTROL- RELAY IN FIELD <br /> ANALOG OUTPUT 1 SHOWN. ANALOG OUTPUT 1 SHOWN. ANALOG OUTPUT 1 SHOWN. DIGITAL INPUT 1 AND DIGITAL OUTPUT 1 34 POWER ANALOG OUTPUT 1 SHOWN. ANALOG INPUT 1 SHOWN. <br /> SEE DRAWING FOR ACTUAL OUTPUT ACTUATOR SEE DRAWING FOR ACTUAL OUTPUT ACTUATOR SEE DRAWING FOR ACTUAL OUTPUT AND SHOWN. SEE DRAWING FOR ACTUAL INPUT, TO MOTOR SEE DRAWING FOR ACTUAL SEE DRAWING FOR ACTUAL 4-20 mA <br /> AND TERMINAL NUMBER. AND TERMINAL NUMBER. TERMINAL NUMBER. OUTPUT AND TERMINAL NUMBERS. ON SMALL MOTORS J I OUTPUT AND TERMINAL VFD OR OTHER INPUT AND TERMINAL NUMBER. SENSOR <br /> AO-1 AO-1 ACTUATOR D0-1 DWRAP EVICE IRE THRU r NUMBER. CONTROL PANEL <br /> AO-1 I AI-1 499 OHM <br /> 1 + 1 ti 1 + l ti 1 N.0.11 TIMES. I STARTER 1 RESISTOR T 1 + <br /> AI/A0 N.C.12 0 I AO-1 <br /> AI/AO A]/AO DI-1 - � OR VFD 1 + - AI/AO <br /> COM13 <br /> VTRANkDUCER <br /> GND GND 0 GND —7 BI - AI/AO GND <br /> ONE WIRE PER 11PANEL MODULE IF 0/2-1Ovdc11PANEL LINE PANEL LINE ~LINE JUMPERS ARE 24 VAC PANEL GNU 11 —PANEL LINE 1 + F_PANEL <br /> J. ti DWAU.ED GND LINE <br /> 24 VAC PANEL FIELD 24 VAC PANEL FIELD 24 VAC PANEL FIELD 13 PANEL FIELD PANEL FIELD 24 VDC PANEL FIELD <br /> (note 3) (note 3) (note 3) <br /> DETAIL H DETAIL I DETAIL J DETAIL K DETAIL L DETAIL M <br /> 3 WIRE VALVE OR DAMPER ACTUATOR 4 WIRE VALVE OR DAMPER ACTUATOR 3 WIRE PNEUMATIC TRANSDUCER VERIS CONTROL RELAY WITH CURRENT STATUS 2 WIRE 0/2-10V CONTROL 3 WIRE 4-20 mA SENSOR <br /> DIGITAL OUTPUT 1 SHOWN. ANALOG INPUT 1 SHOWN. ANALOG OUTPUT 1 SHOWN. ACTUATOR <br /> SEE DRAWING FOR ACTUAL 2-POS SEE DRAWING FOR ACTUAL 4-2OmA VDC SEE DRAWING FOR ACTUAL <br /> OUTPUT AND TERMINAL NUMBER. 24V ACTUATOR INPUT AND TERMINAL NUMBER. SENSOR OUTPUT AND TERMINAL NUMBER. <br /> DO-1N11 AO-1 <br /> 499 OHM + - 1 ti 1 <br /> RELAY 1 1 RESIS OR <br /> AI/AO <br /> N.O,11 AI <br /> N.C.12 0 € GND 0 <br /> CoM13 GND 11 <br /> 11 ONE WIRE PER <br /> MODULE IF 1 IONE WIRE PER I . PANEL FIELD PANEL LINE JUMPERS ARE 24 VAC <br /> MODULE IF 24 VAC —PANEL LINE 1 ro PANEL FIELD INSTALLED 1 Z <br /> JUMPERS ARE 24 VAC PANEL LINE <br /> INSTALLED DETAIL N DETAIL 0 AI 1� PANEL FIELD <br /> 2-POS ACTUATOR CONTROL 4 WIRE 4-2OmA SENSOR DETAIL P 22awg, MAX WIRE <br /> 4 WIRE ACTUATOR WITH FEEDBACK LENGTH 130 FT(40m). MODULES MAY BE WIRED TOGETHER. <br /> 24VAC YEL NO T-TAPPING. EITHER IN THE SAME PANEL OR A <br /> POWER 79 <br /> DIFFERENT ROOM. <br /> 080 <br /> nm�.. <br /> 18awg, MAX <br /> CPO-10830A WIRE LENGTH CPO-10830A <br /> HONEYWELL 000 HONEYWELL 10 FT(3m). HONEYWELL <br /> CPO-PC400 T.1 Ta To EXCEL 800 GENERAL DETAIL NOTES... <br /> 000 0000000000000 w000006 00 0000000000000 w000006 00 1. THE 24 VAC POWER SOURCE REFERRED TO IN SOME DETAILS COMES FROM A <br /> i h'w w TRANSFORMER THAT MAY BE COMPLETELY SEPARATE OR IT MAY BE PART OF A <br /> STANDARD POWER SUPPLY THAT ALSO PROVIDES 24 VAC POWER TO THE <br /> CONTROLLER. LOOK ON THE CONTROL DRAWINGS TO DETERMINE THE TYPE AND <br /> 000000 0000 0000 000000 000000 0000 0000 000000 LOCATION. <br /> arm'wan �wm wan aB awao aman Bow awwe arm'wan Jnao wan aB anao amua Bow amwe <br /> 2. THE 24 VDC POWER SOURCE REFERRED TO IN SOME DETAILS COMES FROM A <br /> 000000 0000 00 8800 000000 000000 0000 00 0000 000000 SEPARATE DC POWER SUPPLY OR FROM A SEPARATE OUTPUT ON A STANDARD <br /> POWER SUPPLY THAT ALSO PROVIDES THE 24 VAC POWER TO THE CONTROLLER. <br /> LOOK ON THE CONTROL DRAWINGS TO DETERMINE THE TYPE AND LOCATION. <br /> 3. IF A SEPARATE AUX TRANSFORMER IS USE TO POWER THE FIELD DEVICES THEN <br /> CONNECT A JUMPER FROM THE COMMON SIDE OF THE AUX TRANSFORMER TO <br /> - TERMINAL 9 OF THE AI OR AO MODULE. <br /> NOTE <br /> THESE ARE JUST CABLE GUIDELINES. EXCEL 800 SPECIFIC DETAIL NOTES... <br /> CABLE PART# AND LENGTH TO BE SELECTED ON FIELD BASED DETAILS H AND I: <br /> ON THE SPECIFICATION AND INSTALLATION REQUIREMENT. ACTUATOR TERMINAL DESIGNATIONS WILL VARY. SEE CONTROL DRAWINGS FOR <br /> TERMINAL NUMBERS OR WIRE COLORS. <br /> DETAIL K: <br /> MOUNT THE VERIS STATUS SENSOR ON ONE PHASE OF THE STARTER WIRING GOING <br /> TO THE MOTOR BEING MONITORED. <br /> NOTES DETAILS F,G AND K: <br /> 1. REFER TO DEVICE INSTALLATION INSTRUCTIONS FOR THE DO CONTACT OUTPUTS ARE RATED FOR UP TO 250VAC AT 5 AMPS. <br /> COMPLETE WIRING INFORMATION. 12 AMPS TOTAL FOR THE SUM OF ALL CONTACTS. <br /> 2.SOME DETAILS ABOVE MAY NOT BE USED IN THIS <br /> SET OF CONTROL DRAWINGS. <br /> rn Bews WE m ROMN IN mwnm WE ACCEPTABILTTY Sa' 11z5.24 mu""` PC-400 AND I0830A WIRING DETAILS "" "r" '°" g"e0L "°` 11.25.24 <br /> 40-023 HBL EXPANSION POS 4,5,6 AHU-6L USB-027992 HWL VS 11.25.24 1185 0m"i� <br /> ,,�„ TM 11.25.24ME <br /> `E901-26 <br /> APPROVED BYDEPT. oni[ SB 11z5z4 <br /> awm_1V�J� TM 11.=4 BUILDING 40-023 <br /> JOB w0. car N0. <br /> ELECTRICAL MASTER EVERETT,WA owar» 40-023-ED01-26 <br />