Laserfiche WebLink
l 1- ixlr ilex Open Energy For All <br /> \J Technical Specifications <br /> Model HM-1200NT HM-1500NT <br /> Input Data(DC) <br /> Commonly used module power(W) 240 to 405+ 300 to 505+ <br /> Maximum input voltage(V) 60 <br /> MPPT voltage range(V) 16-60 <br /> Start-up voltage(V) 22 <br /> �+ Maximum input current(A) 4 x 11.5 4 x 11.5 <br /> Maximum input short circuit current(A) 4 x 20 <br /> Number of MPPTs 2 <br /> Number of inputs per MPPT 2 <br /> Output Data(AC) <br /> _ Peak output power(VA) 1200 1200 1500 1500 <br /> Maximum continuous output power(VA) 1200 1200 1438 1438 <br /> Maximum continuous output current(A) 5.00 5.77 5.99 6.91 <br /> Nominal output voltage/range(V)' 240/211-264 208/183-228 240/211-264 208/183-228 <br /> Nominal frequency/range(Hz)' 60/55-65 <br /> Power factor(adjustable) >0.99 default <br /> 0.8 leading...0.8 lagging <br /> Total harmonic distortion <3% <br /> • Description Maximum units per 10AWG branch 4 4 4 3 <br /> Hoymiles 4-in-1 microinverter is one of the most cost-effective Efficiency <br /> module-level solar solutions,as it can support up to 4 panels at CEC peak efficiency 96.7% <br /> once and maximize the PV production of your installation.With a CEC weighted efficiency 96.5% <br /> maximum DC voltage of 60 volts,Hoymiles microinverter is a PV <br /> Nominal MPPT efficiency 99.8°/0 <br /> Rapid Shutdown Equipment and conforms with NEC-2017 and <br /> NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. Nighttime power consumption(mW) <50 <br /> H M-120ONT Mechanilcal Data <br /> H M-150 NT Both models listed are equipped with reactive power control and Ambient temperature range(°C) -40 to+65 <br /> can meet the requirements of IEEE 1547,UL 1741 and CA Rule21. Dimensions(W x H x D mm) 280 x 176 x 33 <br /> Weight(kg) 3.35 <br /> Enclosure rating Outdoor-NEMA 6(IP67) <br /> Cooling Natural convection-No fans <br /> Features Features <br /> Communication 2.4 GHz Proprietary RF(Nordic) <br /> • Easy installation,just plug and play Type of isolation Galvanically Isolated HF Transformer <br /> VAEOxternal antenna for stronger communication with DTU Monitoring S-Miles Cloud' <br /> With Reactive Power Control,compliant <br /> with CA Rule 21 Warranty Up to 25 years <br /> High reliability:NEMA 6(I1367)enclosure, Compliance UL 1741,IEEE 1547,UL 1741 SB,UL 1741 SA(240 Vac),CA Rule 21 (240 Vac)', <br /> Compliant with U.S.NEC-2017&NEC-2020 <br /> 6000 V surge protection CSA C22.2 No.107.1-16,FCC Part 15B,FCC Part 15C <br /> PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 <br /> 690.12 rapid shutdown P and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems <br /> *1 Nominal voltage/frequency range can vary depending on local requirements. <br /> *2 Refer to local requirements for exact number of microinverters per branch. <br /> *3 Hoymiles Monitoring System <br /> *4 The HM-150ONT microinverter complies with both CA Rule 21 (240 Vac)and CA Rule 21 (208 Vac). <br /> ©2024 Hoymiles Power Electronics Inc.All rights reserved. <br />