Mr. Ermias Kau <br />eMD Design Practice <br />Plan Check Number: B2203-001, First Building Review <br />May 3, 2022 <br />4. The number and spacing of the deck stair stringers in the Framing Plan on Sheet S2.1 is not <br />dear. The joist spacing and spans should not exceed Table R302.3.1(2) considering a minimum <br />40 psf live load. Joists should be based on the net depth after notching for stairs. Additional <br />sistered framing may be required for strength and is recommended to control deflections; <br />fasteners should be specified. See Sections R106.1.1 and R301.1. <br />5. Upper Plan 2/A2.2 includes a new window opening in the south exterior wall. A header, and <br />king and jamb studs, should be specified. See Sections R306.1.1 and R602.7 <br />6. The Roof Framing Plan on Sheet S2.2 includes discontinuous shear walls supported by a beam <br />at the new addition. Multiple shear walls appear to be discontinuous and transfer holdown <br />loads through supporting beams. The beams are required to be designed for seismic loads <br />including overstrength per ASCE 7-16 Section 12.3.3.3. The design loads should include vertical <br />load effects per Section 12.4.2.2. Calculations substantiating the design should be submitted for <br />review. See IBC Sections 1604.1 and 1604.4. <br />7. Structural calculations for the shear wall holdown anchorage to the concrete foundations should <br />be submitted for review. The earthquake component of the uplift forces exceeds 20% of the <br />total uplift (i.e., the earthquake force is 100% of uplift force). The earthquake component <br />should be increased per the provisions of ACI 318-14 Section 17.2.3.4.3. The design load <br />should include the vertical seismic load effect per Section 12.4.2.2. See IBC Sections 1604.10, <br />1613.1, and 1901.2. <br />8. The Upper Level addition has a Type 2 Horizontal Irregularity per ASCE 7-16 Table 12.3-1 on <br />the north side, and a Type 4 Vertical Irregularity per ASCE 7-16 Table 12.3-2 on the north and <br />west sides. The diaphragm chords at the second floor and roof are required to be developed <br />into the main building structure to transfer lateral forces. See IBC Sections 1604.1, 1604.4, <br />1613.1, and 2306.1. The following comments should be addressed: <br />a. Chords and connections to transfer lateral forces from the addition to the main building <br />should be specified in the framing plans. <br />b. The chords should be developed in the main building diaphragms considering increased <br />loading per Section 12.3.3.4. See also AWC SDPWD-15 Sections 4.1.4 and 4.2.6. <br />9. Details for the roof overfiaming construction should be provided. The details should specify <br />interconnection of the existing and new diaphragm sheathing. See Section R106.1.1. <br />10. The connection requirements appear to be missing for the new addition Upper Floor Framing <br />Plan on Sheet S2.1. See Sections R106.1.1 and R301.1. The following comments should be <br />addressed: <br />a. A ledger connection should be included between the addition floor and the existing east <br />building wall. <br />b. Multiple beam connections to the supporting framing appear to be missing. <br />03200 Cedar Street 425.257.8810 everetteps@everettwa.gov <br />Everett, WA mm 1 425.257.889 fax ® everettwa.gov/permits <br />Pne4N5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.