REINFORCING STEEL: <br />REINFORCING STEEL SHALL CONFORM TO A5TM AG 15 <br />INCLUDING 51 , GRADE GO, FOR DEFORMED BAR5. <br />BARS IN BEAMS AND 5LAB5 SHALL BE SUPPORTED ON WELL -CURED <br />CONCRETE BLOCKS OR APPROVED METAL CHAIRS, AS SPECIFIED RY <br />THE CR51 MANUAL OF THE STANDARD PRACTICE, M5P-1 . <br />LAP ALL REINFORCING BARS AT SPLICES 3G DIAMETERS WITH A <br />MINIMUM LAP OF 1 8" UNLESS NOTED OTHERWISE. <br />REINFORCING 5IELL SHALL HAVE PROT CTION AS FO I OW5• <br />WALL THICKNESS HORIZ. 5AR5 VERT. BARS LOCATION <br />8" #4 @ 1 2" O.C. #4 @ I G" O.C. C. LINE OF WALL <br />- PROVIDE ONE #5 FOR 51NGLE-LAYER REINFORCING 4'-O" LONG, DIAGONALY <br />AT EACH CORNER OF OPENINGS. <br />- SLAB 5AR5 SHALL BE HOOKED INTO WALLS, OR HOOKED DOWELS SHALL BE <br />PROVIDED TO MATCH SLABS REINFORCING. <br />- PROVIDE TWO #4, 4'-0" LONG DIAGONALLY AT EACH RE-ENTRANT CORNER <br />IN 5LABS. <br />- PROVIDE HOOKED DOWELS FROM FOOTING TO MATCH VERTICAL WALL <br />REINFORCING. <br />CONCRETE A F550RI S- <br />1 . EXPANSION BOLTS SHALL BE 51MP5ON 5TRONGBOLT. <br />2. PERMANENTLY EXPOSED EMBEDED PLATES AND ANGLES SHALL <br />BE HOT -DIPPED GALVANIZED AFTER FABRICATION, <br />UNLESS NOTED OTHERWISE. <br />SAWN I UMF3FR- <br />5AWN LUMBER SHALL CONFORM TO WEST COAST LUMBER <br />INSPECTION BUREAU OR WESTERN WOOD PRODUCTS <br />ASSOCIATION GRADING RULES. <br />2" TO 4" THICK <br />HEMFIR-LARCH NO.2 300 <br />DOUGLAS FIR -LARCH NO.2 1 350 <br />P05TS <br />DOUGLAS FIR -LARCH NO.2 1200 <br />ALL LUMBER IN CONTACT WITH CONCRETE OR <br />CMU SHALL BE PRESSURE TREATED UNLESS AN <br />APPROVED BARRIER 15 PROVIDED. <br />FRAMING ACCESSORIES AND STRUCTURAL <br />FASTENERS SHALL BE MANUFACTURED BY 51MP50N <br />OR (APPROVED EQUAL) AND OF THE SIZE AND <br />TYPE SHOWN ON THE DRAWINGS. <br />HANGERS NOT SHOWN SHALL BE 5IMP50N HU OF <br />SIZE RECOMMENDED FOR MEMBER AND LOAD. <br />ALL CONNECTORS AND FASTENERS IN CONTACT WITH <br />PRESSURE TREATED LUMBER SHALL BE HOT -DIPPED <br />GALVANIZED OR HAVE OTHER APPROVED RESISTANCE <br />TO CORROSION PER R3 19.3. <br />ALL FRAMING NAILS SHALL BE COMMON NAILS AND <br />SHALL BE OF THE 51ZE AND NUMBER INDICATED ON <br />THE DRAWINGS. <br />NAILING NOT SHOWN SHALL BE AS INDICATED ON <br />THE INTERNATIONAL BUILDING CODE TABLE RG02.3(1). <br />BOLTS AND LAG SCREWS SHALL CONFORM TO <br />AN51/A5ME STANDARD B 1 (5.2. 1- 195 1. <br />ALL BOLTS AND LAG SCREWS SHALL BE INSTALLED WITH <br />STANDARD CUT WASHERS, UNLESS NOTED OTHERWISE. <br />NOTCHING OF JOISTS AND STUDS SHALL CONFORM TO <br />THE INTERNATIONAL BUILDING CODE RG02.G FIGURES, <br />RGO 1.30) AND RG02.G(I ). <br />GENE RAL STRUCTURAL NOTES <br />CONFORM TO 2018 INTERNATIONAL <br />PE51DENTIAL CODE (IRC), AS AMENDED BY <br />THE STATE OF WASHINGTON. <br />TFMPERARY CONDITIONS, <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR <br />STRUCTURAL STABILITY DURING CONSTRUCTION. <br />THE STRUCTURAL SHOWN ON THE DRAWINGS HAS <br />BEEN DESIGNED FOR STABILITY UNDER THE FINAL <br />CONSTRUCTION ONLY. <br />D 51 GN CRIT RIA• <br />DESIGN WAS BASED ON THE STRENGTH AND <br />DEFLECTION CRITERIA OF THE <br />2018 INTERNATIONAL BUILDING CODE. <br />IN ADDITION TO THE DEAD LOADS, THE FOLLOWING <br />ALLOWABLE LOADS WERE USED FOR DESIGN. <br />I ROOF 25 PSF SNOW LOAD <br />2 FLOORS 40 PSF LIVE LOAD <br />3 ALLOWABLE 501L BEARING 1 500 PSF <br />4 WIND - GUST EXPOSURE C 80 MPH 3 SECOND <br />5 ASSUMED 501L BEARING 2000 PSF <br />INSP .TION: <br />SPECIAL INSPECTION BY AN APPROVED SPECIAL <br />INSPECTOR FOR EPDXY BOLT PLACEMENT AND <br />501L BEARING SURFACES <br />.ON <br />I . CONCRETE WORK SHALL CONFORM TO CHAPTER 10 OF THE <br />INTERNATIONAL BUILDING CODE. CONCRETE STRENGTHS SHALL <br />BE VERIFIED BY STANDARD 28-DAY CYLINDER TEST PER <br />A5TM C39 AND SHALL BE AS FOLLOWS. <br />AB OS 1T WAT R-( MENT RATIQ BY WEIGHT <br />F' C (PSI) NON AIR -ENTRAINED -AIR ENTRAINED <br />COMPRESSIVE STRENGTH USE: ALL USES (UNO) <br />2. 2500 P51 0.58 OAG <br />3. A WATER -REDUCED ADMIXURE CONFORMING TO <br />C494, USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATION, SHALL BE INCORPORATED IN CONCRETE DESIGN. <br />MIXES: <br />A HIGH -RANGE WATER -REDUCING (HRWR) ADMIXTURE <br />CONFORMING TO ASTM C9494, TYPE F. <br />OR TYPE G MAY BE USED IN CONCRETE MIXES FOR <br />EXTERIOR HORIZONTAL SURFACES EXPOSED TO WEATHER. <br />THE AMOUNT OF ENTRAINED AIR SHALL BE 5 1 BY VOLUME. <br />4. PROVIDE 3/4" CHAMFERS ON ALL EXPOSED CONCRETE EDGE5 <br />UNLE55 NOTED OTHERWISE. <br />CARBON MONOXIDE ARM NOTES: <br />2015 IRG R315.2 WHERE REQUIRED <br />CARBON MONOXIDE ALARMS SHALL BE PROVIDED IN <br />ACCORDANCE WITH SECTIONS R315.2.1 AND R315.2.2. <br />2016 IRG R315.2.1 NEW CONSTRUCTION <br />FOR NEW CONSTRUCTION, AN APPROVED CARBON <br />MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH <br />SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF <br />THE BEDROOMS IN DWELLING UNITS AND ON EACH LEVEL <br />OF THE DWELLING IN ACCORDANCE WITH THE <br />MANUFAGTURER'5 RECOMMENDATION. <br />2018 IRG R315.2.2 ALTERATIONS, REPAIRS, AND ADDITIONS <br />EXISTING DWELLINGS SHALL BE EQUIPPED WITH CARBON <br />MONOXIDE ALARMS IN ACCORDANCE WITH SECTION <br />R515.2.1. AN INSPECTION WILL OCCUR WHERE ALTERATIONS, <br />REPAIRS, OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE <br />ONE OR MORE 5LEEFING ROOMS ARE ADDED OR CREATED. <br />EXCEPTIONS: <br />1.WORK INVOLVING ONLY THE EXTERIOR 5URFAGE5 OF ONELLIN675, <br />SUCH AS THE REPLACEMENT OF ROOFING OR SIDING, OR THE <br />ADDITION OR REPLACEMENT OF WINDOW5 OR DOORS, OR <br />THE ADDITION OF A PORCH OR DECK, 15 EXEMPT FROM THE <br />INSPECTION REQUIREMENT5 OF THI5 SECTION. <br />2.IN5TALLATION, ALTERATION OR REPAIRS OF NONFUEL <br />BURNING PLUMBING OR MECHANICAL SYSTEMS OR <br />ELECTRICAL SYSTEMS ARE EXEMPT FROM THE INSPECTION <br />REQUIREMENT5 OF THI5 SECTION. <br />3.0WNER-OCCUPIED 51N61-E-FAMILY RESIDENCES LEGALLY <br />OCCUPIED BEFORE JULY 26, 2009. RCN 19.27.530(2)(B). <br />SMOKE ALARM NOTES <br />R314.4 INTERCONNECTION <br />WHERE MORE THAN ONE SMOKE ALARM 15 REQUIRED TO <br />BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT IN <br />ACCORDANCE WITH SECTION R314.3, THE ALARM <br />DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER <br />THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF <br />THE ALARMS IN THE INDIVIDUAL DWELLING UNIT. WHERE AN <br />ACCESSORY DWELLING UNIT 15 CREATED WITHIN AN <br />EXISTING DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN <br />THE ACCESSORY DWELLING UNIT AND THE PRIMARY <br />DWELLING UNIT, SHALL BE INTERCONNECTED IN SUCH A <br />MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE <br />ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT AND THE <br />ACCESSORY DWELLING UNIT. PHYSICAL INTERCONNECTION <br />OF SMOKE ALARMS SHALL NOT BE REQUIRED WHERE LISTED <br />WIRELESS ALARMS ARE INSTALLED AND ALL ALARMS SOUND <br />UPON ACTIVATION OF ONE ALARM. <br />EXCEPTION: <br />SMOKE ALARMS AND ALARMS INSTALLED TO SATISFY <br />SECTION R314.4.1 SHALL NOT BE REQUIRED TO BE <br />INTERCONNECTED TO EXISTING SMOKE ALARMS WHERE <br />SUCH EXISTING SMOKE ALARMS ARE NOT INTERCONNECTED <br />OR WHERE SUCH NEW SMOKE ALARM OR ALARM 15 NOT <br />CAPABLE OF BEING INTERCONNECTED TO THE EXISTING <br />SMOKE ALARMS. <br />2018 YVA5HINGTON STATE RE51DENTIAL CODE <br />PRE5CRIPTIVE ENERGY CODE REQUIREMENT5: <br />Heating Option 4 Marine Zone <br />Ductless Heat pump 0.5 <br />Energy Options: Credits Item <br />1.3 0.5 Efficient building envelope <br />Vertical glazing = U 0.28 with reduced conductivity by 5% <br />R-42 for ceilings below a vented attic. <br />R-35 floor insulation. <br />2.2 1.0 Air leakage control & efficient ventilation <br />Whole house fan as per IRG Section 403.5 and IMG Section M-1501.3 <br />House Air Leakage Test to proof Max 2.0 air changes per hour at 50 pascals. <br />Reduce the tested air leakage to 0.25 cfm/sf max. at 50 pascals. <br />Heat recovery ventilation system with minimum sensible heat recovery <br />efficiency of 0.65 <br />3.4 1.5 High Efficiency HVAG <br />Ductless mini slit heat pump system with a minmum H5PF OF 10.0 providing heat to <br />the largest zone of the dwelling unit. Electric wall heaters for upper floor spaces. <br />5.5 2.0 Efficient Water Heating <br />Electric heat pump water heaters meeting standards of Tier III of NEEA's <br />advanced water heating specification. or <br />for R-2 Occupancy, electric heat pump water heaters) meeting standards of <br />Tier III of NEEA's advanced water heating specification shall supply domestic hot water <br />to all dwelling units. <br />If one water heater is serving more than one unit, all hot water supply and recirculation <br />piping shall be insulated with a minimum of R-8 pipe insulation. <br />1•1 0.5 Appliance Package <br />Use all Energy Star Appliances <br />Ventless dryer with GEF rating of 5.2 <br />Total Credits Claimed 6.0 <br />EXHAUST FAN RATES: <br />BATHROOMS -TOILET ROOMS <br />INTERMITTENT 50 GFM - CONTINUOUS 20 GFM <br />EXHAUST OPENIN65: <br />AIR EXHAUST OPENINGS SHALL TERMINATE AS FOLLOW5: <br />1. NOT LE55 THAN 3 FEET FROM PROPERTY LINES. <br />2. NOT LE55 THAN 3 FEET FROM GRAVITY AIR INTAKE <br />OPENINGS, OPERABLE WINDOW5 AND DOORS. <br />3. NOT LE55 THAN 10 FEET FROM MECHANICAL AIR INTAKE <br />OPENINGS EXCEPT WHERE EITHER OF THE FOLLOWING APPLY: <br />4. THE EXHAUST OPENING 15 LOCATED NOT LESS THAN 3 <br />FEET ABOVE THE AIR INTAKE OPENING. <br />5. THE EXHAUST OPENING 15 PART OF A FAGTORY-BUILT <br />INTAKE/EXHAUST COMBINATION TERMINATION FITTING <br />INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S <br />IN5TRUGTION5, AND THE EXHAUST AIR 15 DRAWN FROM A <br />LIVING SPACE. <br />6. OPENINGS SHALL COMPLY WITH SEGTION5 R303.5.2 AND R303.6. <br />HEATING TYPE AND EFFIGIENGY RATING: <br />HEATING SHALL BE DUGTLE55 MINI -SPLIT HEAT PUMP WITH <br />A H5PF OF 10.0, LOCATED OUTSIDE USING AIR 5OURGE WITH <br />ZONAL CONTROL FOR THE MAIN FLOOR & ELECTRIC WALL <br />HEATERS FOR UPPER BEDROOMS & BONUS ROOM. <br />FOR R-2 OCCUPANCIES, OPTIONAL COMPLIANCE BASED ON <br />SECTION R402.4.1.2: REDUCE THE TESTED AIR LEAKAGE TO <br />0.25 GFM/5F MAXIMUM AT 50 PASCALS. <br />WATER HEATER TYPE AND EFFIGIENGY RATING: <br />WATER HEATER SHALL BE ELEGTRIG HEAT PUMP MEETING THE <br />5TANDARD5 FOR TIER III OF NEFA'S ADVANCED WATER HEATING <br />5PEGIFIGATION5, HAVING A MINIMUM UEF OF 2A AND UTILIZING A <br />SPLIT 5Y5TEM CONFIGURATION WITH THE AIR TO REFRIGERANT <br />HEAT EXCHANGER TO BE LOCATED IN OUTDOOR AIR. <br />HOT WATER SUPPLY AND REGIRGULATION PIPES SHALL BE <br />INSULATED WITH R-8 MINIMUM PIPE INSULATION. <br />WHOLE HOUSE FAN: <br />ALL WHOLE HOUSE VENTILATION REQUIREMENT5 AS DETERMINED BY <br />SECTION M1501.3 OF THE INTERNATIONAL RESIDENTIAL GODE OR <br />SECTION 403.8 OF THE INTERNATIONAL MECHANICAL CODE SHALL <br />BE MET WITH A HEAT REGOVERY VENTILATION SYSTEM WITH MINIMUM <br />5EN51BLE HEAT RECOVERY EFFIGIENGY OF 0.65. <br />ALL NINDOW5 SHALL HAVE A MAX. 'U' VALUE OF 0.25 <br />D EXTERIOR ELEYATIQN <br />NUMBERILABEL <br />GTY <br />5 Z= <br />R/G <br />S R TON <br />W01 <br />6040L5 <br />1 <br />6040L5 <br />'13%49" <br />LEFT 51-I1)ING <br />Vg52 <br />5040FX <br />q <br />3040FX <br />31"X49" <br />FIXED 61LA55 <br />1N04 <br />5040FX <br />2 <br />5040FX <br />61"X49" <br />FIXED GLA55 <br />YV05 <br />504OL5 <br />5 <br />5940L5 <br />61"X4q" <br />LEFT SLIDING <br />W06 <br />5040R5 <br />5 <br />5040R5 <br />61"X41" <br />RIGHTSLIDING <br />EE- <br />W07 <br />404G1_5 <br />2 <br />404.01-5 <br />4q"X49" <br />LEFT SLIDING <br />ma <br />404OR5 <br />1 <br />404OR5 <br />4q"X4q" <br />RIGHT 5LIDING <br />Ell <br />1N0q <br />30405H <br />2 <br />30405H <br />37'X49" <br />51NGLE HUNG <br />ALL E <br />,,S V` <br />9 <br />5 <br />^pxH <br />T' <br />FIXED GLASS <br />M 5ILL <br />HEIG <br />T OF <br />42". <br />GLEAR <br />TO 5 E H I <br />E N I N 5 <br />- IF <br />OF E <br />R.- I-.' - <br />5 R <br />i I - <br />55 WI 1 q <br />r- I q,:; ; <br />DO <br />- - ± <br />- - - - I <br />2018 WASHINGTON STATE RESIDENTIAL CODE <br />PRESGRIPTIVE ENERGY GODE REQUIREMENT5: <br />Heatin® Option 4 Marine_ Zone 4 <br />Ductless Heat pump 0.5 <br />Energy Options: credits Item <br />1.3 0.5 Efficient building envelope <br />vertical glazing = U 0.25 with reduced conductivity by 5% <br />R-42 for ceilings below a vented attic. <br />R-38 floor insulation. <br />2.2 1.0 Air leakage control & efficient ventilation <br />Whole house fan as per IRG Section 403.8 and IMG Section M-1507.3 <br />House Air Leakage Test to proof Max 2.0 air changes per hour at 50 pascals. <br />Reduce the tested air leakage to 0.25 cfm/sf max. at 50 pascals. <br />Heat recovery ventilation system with minimum sensible heat recovery <br />efficiency of 0.65 <br />3.4 1.5 High Efficiency HVAG <br />Ductless mini slit heat pump system with a minimum H5PF OF 10.0 <br />providing heat to the largest zone of the dwelling unit. <br />Electric wall heaters for upper floor spaces. <br />5.5 2.0 Efficient Water Heating <br />Electric heat pump water heaters meeting standards of Tier III of NEEA's <br />advanced water heating specification. or <br />for R-2 Occupancy, electric heat pump water heaters) meeting standards of <br />Tier III of NEEA's advanced water heating specification shall supply domestic <br />hot water to all dwelling units. <br />If one water heater is serving more than one unit, all hot water supply and <br />recirculation piping shall be insulated with a minimum of R-8 pipe insulation. <br />7.1 0.5 Appliance Package <br />Use all Energy Star Appliances <br />Ventless dryer with GEF rating of 5.2 <br />Total Credits Claimed 6.0 <br />L <br />,O <br />V_ <br />Cn <br />rJ <br />O <br />oao <br />(425) 268-1701 <br />dedprodesign@gmail.com <br />"REVISIONS <br />VJ <br />LU <br />Q <br />LU <br />T <br />.v <br />V J <br />Z <br />rt-U <br />LU <br />7-U <br />LU <br />V <br />O <br />LU1J <br />, n <br />o <br />v <br />N <br />U <br />LU O <br />D <br />a- <br />< <br />PAGE <br />I of <br />2/25/2024 <br />