Laserfiche WebLink
DIGITAL SIGNAL WIRED TO ANALOG SIGNAL WIRED TO ANALOG SIGNAL WIRED TO ANALOG SIGNAL WIRED TO ANALOG SIGNAL WIRED TO RELAY OUTPUT 1 SHOWN. TRIAC OUTPUT 1 SHOWN. RELAY OUTPUT 1 SHOWN. <br /> UNIVERSAL INPUT 1 SHOWN. UNIVERSAL INPUT 1 UNIVERSAL INPUT 1 SHOWN. UNIVERSAL INPUT 1 SHOWN. UNIVERSAL INPUT 1 SHOWN. SEE DRAWING FOR ACTUAL CONTROLLED SEE DRAWING FOR ACTUAL CONTROLLED SEE DRAWING FOR ACTUAL CONTROLLED <br /> SEE DRAWING FOR ACTUAL SHOWN. TYPE-1 SENSOR SEE DRAWING FOR ACTUAL 4-20 mA SEE DRAWING FOR ACTUAL 4-20 mA SEE DRAWING FOR ACTUAL 2SEN VDC OUTPUT AND TERMINAL NUMBER. DEVICE OUTPUT AND TERMINAL NUMBER. DEVICE OUTPUT AND TERMINAL NUMBER. DEVICE <br /> WIRE TO UI1 SENSOR <br /> INPUT AND TERMINAL NUMBER. DRY CONTACT SEE DRAWING FOR ACTUAL TO UI6 ONLY INPUT AND TERMINAL NUMBER. SENSOR INPUT AND TERMINAL NUMBER. SENSOR INPUT AND TERMINAL NUMBER. <br /> INPUT AND TERMINAL SENSOR <br /> NUMBER. _ CND 49 Y 1^' GND 49 e e e a R0223 a <br /> OR GND 49 499 OHM + - 1 ti RD2 23 <br /> rGNl <br /> 9 GND 49 UI2 48 - + U12 48 RESISTOR UI2 48 IN2 22 RELAY RELAY IN2 22 RELAY <br /> 8 UI248 UI147 UI147 UI147 RDI 2lrN e e JUI147 ONE GND 46 -- ONE GND 46 ,„,. GND 46 INI 20 —J JJUMPER JUMPER6 GHD 46 JUMPERPER PER PANEL PANEL ti t PANEL PANEL ti t <br /> 499 OHM LINE LINE —PANEL LINE <br /> PANEL PANEL 24 VAC 1 PANEL LINE 24 VAC 6 5 24 VAC <br /> PANEL LINE PANEL LINE 24 VDC - RESISTOR ~LINE 24 VAC 1 ~LINE POWER ^' POWER PANEL FIELD 24 VAC PANEL FIELD POWER <br /> POWER + POWER ro PANEL FIELD AUX POWER PANEL FIELD <br /> PANEL FIELD PANEL FIELD PANEL FIELD PANEL FIELD <br /> DETAIL A DETAIL B DETAIL C DETAIL D DETAIL E DETAIL F (RO) DETAIL F (T(� DETAIL G (R0) <br /> DRY CONTACT STATUS OR ALARM 2 WIRE SENSOR 2 WIRE 4-20 mA SENSOR 3 WIRE 4-20 mA SENSOR 4 WIRE 2-10 VDC SENSOR RELAY CONTROL- RELAY IN PANEL RELAY CONTROL- RELAY IN PANEL RELAY CONTROL- RELAY IN FIELD <br /> TRIAC OUTPUT 1 SHOWN. CONTROLLED ANALOG OUTPUT 1 SHOWN. ANALOG OUTPUT 1 SHOWN. ANALOG OUTPUT 1 SHOWN. UNIVERSAL INPUT 1 AND RELAY PANEL LINE UNIVERSAL INPUT 1 AND TRIAC —PANEL LINE <br /> SEE DRAWING FOR ACTUAL DEVICE SEE DRAWING FOR ACTUAL SEE DRAWING FOR ACTUAL SEE DRAWING FOR ACTUAL OUTPUT 1 SHOWN.SEE DRAWING OUTPUT 1 SHOWN.SEE DRAWING <br /> OUTPUT AND TERMINAL NUMBER. OUTPUT AND TERMINAL NUMBER. OUTPUT AND TERMINAL NUMBER. ACTUATOR OUTPUT AND TERMINAL NUMBER. FOR ACTUAL INPUT,OUTPUT AND ON SMALL MOTORS FOR ACTUAL INPUT,OUTPUT AND ON SMALL MOTORS <br /> ACTUATOR 3P POWER 30 POWER <br /> TERMINAL NUMBERS. WRAP WIRE THHU TERMINAL NUMBERS. WRAP WIRE 1HRu <br /> DEVICE THREE TIMES. TO MOTOR DEVICE THREE TIMES. TO MOTOR <br /> 24 O 35 N 24 VAC J <br /> RELAY A0234 $4GND <br /> R02 23 POWER r rN r+ 3 ti ACTUATOR IN2 22 24V-35 GND 33 <br /> A0234 A0132 2 1 M R0121 STARTER STARTER <br /> GND 33 1 BR<7 1 + BIN1 20 - OR VFD - O OR VFD <br /> TN 7 AOI 32 �, E-P GND 49 GND 49 6 5 <br /> 6 5 <br /> 24 VAC 24V TRANSDUCER ^PANEL <br /> ui148 uIIa7 24 VAC <br /> 24 VAC PANEL LINE 24V- 4 GND PANEL LINE POWER <br /> 3 PANEL LINE LINE GND 46 J GN➢ a6 J <br /> AUX POWER ENSURE VA RATING PANEL FIELD a e <br /> PANEL FIELD ON TERMINAL 3/4 PANEL FIELD PANEL FIELD PANEL FIELD PANEL FIELD <br /> DETAIL G (TO) ARE ADEQUATE DETAIL H DETAIL I DETAIL J DETAIL K (R0) DETAIL K (TO) <br /> RELAY CONTROL- RELAY IN FIELD 3 WIRE VALVE OR DAMPER ACTUATOR 4 WIRE VALVE OR DAMPER ACTUATOR 3 WIRE PNEUMATIC TRANSDUCER VERIS CONTROL RELAY WITH CURRENT STATUS VERIS CONTROL RELAY WITH CURRENT STATUS <br /> ANALOG OUTPUT 1 SHOWN. VFD OR OTHER RELAY OUTPUT 1 SHOWN. <br /> SEE DRAWING FOR ACTUAL SEE DRAWING FOR ACTUAL CONTROLLED <br /> 0 �� CONTROL PANEL OUTPUT AND TERMINAL OUTPUT AND TERMINAL NUMBER. DEVICE <br /> NUMBER. <br /> tooloo <br /> - + ti 1 COMFORTPOINT CPO-R CONTROLLER GENERAL DETAIL NOTES$IGNl <br /> RD2 23 IN2 22 RELAY 1. THE 24 VAC POWER SOURCE REFERRED TO IN SOME DETALS COMES FROM A TRANSFORMER OTHER <br /> ��� ROI 21 e a THAN THE ONE THAT SUPPLIES THE CONTROLLER POWER. IT MAY BE COMPLETELY SEPARATE OR IT <br /> 32 34 36 38 40 42 44 46 48 50 52 5 56 58 60 IN1 20 e a MAY BE PART OF A STANDARD POWER SUPPLY THAT ALSO PROVIDES 24 VAC POWER TO THE <br /> 0/2-10vdc CONTROLLER. LOOK ON THE CONTROL DRAWINGS TO DETERMINE THE TYPE AND LOCATION. <br /> 12612712812911301 31 33 35 37 391411431 55 57 59 61 62 63 64 �n ti 1 <br /> 24V <br /> C P❑-R L —PANEL LINE 24 VAC r PANEL LINE 2. THE 24 VDC POWER SOURCE REFERRED TO IN SOME DETAILS COMES FROM A SEPARATE DC POWER <br /> PANEL FIELD POWER SUPPLY OR FROM A SEPARATE OUTPUT ON A STANDARD POWER SUPPLY THAT ALSO PROVIDES THE <br /> O PANEL FIELD 24 VAC POWER TO THE CONTROLLER. LOOK ON THE CONTROL DRAWING TO DETERMINE WHERE IS <br /> ODETAIL L DETAIL M DC POWER SUPPLY COMES FROM. <br /> 2 WIRE 0/2-10V CONTROL 2 POS VALVE/DAMPER ACTUATOR- RELAY IN FIELD <br /> 3. THE MAX. LENGTH OF A SIGNAL CABLE WITH 24 VAC SUPPLY IS 550 ft. (170m). THE MAX. <br /> LENGTH OF A 2 WIRE,0-10 VDC SIGNAL CABLE IS 1300 ft.(400m).THE SECONDARY SIDE OF <br /> THE TRANSFORMER MUST NOT BE CONNECTED TO EARTH GROUND. <br /> 1 1 2 1 3 4 5 6 7 B 9 10 11 12 13 14 15 1417 18 19 20 21 22 23 24 25 <br /> 4. EACH CPO-RL AND CPO-RS CONTROLLER REQUIRE PROPERLY SIZED TRANSFORMER WIRE TO MAIN <br /> 24 VAC POWER INPUT.TRANSFORMER SHOULD BE SIZED SO THAT SUFFICIENT VA CAN SUSTAIN <br /> OPERATING ALL OUTPUT TO THE FIELD DEVICE. <br /> COMFORTPOINT CPO-R CONTROLLER SPECIFIC DETAIL NOTES... <br /> DETAIL B: <br /> ONLY WIRE NTC 10/20K TEMPERATURE SENSOR SIGNAL TO UI1 TO UI6. <br /> 000 DETAIL H AND J: <br /> CONNECT A JUMPER FROM THE COMMON SIDE OF THE 24 VAC AUX POWER <br /> TRANSFORMER TO ANY OF THE COMMON TERMINALS WHEN USING 3 WIRE DEVICES <br /> oo &D( THAT ARE POWERED BY THE AUX POWER TRANSFORMER. <br /> DETAILS F AND G: <br /> RELAY OUTPUTS REQUIRED EXTERNAL 24VAC POWER. <br /> 20 21 22 TRIAC OUTPUTS ARE TRIAC OUTPUTS RATED FOR 24VAC,30mA MIN,500mA MAX. <br /> 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 DETAILS H AND I: <br /> ACTUATOR TERMINAL DESIGNATIONS WILL VARY.SEE CONTROL DRAWINGS FOR <br /> TERMINAL NUMBERS OR WIRE COLORS. <br /> C P❑—R S SIZE TRANSFORMER SO THAT TERMINAL 3/4 HAVE SUFFICIENT VA FOR OPERATING <br /> O ALL FIELD DEVICES <br /> O DETAIL K: <br /> MOUNT THE VERIS STATUS SENSOR ON ONE PHASE OF THE STARTER WIRING GOING <br /> TO THE MOTOR BEING MONITORED. <br /> DETAIL L: <br /> IF SHIELDED WIRE IS USED, EARTH SHIELD AT ONE END ONLY. <br /> 1 1 2 1 1 3 4 11 5 1 6 7 1 8 1 9 1 10111213141516171819 <br /> F— <br /> (s)Bm BBmmBmBm BmmB NOTES <br /> O 1.REFER TO DEVICE INSTALLATION INSTRUCTIONS FOR <br /> F <br /> COMPLETE WIRING INFORMATION. <br /> 2.SOME DETAILS ABOVE MAY NOT BE USED IN THIS <br /> SET OF CONTROL DRAWINGS. <br /> m Rew9ION BY AW4mrFD DUE m REASON IS AIWAIND WE AccTYTABILITY sa' „zsz4 ATE �""` CPO-RL5 WIRING DETAILS CURONT FA)UM g"e0L WE 11.25.24 <br /> 40-023 HBL EXPANSION POS 4,5,6 AHU-6L USB-027992 HWL VS 11.25.24 1185 DFSCI!'� <br /> ,BY TM 11.25.24 BNB E901-27 <br /> AvvRorm e�' DEPT. oni[ SB alvar- 11z5z4 <br /> 1V�J— 1M 1 1.=4 BUILDING 40-023 <br /> JOB No. car N0. <br /> ELECTRICAL MASTER EVERET,WA Bw'"' 40-023-ED01-27 <br />