Laserfiche WebLink
SPECIFICATIONS <br /> SYSTEM CAPACITY is recommended that this system and its peripherals be installed in <br /> • Intelligent Signaling Line Circuits .....................1 expandable to 2 an environment with a normal room temperature of 15—27°C/60— <br /> • Intelligent detectors 159 per loop 80'F. <br /> ................................................. <br /> • Addressable monitor/control modules...................... 159 per loop AGENCY LISTINGS AND APPROVALS <br /> • Programmable software zones.................................................99 The listings and approvals below apply to the basic NFS2-640 con- <br /> • Special programming zones..................................................... 14 trol panel. In some cases, certain modules may not be listed by cer- <br /> • LCD annunciators per CPU2-640/-640E tain approval agencies,or listing may be in process. Consult factory <br /> and NCA-2 (observe power).....................................................32 for latest listing status. <br /> • ACS annunciators per o UL/ULC Listed: S635. <br /> CPU2-640/-640E..................................32 addresses x 64 points <br /> • ACS annunciators per NCA-2......32 addresses x 64 or 96 points ' Fir Approved. <br /> NOTE. The NCA-2 supports up to 96 annunciator address points per Fire Dept.of New York:#6212. <br /> ACM-24AT/--48A. • CSFM: 7165-0028:0243. <br /> • City of Chicago. <br /> ELECTRICAL SPECIFICATIONS • City and County of Denver. <br /> • Primary input power: • CCCF listed. <br /> —CPU2-640 board: 120 VAC, 50/60 Hz,5.0 A. Marine Applications:Marine approved systems must be configured <br /> —CPU2-640E board:220/240 VAC,50/60 Hz,2.5 A. using components itemized in this document. (See Main System <br /> • Current draw(standby/alarm): Components, in "Product Line Information.) Specific connections <br /> —CPU2-640(E) board: 0.250 A. Add 0.035 A for each NAC in and requirements for those components are described in the instal- <br /> use. lation document, PN 54756.When these requirements are followed, <br /> —KDM-R2:0.100 A. systems are approved by the following agencies: <br /> —LEM-320: 0.100 A. • US Coast Guard 161.002/50/0, 161.002/55/0 (Standard 46 CFR <br /> and 161.002). <br /> • Total output 24 V power:6.0 A in alarm. Lloyd's Register 11/600013(ENV 3 category). <br /> NOTE.The power supply has a total of 6.0 A. of available power. This is • American Bureau of Shipping (ABS)Type Approval. <br /> shared by all internal circuits.See Installation Manual for a complete cur- <br /> rent draw calculation sheet. NOTE.For information on marine applications,see DN-60688. <br /> • Standard notification circuits(4): 1.5 A each. STANDARDS <br /> • Resettable regulated 24V power: 1.25 A. The NFS2-640 complies with the following UL Standards and NFPA <br /> • Two non-resettable regulated 24V power outputs: 72, International Building Code (IBC), and California Building Code <br /> —1.25 A. (CBC) Fire Alarm Systems requirements: <br /> —0.50 A. • UL 864, 10th edition (Control Units and Accessories for Fire <br /> • Non-resettable 5V power:0.15 A. Alarm Systems). <br /> • Battery charger range: 18 AH—200 AH. Use separate cabinet for • UL 2610 (Commercial Premises Security Alarm Units and <br /> batteries over 26 AH. Systems). <br /> • Float rate:27.6 V. • UL 2572 (Mass Notification Systems). (NFS2-640 version 20 or <br /> higher.) <br /> CABINET SPECIFICATIONS • ULC-S527-11 Standard for the Installation of Fire Alarm Sys- <br /> • Systems can be installed in CAB-4 Series cabinets (four sizes tems. <br /> with various door options,see DN-6857). Requires BP2-4 Battery . LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- <br /> Plate. <br /> sory). <br /> SHIPPING WEIGHT • AUXILIARY(Automatic, Manual and Waterflow) (requires TM-4). <br /> • CPU2-640/-640: 14.3 Ib(6.49 kg). • REMOTE STATION(Automatic,Manual,Waterflow and Sprinkler <br /> • CPU2-640/-640E: 14.55 lb(6.60 kg). Supervisory) (requires TM-4). <br /> • PROPRIETARY(Automatic, Manual and Waterflow). <br /> TEMPERATURE AND HUMIDITY RANGES Not applicable for FM. <br /> This system meets NFPA requirements for operation at 0—49'C/32 . EMERGENCY VOICE/ALARM. <br /> —120'F and at a relative humidity 93%±2%RH (noncondensing)at . OT,PSDN(Other Technologies, Packet-switched Data Network). <br /> 32'C ± 2'C (90'F ± 3'F). However, the useful life of the system's . IBC 2012, IBC 2009,IBC 2006, IBC 2003,IBC 2000(Seismic). <br /> standby batteries and the electronic components may be adversely <br /> affected by extreme temperature ranges and humidity. Therefore, it • CBC 2007(Seismic). <br /> I® <br /> INCIMUUUU A MANUFAflUMNU <br /> QUALITY SYSTEMS <br /> This document is not intended to be used for installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> We cannot cover all specific applications or anticipate all requirements. <br /> All specifications are subject to change without notice. <br /> NOTI'FIRE•NETT.,ONYXWorksT.,and SWIFTT.are all trademarks of and Flasli <br /> N OTI FI E R can@,NOTIFIER@,ONYX@,VeriFire@ Tools,and VIEW@ are all registered trademarks of <br /> 12 Clintonville Road Honeywell Honeywell <br /> Inc. O <br /> ®ent i by Honeywell International Inc.All rights reserved.Unauthorized use of this docu- NOT 1 F 1 E R e <br /> Northford,CT 06472 ment is strictly prohibited. <br /> 203.484.7161 <br /> www.notifier.com Country of Origin:USA by Honeywell <br />