VP-2B: Dress panel, required when CA-2 chassis is installed in the <br /> top two cabinet rows. <br /> DPA-1A4: Dress panel,used with the CA-1 chassis when the CMIC- <br /> 1 is not used. Provides mounting options on right two bays for two <br /> ACS annunciators,or for blank plates. See DN-7045. <br /> BP-CA2: Blank plate for CA-2 chassis. <br /> SEISKIT-CAB: Seismic mounting kit. Required for seismic-certified <br /> applications with NFS2-640 and other equipment mounted in CAB-4 <br /> Series Enclosures. Includes battery bracket for two 26 AH batteries. <br /> SEISKIT-LBB:Seismic kit for the NFS-LBB.Includes battery bracket <br /> for two 55 AH batteries. <br /> BACKBOXES <br /> NOTE:"C"suffix indicates ULC-Listed model. <br /> ABF-1 B(C)Annunciator Flush Box. <br /> ABF-1 DB(C)Annunciator Flush Box with Door. <br /> ABF-213 Annunciator Flush Box <br /> ABF-2DB/C Annunciator Flush Box with Door <br /> ABF-413 Annunciator Flush Box <br /> ABS-1TB(C)Annunciator Surface Box <br /> ABS-1 B(C)Annunciator Surface Box <br /> ABS-213 Annunciator Surface Box <br /> ABS-213(C)Annunciator Surface Box <br /> ABS-413(C)Annunciator Surface Box <br /> BB-UZC: Backbox for housing the UZC-256 in applications where <br /> the UZC-256 will not fit in panel enclosure. Black; for red, order BB- <br /> UZC-R. <br /> OTHER OPTIONS <br /> CGW-MB: CLSS Gateway for Internet/cloud-based communication <br /> between the FACP and peripheral devices. See HON-62034. <br /> HON-CGW-MBB: CLSS Gateway, pre-installed in a cabinet. See <br /> HON-62034. <br /> 411: Slave digital alarm communicator. See DN-6619. <br /> 411 UDAC: Digital alarm communicator.See DN-6746. <br /> IPDACT-2/21LID,IPDACT Internet Monitoring Module:Connects to <br /> primary and secondary DACT telephone output ports for internet <br /> communications over customer-provided Ethernet connection. <br /> Requires compatible Teldat VisorALARM Central Station Receiver. <br /> Can use DHCP or static IP. See DN-60408. <br /> IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting <br /> an IPDACT-2/2UD onto the panel chassis or CHS-4 series chassis. <br /> Use IPENC for external mounting applications. <br /> IPSPLT: Y-adapter option allow connection of both panel dialer out- <br /> puts to one IPDACT-2/2UD cable input. <br /> IPENC: External enclosure for IPDACT, includes IPBRKT mounting <br /> bracket; Red. For Black order IPENC-B. <br /> HWF2V-COM: LTE Digital Cellular Fire Alarm Communicator and <br /> Internet Panel, Verizon LTE / IP. Provides selectable configurable <br /> paths:cellular only, IP only, or IP primary with cellular backup.Con- <br /> nects to the primary and secondary ports of a DACT.See DH-62010. <br /> (For Canadian applications order IPGSM-4GC. See DH-60771.) <br /> HWHA-COM: LTE Digital Cellular Fire Alarm Communicator and <br /> Internet Panel, AT&T LTE / IP. Provides selectable configurable <br /> paths:cellular only, IP only, or IP primary with cellular backup.Con- <br /> nects to the primary and secondary ports of a DACT. (For Canadian <br /> applications order IPGSM-4GC. See DH-60771.) <br /> NOTE: For other options including compatibility with retrofit equipment, <br /> refer to the panel's installation manual, the SLC manual,and the Device <br /> Compatibility Document. <br /> Page 8 of 9—DN-7111:0•9/14/2022 <br />