My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1720 100TH ST SW 2025-11-07
>
Address Records
>
100TH ST SW
>
1720
>
1720 100TH ST SW 2025-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2025 11:55:13 AM
Creation date
10/14/2025 9:22:30 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
1720
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
194
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr, Rakeeb Khan <br /> October 26, 2022 <br /> Page 2 <br /> equipment efficiency per selected option 3.6. WSEC Table R406.3 <br /> 5. The correction is shown on page A7 under item 5. The minimum equipment efficiency is: <br /> 10HSPF. <br /> 6. See the selected energy credits on Sheet A7. The drawings should specify the minimum <br /> equipment efficiency per selected option 5.5. WSEC Table R406.3 <br /> Correction is on page A7 under item #6. Electric heat pump water heater meeting the standards for Tier III of <br /> NEEA's advanced water heating specification <br /> Structural <br /> 1. The walls at the stairway appear to be up to 18 feet in height. The wall height exceeds the <br /> prescriptive limitation of the IRC and the shear walls at the location of the stairway do not meet <br /> the shear wall aspect ratio of 3.5 per Table 4.3.4 of the Special Design Provisions for Wind and <br /> Seismic (SDPWS). Shear walls should be updated and calculations substantiating the design <br /> should be submitted for review. R106.1.1, R602.3.1 <br /> Updated calculations are provided with this response letter. The wall will be standard framed <br /> with a wind beam to span the gap in the floor diaphragm. <br /> 2. Continuing with the previous comment, the walls at the stairway should be balloon framed <br /> from <br /> floor to roof to prevent a hinge at the 2nd floor level or provide a wind beam to resist horizontal <br /> wind loads acting on the wall. Submit calculations substantiating the design for review. <br /> R106.1.1, R602.3.1 <br /> Wind beam added <br /> 3. It appears that some of the glulam beams are exposed to weather. Plans should specify the <br /> exposed glulam beams to be pressure treated with preservative or manufactured from naturally <br /> durable or preservative-treated wood. R317.1.5 <br /> Note added for pressure treatment of glulams for above grade, exterior application <br /> 4. Details for the deck guardrail should be provided. The guards should comply with IRC Section <br /> 11/09/22 11:01 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.