My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2316 KENILWORTH PL 2025-12-01
>
Address Records
>
KENILWORTH PL
>
2316
>
2316 KENILWORTH PL 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2025 1:55:57 PM
Creation date
11/20/2025 1:55:57 PM
Metadata
Fields
Template:
Address Document
Street Name
KENILWORTH PL
Street Number
2316
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
METAL CONDUIT REQUIRED FOR DC CONDUCTORS AMBIENT TEMPERATURE SPECIFICATIONS SOLAR MODULE SPECIFICATIONS <br /> THAT ARE RAN INTERIOR OF BUILDING CONTRACTOR <br /> RECORD LOW TEMP _5°C MANUFACTURER/MODEL# SILFAB SOLAR SIL-440 OD(440W) <br /> MCI'S TO BE WIRED IN SERIES EVERY 3 MODULES AMBIENT TEMP(HIGH TEMP 2%AVG.) 26°C VMP 33.41V <br /> SILFAB SOLAR AND 1 MCI AT THE BEGINNING OF THE STRING IMP 13.17 A <br /> SIL-440 OD(440W) MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE 7/8" <br /> vOC 38.97 v BLOSSOM SOLAR <br /> 6 ISC 14.22 A <br /> TEMP.COEFF.VOC -0.24%/°C <br /> (N)TESLA 1538000-7.6-Y,(240V) <br /> MCI'S TO BE WIRED IN SERIES EVERY 3 MODULES (N)JUNCTION BOX OUTPUT:240 VAC,32A <br /> SILFAB SOLAR AND MCI TTHE BEGINNIN OF THE STRING 600 V,NEMA 3R N EMA 3R,UL LISTED METER#:1000550561 BLOSSOM SOLAR <br /> SIL-440 QD(440W) UL LISTED TO UTILITY GRID <br /> L1L2 N <br /> 1 2 DG <br /> ACA <br /> LINE (E)BI-DIRECTIONAL <br /> ° (N)125A DEDICATED UTILITY METER #3507 ARLINGTON,WA, 98223 <br /> o PV COMBINER M 1-PHASE,3-W, <br /> MCI'S TO BE WIRED IN SERIES EVERY 3 MODULES PANEL,240V (N)AC DISCONNECT: <br /> SILFAB SOLAR AND 1 MCI AT THE BEGINNING OF THE STRING LOAD 120V/240V <br /> SIL-440 CID(440W) (BR816L125RP) VISIBLE,LOCKABLE,LABELED <br /> LIC. NO. -0 <br /> 3 200A FUSED,(2)125A FUSES, <br /> 240V,NEMA 3R,UL LISTED SUPPLY SIDE <br /> z a a s s Li L1 L1 CONNECTION <br /> L2 L2 L2 <br /> N N (E)200A/2P MAIN <br /> G G II BREAKER,240V <br /> METAL CONDUIT REQUIRED FOR DC CONDUCTORS 40AI2P 4 <br /> THAT ARE RAN INTERIOR OF BUILDING <br /> (E)200A MAIN <br /> 40AI2P SERVICE PANEL, <br /> MCI'S TO BE WIRED IN SERIES EVERY 3 MODULES 240V <br /> SILFAB SOLAR AND 1 MCI AT THE BEGINNING OF THE STRING <br /> SIL-440 QD(440W) 40A/2P <br /> z a a L <br /> s N SUPPLY SIDE <br /> INTERCONNECTION <br /> O AT MAIN PANEL <br /> N <br /> —, (N)TESLA 1538000-7.6-Y,(240V) G DEC <br /> 32A 240 VAC, <br /> MCI'S TO BE WIRED IN SERIES EVERY 3 MODULES (N)JUNCTION BOX OUTPUT: EXISTING GROUNDING <br /> SILFAB SOLAR AND 1 MCI T THE BEGINNIN OF THE STRING I 600 V,NEMA 3R NEMA 3R,UL LISTED ELECTRODE SYSTEM <br /> SIL-440 QD(440W) I UL LISTED <br /> I <br /> DG J 5 ] <br /> PROJECT NAME &ADDRESS <br /> 1 2 3 fi <br /> AC <br /> 0 <br /> MCI'S TO BE WIRED IN SERIES EVERY 3 MODULES PETER LABIB <br /> SILFAB SOLAR AND 1 MCI AT THE BEGINNING OF THE STRING <br /> SIL-440 OD(440W) I , 2316 KENILWORTH PL, <br /> I 3 aE3 EVERETT, WA, 98203 <br /> I <br /> a 5 8 I <br /> APN#: 00734800001300 <br /> METAL CONDUIT REQUIRED FOR DC CONDUCTORS AHJ: CITY OF EVERETT <br /> THAT ARE RAN INTERIOR OF BUILDING UTILITY: SNOHOMISH COUNTY <br /> SILFAB SOLAR MCI'S TO BE WIRED IN SERIES EVERY 3 MODULES PU D <br /> SIL-440 QD(440W) AND 1 MCI AT THE BEGINNING OF THE STRING <br /> 1�11111 Ift-All, 111:161 if i L SYSTEM DETAILS <br /> DC SIZE:21.120 KW DC-(STC) <br /> AC SIZE:22.800 KW AC <br /> MCI'S TO BE WIRED IN SERIES EVERY 3 MODULES <br /> (N)TESLA 1538000-7.6-Y,(240V) 48 SILFAB SOLAR SIL-440 QD 440W <br /> AND 1 MCI AT THE BEGINNING OF THE STRING I (N)JUNCTION BOX OUTPUT:240 VAC,32A ( )TESLA 1538000-7.6-Y,(24oV) <br /> SILFAB SOLAR I 600 V,NEMA 3R NEMA 3R,UL LISTED INVERTER SPECIFICATIONS (0303)TESLA PV RAPID SHUTDOWN MCI-2(1 PER <br /> SIL-440 QD(440W) UL LISTED <br /> MANUFACTURER/MODEL# TESLA 1538000-7.6-y 3 MODULE) <br /> °C POWER RATING 760OW <br /> ° Ac MAX CONT.OUTPUT CURRENT 32A REVISIONS <br /> o MAX CURRENT PER MPPT(IMP) 13A2 <br /> II II MAX DC VOLTAGE 600V REV DESCRIPTION DATE <br /> 1 I� MAX SHORT CIRCUIT CURRENT 2 <br /> 3 PER MPPT(ISC) 17A <br /> DESCRIPTION FORMULA RESULT <br /> PV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25= (03 x 32)A x 1.25 120.00A (SELECTED OCPD = 125A) <br /> DC WIRE CALCULATION <br /> EXPECTED TEMP QTY OF CURRENT CONDUIT MINIMUM CONDUCTOR CONDUCTOR REQUIRED CIRCUIT <br /> WIRE WIRE GAUGE& ADJUSTED CONDUCTOR NEUTRAL CONDUCTOR GROUND WIRE <br /> ID WIRE TEMP DERATE CARRYING FILL CONDUIT SIZE TYPE AMPACITY @ 90°C AMPACITY @ 75°C CONDUCTOR AMPACITY AMPACITY @ 90°C(A) SIZE&TYPE SIZE&TYPE SHEET TITLE <br /> (°C) (90°C) CONDUCTORS DERATE (TBD ON SITE) (A) (A) (A) ELECTRICAL <br /> 1 29 1 6 IN AIR N/A #10 AWG PV 40 35 18.75 40 NONE #6 AWG BARE <br /> WIRE Cu DIAGRAM <br /> 2 29 1 6 1 0.8 3/4"METAL #10 THWN-2 40 35 18.75 32 NONE #10 THWN-2 DRAWN DATE 4/11/2025 <br /> Al 29 1 4 IN AIR N/A #10 AWG PV 40 35 18.75 40 NONE #6 AWG BARE <br /> WIRE Cu DRAWN BY AN <br /> A2 29 1 4 0.8 3/4" METAL #10 THWN-2 40 35 18.75 32 NONE #10 THWN-2 <br /> AC WIRE CALCULATION SHEET NUMBER <br /> 3 29 1 2 1 3/4" METAL #8 THWN-2 55 50 40 55 #8 THWN-2 #10 THWN-2 �`V,_O� <br /> 4 29 1 2 1 1-1/4" METAL #2 THWN-2 130 115 120 130.00 #2 THWN-2 #6 THWN-2 <br /> 5 29 1 2 1 1-1/4" PVC #2 THWN-2 130 115 120 130.00 #2 THWN-2 #6 THWN-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.