Laserfiche WebLink
18 16 14 13 12 11 10 9 8 7 6 5 4 3 2 1 <br /> ENERGY CREDITS ENERGY CODE NOTES <br /> AIR LEAKAGE OF FENESTRATION(WSEC R402.4.3) <br /> A-Plep-In Hepe Pump CREDITS PROJECT SHALL CONFORM TO THE 2018 WASHINGTON STATE S i• -- l9nv"d Greulb web•H•nprs OPTION DESCRIPTION ALL OTHERS ENERGY CODE&ANY OTHER JURISDICTIONARY REGULATIONS THAT WINDOWS,SKYLIGHTS AND SLIDING GLASS DOORS SHALL HAVE AN <br /> I <br /> L ? - ---- - - APPLY. AIR INFILTRATION RATE OF NO MORE THAN 0.3 uimPER SQUARE L <br /> mp that meets/ FN-2 For an Initial heating system using a heat pu federal standards for the equipment listed in Table C403.3.2(1)C or 0.0 1.0 FOR RESIDENTIAL:SNOHOMISH 4-C FOOT <br /> -_-_: C403.3.2(2)or Air to water heat pump units that are configured to provide both heating and cooling and are rated in accordance with AHRI OUTDOOR DESIGN TEMPERATURE(APPENDIX C) SWINGING DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO <br /> 7M r+en degree ofmmtorC 650/590 LOCATION HEATING COOLING MORE THAN 0.5 cfrn PER SQUARE FOOT WHEN TESTED <br /> ` 4.1 All supply and return ducts located in an unconditioned attic shall be deeply burled In ceiling Insulation In accordance with Section 0.0 0.5 EVERETT PRIMEFIELD 79(F) <br /> R403.3.7.For mechanical equipment located outside the conditioned space,a maximum of 10 linear feet of return duct and 5 linear feet of <br /> supply duct connections to the equipment may be outside the deeply buried insulation.All metallic ducts located outside the conditioned SYSTEMS SE ) <br /> C R403 W <br /> space must have both transverse and longitudinal joints sealed with mastic.If flex ducts are used,they cannot contain splices.Duct J <br /> ProTerra®Plug-in Heat Pump Water Heater leakage shall be limited to 3 cfm per 100 square feet of conditioned floor area.Air handier(s)shall be located within the conditioned space. (R104.1)WORK FOR WHICH A PERMIT IS REQUIRED SHALL BE <br /> 5.3 Water heating system shall include one of the following:Energy Star rated gas or propane water heater with a minimum UEF of 0.91 or 0.0 1.0 SUBJECT TO INSPECTION AND ALL WORK REQUIRED FOR CONTROLS(WSEC R403.1) <br /> with HydroBoost and Lea kGua rd Solar water heating supplementing a minimum standard water heater.Solar water heating will provide a rated minimum savings of 85 INSPECTION SHALL REMAIN VISIBLE AND ACCESSABLE UNITL <br /> therms or 2000 kWh based on the Solar Rating and Certification Corporation(SRCC)Annual Performance of OG-300 Certified Solar APPROVED AT LEAST ONE THERMOSTAT SHALL BE PROVIDED FOR EACH = <br /> (12DV Shared Circuit) r, Water Heating Systems or Water heater heated by ground source heat pump meeting the requirements of Option 3.3. SEPARATE HEATING AND COOLING SYSTEM U <br /> K Kfl1 <br /> 7.1 All of the following appliances shall-new and installed in the dwelling unit and shall meet the,Dryer standards;r rated,ve r-Energy 0.0 0.5 DUCT LEAKAGE SEC R403.3.4 Z <br /> EM�Iercy LEAK Star reud,Refrlgeretor(if provided)-Energy Surrebd,Washing machine-Energy Starreted,Dryer-Energy Surrebtl,ventleasdryer GENERAL DEFINITIONS(WSECR202) � ) O <br /> •_in m 3.5 UEF reduces operating oatl with a minimum CEF reting of 5.2. DUCTS SHALL BE TESTED AT ROUGH-IN AND POST-CONSTRUCTION <br /> AIR -ONE R MORE MATERIALS JOINED TOGETHER IN A <br /> •ENERGY STAR"'[erhflatl 0.0 3.0 AND THE RESULTS SHALL BE LESS THAN OR EQUAL TO 4 cfm PER 100 <br /> aaystain ea"Buibin leak l rg e-�ion CONTINUOUS MANNER DI RESTRICT OR PREVENT THE PASSAGE OF SQUARE FEET OF CONDITIONED FLOOR AREA. <br /> •Tde 24 Caxnpent(JAI 3I'4asay) •System detects arty leak large or THERMAL ENVELOPE(WSEC R402.1.3) AIR THROUGH THE BUILDING THERMAL ENVELOPE AND ITS BUILDING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS <br /> smeo.internal or extemal'` ASSEMBLIES <br /> Performance�Ce BUILDING THERMAL ENVELOPE-THE BELOW-GRADE WALLS,ABOVE INSTALLATION OF DUCTS IN THE BUILDING ENVELOPE SHALL NOT <br /> •OarVersnotwaermereeDCPntr/than Operation Medea COMPONENT ASSEMBLY REQUIRED PROVIDED COMMENTS DISPLACE REQUIRED INSULATION <br /> GRADE WALLS,FLOORS,CCEILINGS,ROOFS,AND ANY OTHER <br /> mast standard electric water heaters .Heat Purrp DOORS SLAB DOORS TABLE R303.1.3(2) BUILDING ELEMENT ASSSEMBLIES THAT ENCLOSE CONDITIONED <br /> •AtruentWArming range-37-14s'F •Vaca;aorA.rvay:2-28 days(aplaced FENESTRATION ALL OTHER FENESTRATION U-0.30 U-0.30 SPACE MECHANICAL SYSTEM PIPING INSULATION(WSEC <br /> ast <br /> J is wd o class,otWng mare days m hod ird9Fnaer(1 FENESTRATION-ALL GLAZING,DOORS,SKYLIGHTS OR OTHER R403.4) J <br /> otHPoperalma•mslydesgnedto FLOORS JOISTS/FRAMING R-30 R-30 PRODUCTS CLASSIFIED AS FENESTRATION <br /> meet Normern Climate Spec PHIS••• OPAQUE DOOR-A DOOR THAT IS NOT LESS THAN 50%OPAQUE IN PIPING CAPIBLE OF CARRYING FLUIDS ABOVE 105-DEGREES F SHALL <br /> (NEFA TIrr 2f •Premitm grade anode rod extends GLAZED WINDOW,GLASS DOORS NONMETAL OR METAL CLAD 0.55 DOUBLE PANE 0.55 SURFACE AREA BE INSULATED TO A MINIMUM OF R-5 <br /> •kaayazad FNdro&-i thong salvo the life of Ii a tam - ROOFS ATTIC AND OTHER R-49 R-49 RESIDENTIAL BUILDINGS-DETACHED ONE-AND TWO-FAMILY PIPING INSULATION EXPOSED TO WEATHER SHALL BE <br /> • water DWELLINGS,MULTIPLE SINGLE-FAMILY DWELLINGS(TOWNHOUSES) PROTECTED FROM DAMAGE THAT MAY DEGRADE THE MATERIAL <br /> mexmlzas ntapu[pertcrn-ance 3+'4'NPT stet and outlet; = <br /> 3J4'cpn water stain corrections WALLS,ABOVE GRADE WOOD FRAMED AND OTHER R-21 int OR R-15+5 ci R-21 AND GROUP R-2,R-3,AND RA BUILDINGS THREE STORIES OR LESS IN <br /> Easy Installation HEIGHT ABOVE GRAVE PLANE,AS WELL AS ACCESSORY SERVICE HOT WATER SYSTEMS(WSEC R403.5) <br /> •Easy arr-e�sA-connemRrn •e+aoby Swollen steel resistor STRUCTURES THERETO. <br /> elanarlls R-VALUE(THERMAL RESISTANCE)-THE INVERSE OF THE TIME RATE HOT WATER PIPES SHALL BE INSULATED TO A MINIMUM OF R.T <br /> .Factory retailed algn mAw OF HEAT FLOW THROUGH A BODY FROM ONE OF ITS BOUNDING <br /> cod-plugs d.enty into a slandarn �ltd0 1cpTO'��v+ashabg AIR BARRIER&INSULATION INSTALLATION SURFACES TO THE OTHER SURFACE FOR A UNIT TEMPERATURE HOT WATER HEATERSINUNCONDITIONEDSPACESSHALL N <br /> wet aAlm air filler DIFFERENCE BETWEEN THE TWO SURFACES OF 40 ED WITH A MINIMUM OF R-10 AND A COMPRESSIVE STRENGTH <br /> I •Esely repa:es a°tandem gee •2'Ntrn-CFC foam IaJayon COMPONENT AIR BARRIER CRITERIA INSULATION CRITERIA SLAB-ON-GRADE FLOOR-THAT PORTION OF A SLAB FLOOR OF THE OF 40 PSI <br /> water tamer •Erearlced flow brass dw valve GENERAL REQUIREMENTS A CONTINUOUS AIR BARRIER SHALL BE INSTALLED IN THE BUILDING AIR-PERMEABLE INSULATIONSHALL NOT BE USED AS A SEALING BUILDING THAT IS IN CONTACT WITH THE GROUND AND IS EITHER ELECT <br /> RICAL POWER AND LIGHTING <br /> Integration •Temperature and pressure relief valve ENVELOPE.EXTERIOR THERMAL ENVELOPE CONTAINS CONTINUOUS MATERIAL ABOVE GRADE OR LESS THAN OR EQUAL TO 24"BELOW FINISHED (WSEC R405) <br /> instated AIR BARRIER.BREAKS OR JOINTS IN THE AIR BARRIER SHALL BE GRADE NOT LESS THAN 90%OF LAMPS IN PERMENENTLY INSTALLED N <br /> •Dema^d Hespcnse Ready_ SEALED. SOLAR HEAT GAIN COEFFICIENT(SHGC)-THE RATIO OF THE SOLAR <br /> BW0-m Emport(CTA-2D45 Port '�cemfied 1c NSF,rANSI 372 ProTerra Plug-in HEAT GAIN ENTERING THE SPACE THROUGH THE FENESTRATION LIGHTING FIXTURES SHALL BE HIGH-EFFICIENCY LAMPS m <br /> ( g- CAVITY INSULAITON ALL CAVITIES IN THE THERMAL ENVELOPE SHALL BE FILLED WITH FUEL GAS LIGHTING SYSTEMS SHALL NOT HAVE CONTINUOUSLY Q <br /> alpvrs easy connection to UUlty ( Contend ASSEMBLY <br /> Heat Pump WIH1 INSTALLATION INSULATION.INSULATION SHALL SHOW NO GAPS OR VOIDS AND BURNING PILOT LIGHTS <br /> Rs'9r'a""a Warranty p MAINTAIN AN EVEN DENSITY.ALL BATT INSULATION SHALL BE Clfi U-FACTOR(THERMAL TRANSMITTANCE)-THE COEFFICIENT OF HEAT U <br /> •LED Scres1 cosh Gd0-n w•aur HydroBoost and AROUND OBSTRUCTIONS TO AVOID CRUSHING OR COMPRESSION TRANSMISSION THROUGH A BUILDING COMPONENT OR ASSEMBLY EXISTING BUILDINGS(WSEC CHAPTERS) Z F- <br /> •10-Year limited tank ar•d parts WHOLE HOUSE MECHANICAL VENTILATION SYSTEM-AN EXHAUST F- <br /> sera„aert Wh audible alarm' warranty LeakGuard W CEILING/ATTIC THE AIR BARRIER IN ANY DROPPED CEILING/SOFFIT SHALL BE THE INSULATION IN ANY DROPEED CEILING/SOFFIT SHALL BE ALIGNED SYSTEM,SUPPLY SYSTEM OR COMBINATION DESIGNED TO W W <br /> o Integrated Fsotet"WIFI-connected' SR rr•ea,ad'+ar."CW06.1e tr cmpan. (12UV$hared CirCuft) ALIGNED WITH THE INSULATION AND ANY GAPS IN THE AIR BARRIER WITH THE AIR BARRIER.BATT INSULATION IN ATTIC ROOF ASSEMBLIES EXCHANGEINDOORAIR WITH OUTDOORAIRAND OPERATES THERMOSTATSFOR ADU'S (WSEC R501.1.2) y w <br /> lam ana tree mobile "yp1rt 1- SEALED.ACCESS OPENINGS,DROP DOWN STAIRS OR KNEE WALL MAY BE COMPRESSED AT EXTERIOR WALL LINES TO ALLOW FOR <br /> H oser arP 40.50,0 an0 80-G9IIOn CONTINUALLY OR INTERMITTENTLY TO SATISFY VENTILATION RATES A SEPARATE UNIT THAT PROVIDES INDEPENDENT FACILITIES FOR H W <br /> g'�users corrtrd Inner water neater, L"N men or r9.zea Aha•xr.m+2m.ma rm2 DOORS TO UNCONDITIONED SPACESSHALL BE SEALED REQUIRED ATTIC VENTILATION LIVING SHALL BE PROVIDED WITH A SEPARATE PROGRAMMABLE <br /> wxrney lu cvewm aeatxe tc+npuatue, eee+.ea.o e:prarp,p o.o:F.aerapa•er.um-- CapaCaies WALLS THE JUNCTION OF THE FOUNDATION AND SILL PLATE SHALL BE CAVITIES WITHIN CORNERS AND HEADERS OF FRAME WALLS SHALL THERMOSTAT F- F- <br /> vacation s d cyst martlrg.energy f NAC�th�•[xedeeo cc� di 120 Volt/1 PH SEALED.THE JUNCTION OF THE TOP PLATE NAD THE TOP OF BE INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL MATERIALS SYSTEMS&EQUIPMENT(WSEC R303) Z W <br /> hangs and system man:orrg at ee ,nyr Pnl�"anoentna EISCIhC EXTERIOR WALLS SHALL_BE SEALED.KNEE WALLS SHALL BE SEALED HAVING A THERMAL RESISTANCE OF R-3 PER INCH MINIMUM. MATERIALS,SYSTEMS AND EQUIPMENT SHALL BE IDENTIFIED IN A <br /> bane or sway WINDOWS,SKYLIGHTS AND THE SPACE BETWEEN WINDOW/DOOR JAMBS AND FRAMING AND MANNER THAT WILL ALLOW A DETERMINATION OF COMPLIANCE ADDITIONS (WSEC R502) a F- <br /> •I iagrated lash detector and DOORS SKYLIGHTS AND FRAMING SHALL BE SEALED WITH THE APPLICABLE PROVISIONS OF THE CURRENT WSEC <br /> orlon stern with tact' uxe :rrs;wmsv.,w n•..a..mA.• ADDITIONS TO AN F�(ISTING BUILDING,BUILDING SYSTEM OR pp F- <br /> paws 4y aY :b,;,m e,y„„a,ao-eyQ1,1 Me„y 4 RIM JOISTS RIM JOISTS SHALL INCLUDE THE AIR BARRIER FLOOR FRAMING CAVITY INSULATION SHALL BE INSTALLED TO R-VALUE MARK SHALL BE APPLIED BY THE MANUFACTURER TO 7 <br /> mauled auto water shut-off valve °A"""'ern w950pap+u.ro•awap'a.. 'iO10'^'��"' MAINTAIN PERMANENT IN CONTACT WITH THE UNDERSIDE OF PORTION THEREOF SHALL CONFORM TO THE PROVISIONS OF THE o Z <br /> + EACH PEICE OF THE BUILDING THERMAL ENVELOPE.INSULATION rr <br /> omits leeks to m mart then 20 � ^+f16*•'^mi00"awwvpmaxwn cons WSEC WITHOUT REQUIREING THE UNALTERED SYSTEM TO COMPLY <br /> weer r.,•o,.cw..,y awrwms SUBFLOOR DECKING OR FLOOR FRAMING CAVITY INSULATION SHALL SHALL BE INSTALLED SUCH THAT THE MANUFACTURERS MARK IS <br /> otnces d water"' -ua•x n,..".u,..osswr,.x.nwor. BE PERMITTED TO BE IN CONTACT WITH THE TOPSIDE OF SHEATHING THIS INCLUDES: Q <br /> dfA'�'-,..n•,,...a.vpa+o'><w„, ff READILY OBSERVABLE UPON INSPECTION BUILDING ENVELOPE <br /> OR CONTINUOUS INSULATION INSTALLED ON THE UNDERSIDE OF BLOWN IN OR SPRAYED INSULATION THICKNESS SHALL BE HEATING AND COOLING SYSTEMS ao <br /> G FLOOR FRAMING AND EXTEND FROM THE BOTTOM 70 THE TOP OF ALL WRITTEN IN INCHES IN MARKER FOR EVERY 300 SQUARE FEET OF SERVICE HOT WATER SYSTEMS G o <br /> ..r...-.•, PERIMETER FLOOR FRAMING MEMBERS n <br /> ' AREA THROUGHOUT THE SPACE.MARKERS SHALL BE AFFIXED TO LIGHTING <br /> FLOORS(INCLUDING ABOVE THE AIR BARRIER SHALL BE INSTALLED AT ANY EXPOSED EDGE OF FLOOR FRAMING CAVITY INSULATION SHALL BE INSTALLED TO PERMANENT STRUCTURE. <br /> See speclficatlons chart on next page.. UNHEATED SPACE) INSULATION. MAINTAIN PERMANENT IN CONTACT WITH THE UNDERSIDE OF FENESTRATION PRODUCT RATING SHALL BE NOTED ON <br /> SUBFLOOR DECKING OR FLOOR FRAMING CAVITY INSULATION SHALL MATERIALS.PRODUCTS LACKING SUCH A LABEL SHALL BE ASSIGNED ALTERATIONS (WSEC R503) <br /> BE PERMITTED TO BE IN CONTACT WITH THE TOPSIDE OF SHEATHING A DEFAULT U-FACTOR <br /> OR CONTINUOUS INSULATION INSTAL ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY <br /> CRAWLSPACE WALLS EXPOSED EARTH IN UNVENTED CRAWL SPACES SHALL BE COVERED WHERE PROVIDED INSTEAD OF FLOOR INSULATION,INSULATION BUILDING ENVELOPE REQUIREMENTS SEC R402) WITH THE REQUIREMENTS OF THE WSEC FOR NEW CONSTRUCTION <br /> WITH A CLASS 1,BLACK VAPOR RETARDER MATH OVERLAPPING SHALL BE PERMANENTLY ATTACHED TO THE CRAWLSPACE WALLS. SUCH THAT THE EXISTING BUILDING SHALL BE NO LESS <br /> JOINTS TAPED CONFORMING TO THE CURRENT PROVISIONS AS IT WAS PRIOR TO <br /> SHAFTS AND PENETRATIONS DUCT SHAFTS,UTILITY PENETRATIONS,AND FLUE SHAFTS OPENING GENERAL(PRESCRIPTIVE)(WSEC R402.1) THE ALTERATION. <br /> ru IN= - - TO EXTERIOR OR UNCONDITIONED SPACE SHALL BE SEALED. E <br /> 0 <br /> F Architect: GC; �v NARROW CAVITIES BATTS IN NARROW CAVITIES SHALL BE CUT TO FIT AND INSTALLED TO LOW-ENERGY BUILDINGS AND SPACES SHALL BE SEPARATED FROM F cP <br /> THE CORRECT DENSITY WITHOUT ANY VOIDS OR GAPS OR THE REMAINDER OF THE BUILDING BY USE OF A BUILDING THERMAL <br /> Enar: Mach: COMPRESSION,OR NARROW CAVITIES SHALL BE FILLED BY ENVELOPE v, <br /> INSULATION THAT ON INSTALLATION READILY CONFORMS TO THE <br /> Rep: AVAILABLE CAVITY SPACE H t^ s <br /> GARAGE SEPARATION AIR SEALING SHALL BE PROVIDED BETWEEN THE GARAGE AND <br /> EAVE BAFFLE(WSEC R402.2.3) <br /> �� = CONDITIONED SPACES FOR AIR PERMEABLE INSULATIONS IN VENTED ATTICS,A BAFFLE OF V Ix N <br /> RECESSED LIGHTING RECESSED LIGHT FIXTURES INSTALLED IN THE BUILDING THERMAL ANY SOLID MATERIALSHALL BE INSTALLED ADJACENT TO SOFFIT AND IaI lea« °i <br /> Urr.,C,,,d ENVELOPE SHALL BE SEALED TO THE FINISHED SURFACE EAVE VENTS TO MAINTAIN AN OPENING EQUAL TO OR GREATER o rn a <br /> '• f - PLUMBING AND WIRING BATT INSULATION SHALL BE CUT NEATLY TO FIT AROUND WIRING AND THAN THE SIZE OF THE VENT. F Z <br /> U)� Ot <br /> pe to met - PLUMBING IN EXTERIOR WALLS.THERE SHALL BE NO VOIDS OR GAPS LU m <br /> Oper•sthg lunge: OR COMPRESSION WHERE CUT TO FIT.INSULATION THAT ON - Z O2 <br /> E [oaln: outdooruol: INSTALLATION READILY CONFORMS TO AVAILABLE SPACE SHALL ACCESS HATCHES ANDDOORS(WSECR402.2.4) E _ ,,a <br /> odiiy tap•oty(Min-Arced-Max,etuth) 16,900-•42•p00-SOAao CaoIN-('F DaI 51011E EXTEND BEHIND PIPING AND WIRING ACCESS DOORS FROM CONDITIONED SPACES TO UNCONDITIONEDW9VSHOWERRUB ON EXTERIOR THE AIR BARRIER INSTALLED AT FJCTERIOR WALL3 ADJACENT TO EXTERIOR WALLS ADJACENT TO SHOWERS AND TUBS SHALL BE m <br /> -,ow.,..r•n.. u•o-.frn..,•r•". SPACES SHALL N TOWEATHERSTRIPPED OUNDANDINSULATEDTOA y c <br /> Indoor Unit WALL SHOWERS AND TUBS SHALL SEPARATE THE WALL FROM THE INSULATED <br /> Heats �• LEVELEQUNALENT TO THE SURROUNDING SURFACES IN SUCH A <br /> Hearne Capadty(MiWilmd-Mae Btulhf 18,It0a'48,OOD-6a,D00 Cppline('F WB) 57 to 77 SHOWERS AND TUBS WAY THAT INSULATION VALUE IS MAINTAINED THROUGHOUT e <br /> 45PF 11.0 Heating.(•F Dal Somali ELECTRICAUPHONE BOX ON THE AIR BARRIER SHALL BE INSTALLED BEHIND ELECTRICAL OR OPERATION <br /> EXTERIOR WALL COMMUNICATION BOXES OR AIR SEALED BOXES SHALL BE INSTALLED m N <br /> Mae hearing @ rodoor70.08 iBt41h) 52 200 stem oats: HVAC REGISTER BOOTS HVAC SUPPLY AND RETURN REGISTER BOOTS SHALL BE SEALED TO FRAMED FLOORS WSEC R402.2.7 <br /> o.w.orll°F WR Rafrlli r mTywXontrul RA10A/EEV ( ) <br /> oe doe 5•F Wa THE SUBFLOOR,WALL COVERING OR CEILING PENETRATED BY THE <br /> Outdoor 4F We 38,200 Prfriewam Charp(lye.) 9.26 BOOT CAVITY INSULATION IN FLOOR FRAMING SHALL SINE INSTALLED TO c o <br /> Outdoor-13F W9 28 810 OW Sound Praswre Maa(Cool/Heart El WWI 54/56 CONCEALED SPRINKLERS WHEN REQUIRED TO BE SEALED,CONCEALED FIRE SPRINKLERS MAINTAIN PERMANENT CONTACT WITH THE UNDERSIDE OF THE a too <br /> rar.«�•"+•"•ra a.m,".•..«m IDU Sound Pressure WMIU dl d&AY 4914$144 SHALL ONLY BE SEALED IN A MANNER THAT IS RECOMMENDED BY SUBFLOOR DECKING.SUPPORTS SHALL BE INSTALLED AT SPACING r� <br /> D uo w.wnex<o-o,v.�. wa•I no-«d en a..am., ODU Net?Shipping WerBM(14s.1 2109/2341 THE MANUFACTURER.CAULKING OR OTHER ADHESIVE SEALANTS OF NO MORE THAN 24-INCHES o.e. D <br /> addIMISIP 01114"v.e m <br /> oroun•r oFr+s•rw o,sKKar ar•uro•r ere IDU Net?Shipping weight l®s.) 158.71176.4 SHALL NOT BE USED TO FILL VOIDS BETWEEN FIRE SPRINKLER WHERE FOUNDATION VENTS ARE NOT PLACED BELOW THE PERMIT APPROVAL STAMPS "'• <br /> Eleetrlal: n: COVER PLATES AND WALLS OR CEILINGS LOWER SURFACE OF FLOOR INSULATION,A PERMANENTLY m <br /> Power5upp0r'(VMtIDI 20&230/GoI T INSTALLED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30-DU cov <br /> MOP/MrA(AI 901g2 0 /IDUFan TyPe Prdpeavisooeod DEGREES FROM HORIZONTAL TO DIVERT AIRFLOW BELOW THE r <br /> Coding l Heading Rated Ampe(A) 14.9116.4 Fan Speeds IFWJCoaIJHaet) 31313 INSULATION SURFACE <br /> CompnssalAl 22.4 <br /> Fan a vappry(oDu.Ioul 2.1 <br /> FanMamr(IDLJ.OD lj(A) 1.3.(16x21 Mat."Mrive BrurhhssDiptallyCoamoll eiJD'.d SLAB-ON-GRADE FLOORS(WSEC R402.2.9) <br /> Cooling Poway InNui(Min-Raied-M&%kWI 1.19-3.36-532 Mad.-OOU Air V.I...(CFMI 4,23E <br /> Hearing Power Input(Mir-Rated-Max,%WI 1.34-3.69-5.8 IDU Aa Volume MINIM(CFMI 1,26a 11.1DO 11,000 FPERIMETER INSULATION REQUIRED SHALL BE PLACED ON THE o <br /> OUTSIDE OF THE FOUNDATION OR THE INSIDE OF THE FOUNDATION <br /> Looked Rau.Amps(A) 33 0ekumidir Fort Pate IpLVhr)" 6-76 WALL.THE ISULATION SHALL EXTEND DOWNWARD FROM THE TOP li - <br /> C - o,...r.mn.w®. ere•m,",..•,c,•raa,."•rr IDU Emmal Sr k Pressure Op..Hna OF THE SLAB TO THE TOP OF THE FOOTING(MINIMUM FROM THE TOP C <br /> Plpin Range(Min-Oee*-Max){in-wgl" 0.1-03-1.0 OF SLAB TO THE BOTTOM OF SLAB)OR THE REQUIRED DISTANCE -'3 <br /> MsuIIM liquid Pipe(In.,0-0.) l!a Pure (WHICHEVER IS LESS).IF THE REQUIRED DISTANCE IS NOT ACHIEVED <br /> Metalled Vapor Aye her,o,pl Ste we Nobs: THE REMAINING DISTANCE SHALL BE LOCATED HORIZONTALLY <br /> t.urawd.o_ whoa•:trn-iota THE ENTIRE AREA OF HEATED SLABS SHALL BE THERMALLY <br /> IOU Laud CanrccHi 11n.,o-0.) Us Flare 2.Por°rem, ,emir. <br /> IOU Vapor eonnecUon m., 3.S°"•�e"+a"rcle..`'tom`a°'"'"a"ac°"°'r'"°°""ecr'ro....W.. ISOLATED FROM THE SOIL <br /> I OA.I 918 Flare gnNi pwwrmm••unudmulwpmmmPlwmHx,•ar,a.r:,�aary[+atex�GS.ixaam <br /> Additional Refriear am wt.) <br /> p.y r4unocamara,siHmopr,nsr:aae,apmem,a omit' <br /> ( Ic,tle nsr:tlara.ma.ram,s+aPP.newmeli.made a+nr mwpp`r uu cnM <br /> e„«nNru.e:am,n wm+mapw,aoararaiarenmw«aa. AIR LEAKAGE(WSEC R402.4) <br /> MIrVMax.PlpalRnglh(k-I 16,e/2u E.,.a;.aa.r"na,p.,�.enaR'dr,.na PROJ.NO: <br /> 2.w,mm'e rxee D r<ewar s�eaL.an°1t�en:n nmpumr to aro a on.lrw q CONTINUOUS AIR BARRIER SHALL BE PROVIDED THROUGHOUT <br /> Piping Lanphino add'I ramB.,RJ 249 dMnra.rhatwam uwiaax and"•iro•prunc <br /> Max.Elevason(h I 98.4 °sarini "IUmaivei,'oo•:.wh3iiai2i+'tgrwai+iea.nmv:,mhmirnnPdmev THE BUILDING THERMAL ENVELOPE.AIR BARRIER SHALL BE 22031 <br /> OR oa`Rm. CONTINUOUS AND ALL JOINTS AND SEAMS SHALL BE SEALED <br /> H Danuwalw is Wwmi yemote a,m. <br /> UreF 11 vs.2ak aro ear rou.nax m.e EW u.rMl a,np�•.nrytr,,a4uve mm.yau rra erP INCLUDING ALL TRANSITIONS AND CHANGES IN MATERIALS.ALL PERMIT <br /> B Hot rbrt •ayep pamrel .opu Drain PY,Wat•r ISmtic Pmuv.im'W.muN°m.+Mn,sna edam 6P.anror e•aaa urt¢ B <br /> •InvPnar{wrlahb•p••e}•Tsm•rlaNetp Mpnttwut s,r,cmn 12 ieiaro2a ww,a.rupaaw.xnrmmampam+x pee pamlema. PENETRATIONS N THE BARRIER SHALL BE CAULKED,GASKETED DRAWN BY:RBC <br /> •Auu mean silo Moro 2,1 ®*with ,i.uda.n..,.,.•ce.u,rwr+rl.mexw,sin,bw,tnw,u4w,.,a Dpxw OR OTHERWISE SEALED IN A MATTER COMPATIBLE WRH THE <br /> vCOilurmiabanr«n°n.ewi't,naai rwysmnri maapiV24x,3sa c'"""„`a°°"°".•"ai"'w"e'n'r.,xinm�sl. CONSTRUCTION MATERIALS-INCLUDING RECESSED LIGHT CHECKED BY:MUG <br /> da.cpnonta"m'nmeM. FIXTURES AND JUNCTION BOXES.AIR INTAKES,EXHAUSTS AND ISSUE DATE:0310312023 <br /> Requited Aweseorles(sold separately): SHAFTS SHALL BE PROVIDED WITH DAMPERS.DOORS AND SCALE:12"-1'-0" <br /> C-Ser 1A,,r 16, d-cpnnoler) WINDOWS SHALL BE GASKETED,WEATHERSTRIPPED OR SEALED. <br /> 1-'n <br /> cwseorissINSTALLATION REQUIREMENTS SHALL BE IN ACCORDANCE WITH THE <br /> F."111,;1n. <br /> CPC]-PPEMCIAuxr* Re4V4h-P HI AIR BARRIER&INSULATION INSTALLATION SCHEDULE(THIS SHEET)RCu-PPfl4yTHE BUILDING SHALL BE TESTED WITH A BLOWER DOOR TESTAT ENERGY CODE n•omm.Mp- o4�.aw Ame*n+4AadeWlle It.ling A PRESSURE OF 0.21NCHES w. ADN SHALL NOT EXCEED A RATE OF-P4c55Ap4p .:bran oa-t•r1-ztARGpaA' g eQi <br /> CIACPS-0005A000 pf*ok Heiner 3Lw-AW.W3R1" 5 AIR CHANGES PER HOUR REQUIREMENTS <br /> Mimi*FOnbdl:r-PR IWITCOIN Qoaa+uio.vfmwrrim xlt-PNCep] O <br /> A 0cos-FmodulP PWTMDOM LGRED FIREPLACES(WSEC R402.4.2) A <br /> R_W T..W0IVa Sema- <br /> �2RTe501 Pvaerh.l He+e,.cnnan4y L--" C U9 <br /> NEW WOOD BURNING FIREPLACES SHALL HAVE TIGHT-FITTING N <br /> re arwiaiN ma«amk.::....a.,m,,.a w+sc,•"....,�.,• DAMPERS OR DOORS.GAS FIREPLACE HEATERS SHALL BE LISTED <br /> i,r ern•-.e p„u s b.vluam,n,iL nwrr•e•,rah,w,n.,p nw,.d.a•o"..m"m nmu. 5e-St�1.GPFp VAHU_1V420HHw 2D21_p5_25 132123 AND LABELED WITH A FIREPLACE EFFICIENCY OF 50%OR GREATER G3.00 <br /> p iL fl.•nu-.:W S0.Im,EMmwne Gn.ILLMIr•I:n rwr•w.la.bLlGmt'e•rcdnwlr.,a,me,d lL fcra:••.I,Invr.con, Paprtors 18"x12"DRAWINGS ARE1/2 SIZE SCALE NOTED <br /> % <br /> 18 16 14 13 12 11 10 9 8 7 6 6 4 IF LINE DOES NOT MEASURE 1"SHEET IS NOT TO SCALE <br /> IF ANY DISCREPENCIES ARE FOUND,NOTIFY ARCHITECT IMMEDIATELY.VERIFY CONDITIONS AND DIMENSIONS IN FIELD. <br />