14. Painted Heads-Where sprinklers or cover plates on concealed sprinklers have ❑ ❑ ❑ <br /> been painted by other than the sprinkler manufacturer,they shall be replaced. <br /> 15. Listings- Escutcheons used with recessed, flush-type, or concealed sprinklers shall ❑ ❑ ❑ <br /> be part of a listed sprinkler assembly and be metallic or shall be listed for use <br /> around a sprinkler. No caulking or glue shall be used to seal penetrations or to <br /> affix the components of a recessed escutcheon or concealed cover plate. <br /> 16. Spare Sprinkler Cabinet-Spare Sprinkler cabinet, sprinkler wrench, and spare ❑ ❑ ❑ <br /> sprinklers shall be provided. The stock of spare sprinklers shall include all types <br /> and ratings installed and shall be as follows: <br /> • Facilities having under 300 sprinklers—no fewer than six sprinklers <br /> • Facilities having 300 to 1000 sprinklers—no fewer than 12 sprinklers <br /> • Facilities having over 1000 sprinklers—no fewer than 24 sprinklers <br /> (Where dry sprinklers of different lengths are installed, spare dry sprinklers shall <br /> not be required, provided that a means of returning the system to service is <br /> furnished.) <br /> 17. Sprinkler List-A list of the sprinklers installed in the property shall be posted in ❑ ❑ ❑ <br /> the spare sprinkler cabinet.The list shall include the following: <br /> • Sprinkler Identification Number(SIN) if equipped; or the manufacturer, <br /> model, orifice, deflector type,thermal sensitivity, and pressure rating <br /> • General description <br /> • Quantity of each type to be contained in the cabinet <br /> • Issue or revision date of the list <br /> 18. Sprinkler Guards-Sprinklers subject to mechanical injury shall be protected with ❑ ❑ ❑ <br /> listed guards. <br /> Fire Department Connection (FDC): <br /> PASS FAIL N/A <br /> 19. Assessable/Orientated -The FDC shall be assessable and arranged/orientated so ❑ ❑ ❑ <br /> that a hose line can be attached to the inlets without interference. <br /> 20. Clear Space-A clear working space not less than 36 inches in width, 36 inches in ❑ ❑ ❑ <br /> depth and 78 inches in height shall be provided. <br /> 21. Knox Caps- Fire department connections shall be equipped with approved Knox ❑ ❑ ❑ <br /> plugs/caps. <br /> 22. Signs-Verify that a sign complying with the following has been provided: ❑ ❑ ❑ <br /> • Metal sign with raised letters not less than 1 inch in sized. <br /> • Signs shall read AUTOMATIC SPRINKLERS or STANDPIPES or TEST <br /> CONNECTION or combination thereof as applicable. <br /> • Where the FDC does not serve the entire building, a sign shall be provided <br /> indicating the portions of the building served. (Address, Location, Zone...) <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-6 4.13.2020 I Page 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.