FRAMING LUMBER <br />BUILDING CODE <br />2021 INTERNATIONAL BUILDING CODE <br />FLOOR LOAD <br />DEAD LOAD 12 psf <br />LIVE LOAD: 40 psf <br />ROOF LOAD <br />DEAD LOAD: <br />FLAT ROOF SNOW LOAD: <br />SNOW EXPOSURE FACTOR (Ce): <br />SNOW LOAD IMPORTANCE FACTOR (Is): <br />THERMAL FACTOR (Ct): <br />SLOPE FACTOR (Cs): <br />WIND DESIGN DATA <br />1. BASIC WIND SPEED: <br />2. ALLOWABLE STRESS DESIGN WIND SPEED: <br />2. WIND IMPORTANCE FACTOR (Iw): <br />BUILDING CATEGORY: <br />3. WIND EXPOSURE: <br />4. Kzt = <br />5. INTERNAL PRESSURE COEFFICIENT: <br />6. APPLICABLE WIND PRESSURE FOR <br />COMPONENTS AND CLADDING: <br />SEISMIC DESIGN DATA <br />1. SEISMIC IMPORTANCE FACTOR: <br />SEISMIC USE GROUP: <br />2. SPECTRAL RESPONSE ACCELERATION (Ss): <br />3. SITE CLASS: <br />4. SPECTRAL RESPONSE COEFFICIENTS (SDS) <br />5. SEISMIC DESIGN CATEGORY: <br />6. BASIC SEISMIC -FORCE -RESISTING SYSTEM <br />7. DESIGN BASE SHEAR: <br />8. SEISMIC RESPONSE COEFFICIENT (Cs): <br />9. RESPONSE MODIFICATION FACTOR (R): <br />10. ANALYSIS PROCEDURE USED: <br />RAIN DESIGN DATA <br />15 psf <br />25 psf <br />1.1 <br />1.0 <br />1.1 <br />NA <br />110 MPH <br />86 MPH <br />1.0 <br />IB <br />1.00 <br />NA <br />NA <br />1.0 <br />131.6% G <br />D (ASSUMED) <br />105.3%G <br />D <br />SHEARWALLS <br />SEE CALCULATIONS <br />0.162 <br />6.5 <br />EQUIVALENT LATERAL FORCE PROCEDURE <br />1. RAIN INTENSITY: 1 IN./HOUR <br />FOUNDATIONS <br />1. THE FOUNDATION DESIGN IS BASED ON THE RECOMMENDATION IN THE INTERNATIONAL <br />BUILDING CODE TABLE 1806.2. FOUNDATION WORK SHALL BE PERFORMED IN ACCORDANCE WITH <br />CHAPTER 18 OF THIS CODE. <br />2. THE FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES: <br />ALLOW. SOIL BEARING = 1500 PSF <br />SOIL FRICTION = 25 <br />EQUIV. FLUID PRESSURES: <br />*ACTIVE PRESSURE = 35 PCF <br />PASSIVE PRESSURE = 150 PCF <br />*(WALLS RESTRAINED AGAINST ROTATION SHALL BE DESIGNED FOR AN EQUIV. FLUID <br />PRESSURE OF 55 PCF). <br />3. ALL FOOTINGS SHALL BE FOUNDED AT LEAST 18" BELOW THE UNDISTURBED GROUND <br />SURFACE OR TO FROST DEPTH. ALL FOOTINGS SHALL BE FOUNDED ON COMPACTED FILL OR <br />UNDISTURBED NATURAL GRADE UNLESS OTHERWISE NOTED. <br />4. COMPACTION: MATERIAL FOR FILLING AND BACKFILLING SHALL CONSIST OF THE EXCAVATED <br />MATERIAL AND/OR IMPORTED BORROW AND SHALL BE FREE OF ORGANIC MATTER, TRASH, <br />LUMBER, OR OTHER DEBRIS. ALL WALLS SHALL BE ADEQUATELY BRACED PRIOR TO <br />BACKFILLING. FILL AND BACKFILL SHALL BE DEPOSITED IN LAYERS NOT TO EXCEED 8 INCHES <br />THICK, PROPERLY MOISTENED TO APPROXIMATE OPTIMUM REQUIREMENTS AND THOROUGHLY <br />ROLLED OR COMPACTED WITH APPROVED EQUIPMENT IN SUCH A MANNER AND EXTENT AS TO <br />PRODUCE A RELATIVE COMPACTION OF 90% OF MAXIMUM POSSIBLE DENSITY AS DETERMINED <br />BY ASTM D1557. HAND TAMPERS SHALL WEIGH AT LEAST 50 POUNDS EACH AND SHALL <br />HAVE A FACE AREA NOT IN EXCESS OF 64 SQUARE INCHES. HAND TAMPERS MAY BE <br />OPERATED EITHER MANUALLY OR MECHANICALLY AND SHALL BE USED WHERE LARGER POWER <br />DRIVEN COMPACTION EQUIPMENT CANNOT BE USED. FILL OVER 12" DEEP SHALL COMPLY WITH <br />A GEOTECHNICAL REPORT. <br />REINFORCING STEEL <br />1. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 (fy = 60 KSI) FOR <br />BAR SIZES NO. 5 & LARGER, GRADE 40 (fy = 40 KSI) FOR NO. 3 AND NO. 4 BARS. <br />2. ALL REINFORCING STEEL SHALL BE LAPPED AS NOTED ON THE PLANS. WHERE LAP OR <br />SPLICE LOCATIONS ARE NOT SPECIFICALLY INDICATED ON THE CONSTRUCTION DOCUMENTS, <br />LAPS AND/OR SPLICES SHALL BE 42 BAR DIA AND BE WELL STAGGERED. <br />3. COMPLETE REINFORCING PLACEMENT DRAWINGS PREPARED IN ACCORDANCE WITH ACI 315 <br />SHALL BE REVIEWED BY THE ENGINEER AND AVAILABLE ON THE JOB SITE PRIOR TO THE <br />PLACING OF CONCRETE. <br />4. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A82 AND A185 AND SHALL BE 6x6 <br />W2.1 /W2.1 UNLESS OTHERWISE NOTED. LAP REINFORCEMENT 6" MINIMUM. <br />5. ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS SHALL BE SECURELY TIED IN PLACE <br />BEFORE CONCRETE IS POURED. SLAB ON GRADE REINFORCEMENT SHALL BE PLACED AT <br />MID -DEPTH OF SLAB AND SHALL BE HELD SECURELY IN PLACE WITH MECHANICAL DEVICES <br />DURING PLACING OF THE CONCRETE. <br />CONCRETE <br />1. ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR WEIGHT HARD ROCK TYPE <br />(150 PCF) AGGREGATES SHALL CONFORM TO ASTM C33 WITH PROVEN SHRINKAGE <br />CHARACTERISTICS OF LESS THAN 0.05%. <br />2. CONCRETE COMPRESSIVE DESIGN STRENGTHS AT 28 DAYS (F'c) SHALL BE: <br />CONCRETE EXPOSURE & COMPRESSIVE DESIGN STRENGTHS <br />DESIGNATION <br />CONDITIONS <br />EXPOSURE <br />MIN. f'c (psi) <br />CLASS <br />HEATED: SLABS, BEAMS, GIRDERS, <br />INTERIOR CONC. & <br />FO <br />2500 <br />COLUMNS, PIERS, AND BURIED FOOTINGS <br />FOOTINGS <br />FOUNDATION WALLS, UN -HEATED: SLABS, <br />FREEZING & THAWING <br />BEAMS, GIRDERS, COLUMNS, PIERS, PILE <br />CYCLES WITH LIMITED <br />F1 <br />3500 <br />CAPS, SHEAR WALLS <br />EXPOSURE TO WATER <br />3. ALL CONCRETE WITH A DESIGNATED COMPRESSIVE STRENGTH EXCEEDING 2500 PSI SHALL <br />REQUIRE SPECIAL INSPECTION BY AN INSPECTOR APPROVED BY THE BUILDING DEPARTMENT <br />AND THE ENGINEER. EXCEPTION: NO INSPECTION IS REQUIRED WHERE CONCRETE EXCEEDING <br />2500 PSI IS DESIGNATED FOR WEATHERING PURPOSES ONLY. <br />4. CEMENT SHALL CONFORM TO ASTM C150, TYPE I, CSA NORMAL. <br />5. MAXIMUM SLUMP SHALL NOT EXCEED 4 INCHES IN FLATWORK. <br />6. PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH ACI 301. <br />1. FRAMING LUMBER SHALL BE DOUGLAS FIR/LARCH NO.1 FOR POSTS, BEAMS, AND HEADERS; <br />HEM -FIR NO.2 FOR 2X AND 3X JOISTS, AND STUDS; AND HEM -FIR NO.2 FOR ALL TOP AND <br />BOTTOM PLATES (GRADES ARE TYPICAL UNLESS OTHERWISE NOTED ON PLANS). LUMBER TO BE <br />GRADE MARKED PER WCLIB SPECIFICATIONS. <br />2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD, EXPOSURE 1 SHEATHING <br />CONFORMING TO EITHER COMMERCIAL STANDARDS DOC PS 1 OR PS 2. PROVIDE MINIMUM OF <br />3/8" EDGE DISTANCE ON ALL NAILS AND A )8" EXPANSION JOINT BETWEEN ALL PANEL EDGES. <br />MINIMUM SHEATHING REQUIREMENTS ARE AS FOLLOWS: <br />ROOF SHEATHING TO BE 1%2" C-D INT-APA RATED PLYWOOD WITH EXTERIOR GLUE, P.I <br />24/16 (USE 5-PLY FOR PANELIZED ROOFS). NAIL WITH 8d NAILS AT 6" ON CENTER <br />AT PANEL EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED <br />OTHERWISE. <br />SUB <br />FLOORING TO BE 3/4" T&G C-D <br />INT-APA <br />RATED PLYWOOD WITH EXTERIOR GLUE, <br />P.I. <br />48/24. GLUE AND NAIL WITH <br />10d NAILS <br />AT 6" ON CENTER AT PANEL EDGES AND <br />12" <br />ON CENTER AT INTERMEDIATE <br />SUPPORTS <br />UNLESS NOTED OTHERWISE. <br />3. NAILING SHALL CONFORM TO TABLE 2304.10.2 OF THE INTERNATIONAL BUILDING CODE <br />UNLESS NOTED OTHERWISE. USE COMMON NAILS THROUGHOUT UNLESS NOTED OTHERWISE. <br />4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY DETAILED OR <br />APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. <br />5. USE DOUBLE JOISTS UNDER WALLS OR PARTITIONS PARALLEL TO JOISTS UNLESS <br />SPECIFICALLY NOTED OTHERWISE. USE SOLID BLOCKING UNDER PARTITIONS PERPENDICULAR TO <br />JOISTS. <br />7. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF FIVE (5) DAYS <br />AFTER PLACEMENT. ALTERNATE METHODS WILL BE APPROVED IF SATISFACTORY PERFORMANCE 6. RIM JOIST ARE 1Y4" LSL OR 2x SOLID SAWN LUMBER AS MINIMUM. <br />CAN BE ASSURED. <br />8. KEYED CONSTRUCTION JOINTS SHALL BE USED IN ALL CASES. ALL CONSTRUCTION JOINTS <br />SHALL BE THOROUGHLY CLEANED AND ALL LAITANCE SHALL BE REMOVED. ALL VERTICAL <br />JOINTS SHALL BE THOROUGHLY WETTED AND SLUSHED WITH A COAT OF NEAT CEMENT <br />IMMEDIATELY BEFORE PLACING NEW CONCRETE. <br />9. SUBMIT LOCATION OF POUR JOINTS PRIOR TO PLACEMENT. POUR JOINTS SHALL BE LOCATED <br />TO MINIMIZE EFFECTS OF SHRINKAGE AS WELL AS PLACED AT POINTS OF LOW STRESS. <br />MAXIMUM AREA OF POUR JOINTS IS 400 SF. <br />10. MINIMUM CONCRETE COVERAGE OF REINFORCING STEEL FOR FORMED WORK SHALL BE AS <br />FOLLOWS: <br />EXPOSED TO EARTH OR <br />WEATHER <br />(#5 OR <br />SMALLER): <br />1 36" <br />EXPOSED TO EARTH OR <br />WEATHER <br />(#6 OR <br />LARGER): <br />2" <br />*NOTE: CONCRETE CAST <br />AGAINST <br />GROUND <br />SHALL HAVE <br />3" MINIMUM COVERAGE <br />11. PIPES OTHER THAN ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL <br />CONCRETE EXCEPT WHERE SPECIFICALLY APPROVED. <br />12. LEAN CONCRETE SHALL BE 2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE. <br />13. CONCRETE MIXES SHALL BE PROVIDED IN ACCORDANCE WITH ACI 318. <br />14. CONCRETE EXPOSED TO SULFATES, CONCRETE WITH LOW PERMEABILITY REQUIREMENTS, <br />AND CONCRETE WITH CHLORIDE ION CONTENT REQUIRE ADDITIONAL MIX DESIGN <br />CONSIDERATIONS. IN THE EVENT OF THESE REQUIREMENTS THE ENGINEER SHALL BE NOTIFIED <br />BY THE CLIENT IN A WRITING AND DESIGN MIXES SHALL BE PROVIDED PER ACI 318. <br />CEMENT CONTENT <br />F'c (PSI) <br />LBS/CUBIC YARD (MIN.) <br />SACKS PER CUBIC YARD <br />(MIN.) <br />NOTES <br />2500 <br />470 <br />5 <br />NOTE A <br />3500 <br />564 <br />6 <br />- <br />NOTE 1: MIXES SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. NO MORE <br />THAN A 1" PLUS TOLERANCE SHALL BE ALLOWED. <br />NOTE 2: AIR ENTRAINMENT IS REQUIRED FOR ALL CONCRETE EXPOSED TO WEATHER. FOR 3/4" <br />AGGREGATE AN ENTRAINMENT OF 6% IS REQ'D. FOR X2" AGGREGATE AN AIR ENTRAINMENT OF <br />7% IS REQ'D. <br />NOTE 3: POZZOLANS ARE NOT PERMITTED IN THE MIX DESIGN UNLESS APPROVED BY THE <br />ENGINEER. <br />A) WHERE SPECIAL INSPECTION IS NOT REQUIRED UNDER SECTION 1704.4 OF THE I.B.C., <br />CONCRETE SHALL HAVE A MINIMUM CEMENT CONTENT OF 5 SACKS PER CUBIC YARD OF <br />CONCRETE. <br />B) FOR STRENGTHS ABOVE 4000 PSI, PROPORTIONS SHALL BE ESTABLISHED BY THE METHODS <br />SPECIFIED ACI 318. <br />C) DESIGN MIX (OTHER THAN AS SPECIFIED IN THIS TABLE) SHALL BE SUBMITTED TO THE <br />BUILDING OFFICIAL TWO WEEKS PRIOR TO FIRST USE. <br />GLUED -LAMINATED TIMBER <br />1. ADHESIVE SHALL BE FOR WET USE. <br />2. LAMINATIONS SHALL BE OF DOUGLAS FIR/WESTER LARCH, COMBINATION 24F-V4 FOR <br />SIMPLE SPAN BEAMS AND 24F-V8 FOR CONTINUOUS MULTIPLE SPAN AND CANTILEVERED <br />BEAMS, FABRICATED IN ACCORDANCE WITH AITC A190.1 AND ASTM D 3737. <br />3. FABRICATION SHALL BE BY A LICENSED FABRICATOR; SHOP DRAWINGS SHALL BE SUBMITTED <br />TO THE ENGINEER FOR APPROVAL PRIOR TO FABRICATION. AITC CERTIFICATES OF INSPECTION <br />ARE REQUIRED FOR ALL MEMBERS. <br />7. MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 16% FOR ALL STRUCTURAL MEMBERS. <br />8. PROVIDE 2X2 WASHERS UNDER HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING <br />ON WOOD UNLESS NOTED OTHERWISE. <br />9. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS Y16" UNLESS OTHERWISE NOTED. <br />LAG BOLT PILOT HOLES SHALL BE PRE -DRILLED TO 60% OF THE NOMINAL DIAMETER OF THE <br />LAG BOLT UNLESS OTHERWISE NOTED. <br />10. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH 5/s" MINIMUM DIAMETER <br />BOLTS SPACED AT 48" O.C. MAXIMUM SPACING (EMBED 7" MINIMUM INTO CONCRETE OR <br />MASONRY). SEE PLANS AND DETAILS FOR SPECIFIC REQUIREMENTS. <br />11. ALL FRAMING LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE <br />TREATED. (SEE NOTE 1 FOR MINIMUM GRADE INFORMATION) IN CONFORMANCE WITH AWPA U1. <br />ALL FOUNDATION BOLTS AND CONNECTORS MUST BE HEAVY GALVANIZED, OR Z-MAX COATING <br />TO PROTECT FROM CORROSION. <br />12. FIELD -CUT ENDS, NOTCHES, AND DRILLED HOLES OF PRESSURE TREATED WOOD SHALL BE <br />RETREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. PER IRC R317.1.1. <br />13. 2X4 RAFTERS EXCEPT WHERE SPECIFICALLY DETAILED SHALL NOT SUPPORT SUSPENDED <br />CEILINGS, SPRINKLERS, DROP SOFFITS, OR ANY OTHER ELEMENTS. <br />14. EXTERIOR STUD WALLS SHALL BE 2X6 @ 16" O.C.. UNLESS NOTED OTHERWISE. INTERIOR <br />STUD BEARING WALLS SHALL BE CONSTRUCTED USING 2X4 @ 16" O.C. AT UPPER TWO <br />FLOORS AND EITHER 2X6 Q 16" O.C. OR 3X4 @ 16" O.C. BELOW TOP TWO FLOORS. STUD <br />NONBEARING WALLS SHALL BE CONSTRUCTED USING 2X4 @ 24" O.C.. UNLESS NOTED <br />OTHERWISE. SEE NOTE 1 FOR LUMBER GRADES OF STUDS AND PLATES. <br />15. FRAMING ANCHORS FOR JOISTS, PURLINS AND POSTS SHALL BE SIMPSON, OR APPROVED <br />EQUAL. APPROVAL MUST BE OBTAINED IN WRITING PRIOR TO INSTALLATION. FILL ALL <br />FASTENER HOLES WITH FASTENER TYPES (NAILS, BOLTS, ETC.), SIZES, AND QUANTITIES AS <br />SPECIFIED BY THE MANUFACTURER. <br />16. ALL HEADERS SHALL BE 4X8 DF#2 UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />17. OSB OF EQUAL OR GREATER THICKNESS MAY BE SUBSTITUTED FOR PLYWOOD USED IN <br />SHEAR PANELS. <br />18. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO THESE DETAILS AND NOTES. <br />19. BLOCKING SHALL BE PROVIDED AT ALL POINTS OF BEARING TO PREVENT ROTATION OF <br />JOISTS AND BEAMS. <br />20. ALL FRAMING NAILS SHALL BE COMMON UNLESS NOTED OTHERWISE. <br />MANUFACTURED LUMBER <br />1. LAMINATED VENEER LUMBER DESIGN IS BASED ON MICROLAM LVL PRODUCTS AS SUPPLIED <br />BY TRUSS -JOIST MACMILLAN IN ACCORDANCE WITH ASTM D 5456. DESIGN PROPERTIES SHALL <br />BE: <br />Fb = 2600 PSI Fv = 285 PSI E = 2.Ox10�6 PSI <br />2. PROPOSED SUBSTITUTIONS SHALL BE SUBMITTED ALONG WITH THE APPROPRIATE ICBO <br />EVALUATION REPORTS TO THE ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION. INSTALLATION <br />OF SUBSTITUTIONS SHALL NOT PROCEED WITHOUT PRIOR WRITTEN APPROVAL OF THE <br />ENGINEER. <br />D <br />MAR 0 5 2024 <br />CITY GE EVERETT <br />Permit 6'ervices <br />> O N <br />U <br />Q N 000 <br />0 <br />W r� <br />Q <br />0'U <br />U�,ri> <br />o <br />a� <br />4+ 1 <br />U <br />::3 <br />Q <br />O >O <br />I'`) w = <br />_--' <br />n <br />z <br />a <br />o <br />> <br />� <br />> <br />> <br />Ln <br />- <br />Of <br />w <br />G <br />J <br />Q <br />U <br />J <br />U <br />m <br />N <br />N <br />I <br />W <br />~ <br />00 <br />� <br />i <br />Q <br />p <br />I <br />N <br />O <br />0 <br />z <br />o <br />x <br />LLJ <br />J <br />Lw <br />> N <br />0 60 <br />zo-) <br />LLJ O Q <br />Q U - <br />Q H- <br />z_D� <br />W <br />0rr) cj!� <br />(n O W <br />W <br />U <br />Q <br />FEB 19, 2024 <br />Drawn By: CHRIS L. <br />Checked By. CHRIS <br />Date: 02-15-2024 <br />SDA JOB NO. <br />9902 <br />STRUCTURAL <br />NOTES <br />S-1.0 <br />6. REINFORCEMENT SHALL PLACED CONTINUOUS AROUND CORNERS AND INTERSECTIONS <br />UNLESS SPECIFIED OTHERWISE. <br />4. GLULAM BEAMS EXPOSED TO WEATHER SHALL BE WOLMANIZED OR PRESSURE TREATED. <br />EXTERIOR GLULAM BEAMS SHALL BE FLASHED AT ENDS AND TOP TO REDUCE MOISTURE <br />EXPOSURE. <br />