Laserfiche WebLink
(*Imile5 Open Energy For All <br /> Technical Specifications <br /> Model H M-60ONT H M-700 NT H M-800NT <br /> Input Data(DC) <br /> Commonly used module power(W) 240 to 405+ 280 to 470+ 320 to 540+ <br /> Maximum input voltage(V) 60 <br /> MPPT voltage range(V) 16.60 <br /> Start-up voltage(V) 22 <br /> _ Maximum input current(A) 2 x 11.5 2 x 11.5 2 x 12.5 <br /> �^ Maximum input short circuit current(A) 2 x 20 <br /> Number of MPPTs 2 <br /> Number of inputs per MPPT 1 <br /> Output Data(AC) <br /> Peak output power(VA) 600 700 800 <br /> Maximum continuous output power(VA) 590 696 766 <br /> Maximum continuous output current(A) 2.46 2.84 2.90 3.35 3.19 3.68 <br /> Nominal output voltage/range(V)' 240/211-264 208/183-228 240/211-264 208/183-228 240/211-264 208/183-228 <br /> Nominal frequency/range(Hz)' 60/55-65 <br /> Power factor(adjustable) >0.99 default <br /> 0.8 leading...0.8 lagging <br /> Total harmonic distortion �3% <br /> Description Maximum units per 10AWG branch 8 8 7 7 6 <br /> Maximum units per 12 AWG branch 6 5 5 4 5 4 <br /> Hoymiles 2-in-1 microinverter can connect up to 2 panels at Efficiency <br /> once and maximize the PV production of your installation.With CEC peak efficiency 96.7% <br /> a maximum DC voltage of 60 V,Hoymiles microinverter is a PV CEC weighted efficiency 96.5% <br /> Rapid Shutdown Equipment and conforms with NEC-2017 and Nominal MPPT efficiency 99.8% <br /> H M-60ONT NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. Nighttime power consumption(mW) <50 <br /> HM-70ONTI <br /> Mechanical Data <br /> All of the three models listed are equipped with reactive power Ambient temperature range(°C) -40 to+65 <br /> H M-80ONT control and can meet the requirements of IEEE 1547,UL 1741 Dimensions(W x H x D[mm)) 250 x 170 x 28 <br /> and CA Rule21. Weight(kg) 2.6 <br /> Enclosure rating Outdoor-NEMA 6(IP67) <br /> Cooling Natural convection-No fans <br /> Features Features <br /> Communication 2.4 GHz Proprietary RF(Nordic) <br /> Type of isolation Galvanically Isolated HF Transformer <br /> Easy installation,just plug and play V' Eoxternal antenna for stronger 9 Monitoring 5-Miles Cloud' <br /> munication with DTU <br /> � With Reactive Power Control,compliant Warranty Up to 25 years <br /> with CA Rule 21 Compliance UL 1741,IEEE 1547,UL 1741 SA(240 Vac),UL 1741 SB,CA Rule 21(240 Vac)', <br /> High reliability:NEMA 6(IP67)enclosure, CSA C22.2 No,107.1-16,FCC Part 15B,FCC Part 15C <br /> 6000 V surge Compliant with U.S.NEC-2017&NEC 2020 protection PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020Article 690.12 <br /> 690.12 rapid shutdown and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems <br /> *1 Nominal voltage/frequency range can vary depending on local requirements. <br /> *2 Refer to local requirements for exact number of microinverters per branch. <br /> *3 Hoymiles Monitoring System <br /> *The HM-80ONT microinverter complies with both CA Rule 21 (240 Vac)and CA Rule 21 (208 Vac). <br />