Laserfiche WebLink
City of Everett Permit Services <br /> EVERETT Reviewed for Permit 03/05I2025 <br /> PUMP SCHEDULE LEGEND <br /> CAPACITY SIZE VOLTS/ MOTOR FLA WEIGHT SEE SHEET 40-009-MlA <br /> TAG NO. LOCATION AREA SERVED TYPE (GPM) TDH(FT) DISCHARGE MOTOR HP PHASE AMPS(A) RPM (LBS) NOTES <br /> (INCH) <br /> P-1 BUILDING40-09 40-09 BUILDING SUMP PUMP 60 20 2 1/2 120/1 2.6 3450 90 1 <br /> SUMP GENERAL NOTES <br /> PUMP NOTES'. <br /> 1. PROVIDE DUCT MOUNTED AIR VELOCITY SENOR. INSTALL <br /> 1)PROVIDE PUMP WITH EXPLOSION PROOF MOTOR.PUMP SHALL BE RATED FOR INSTALLATION IN A CLASS 1,DIV 2 LOCATION. SENSOR STRICTLY PER MANUFACTURER'S INSTRUCTIONS. <br /> 2)FURNISH PUMP WITH SIMPLEX INSTRINSICALLY SAFE CONTROL PANEL WITH NEMA 4X ENCLOSURE AND 3-FLOAT SWITCH CONTROL. <br /> 2. WALL FAN VELOCITY SENSOR (FIT 13) AND ROOF FAN <br /> VELOCITY SENSORS (FIT 11 AND FIT 12) SHALL <br /> CONTINUOUSLY MONITOR THE AIRFLOW VELOCITY IN <br /> THEIR RESPECTIVE DUCTS. WHEN THE VELOCITY <br /> 500 CFM 500 CFM DETECTED BY FIT 13 IN COMBINATION WITH ANY ROOF <br /> FAN VELOCITY FIT 11 AND FIT 12 SENSORS DROPS TO <br /> 900 FEET PER MINUTE (FPM) OR LESS, THE SENSOR <br /> SHALL SEND A SIGNAL TO THE BUILDING MANAGEMENT <br /> SYSTEM (BMS), AND EMS SHALL GENERATE ALARM. <br /> 120 M (E) ROOF FAN 120 M (E) ROOF FAN <br /> / /BDD / /BDD <br /> M 120V REFERENCE DRAWINGS <br /> 1. FOR EXISTING VENTILATION EQUIPMENT SEE RECORD <br /> FIT _ FIT (E) WALL FAN DRAWING 40-09-iM10, JOB NO. W4573302, DATED <br /> ------------- �— 09/30 2016. <br /> TO (E) BMS TO (E) BMS �2 „�1,500 CFM <br /> CONTROLLER CONTROLLER 2. HAZARDOUS LOCATION CLASSIFICATION: UNCLASSIFIED <br /> AREA. SEE DRAWING 40-009-A3. <br /> ------------1—f FROM (E) BMS <br /> CONTROLLER <br /> (E) 10 a (E) 10 a I �\ E3::J NO I 2"-SAN-CPVC2 TO (E) <br /> BYPASS <br /> �� GO -T CANNEL A <br /> (� m <br /> FIT G GO <br /> TO (E) BMS 13/ <br /> CONTROLLER <br /> FC <br /> 625 CFM OSA METERING VAULT STATION - N—625 CFM OSA FROM (E) SVS 1 1 1/2"-(E) DRAIN <br /> (E) LOUVER ABOVE GROUND (E) LOUVER M 120/1V <br /> INTEGRAL FLOAT SWITCH <br /> 0 <br /> 625 CFM OSA�► N-625 CFM OSA (E) SUMP <br /> - <br /> (E) LOUVER w (E) LOUVER <br /> — — — — — — — — — — — — — — — — — <br /> P-1 <br /> (E) EXHAUST HOOD— — (E) EXHAUST HOOD SUMP PUMP SCHEMATIC <br /> SCALE: NONE <br /> 500 CFM 500 CFM <br /> METERING VAULT STATION <br /> BELOW GROUND <br /> 1,500 CFM <br /> y <br /> HVAC SCHEMATIC <br /> SCALE: NONE <br /> A <br /> 90% REVIEW Kennedy/Jenks Consultants <br /> 0/1.w 1 ./1 r 32001 32nd Avenue South,Suite 101 <br /> L -I L�M,,/ Federal Way,WA 98001 <br /> Ph.253-835-6400 <br /> Fax 253-952-3435 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE �-Iq P hj ACCEPTABILITY B. HOFFER 02.11.25 DRAWN DATE SUBTITLE CURREM C2381$5 EVISION SYMBOL DATE DATE 02.11.25 <br /> ORIG 100%FINAL DESIGN —ISSUED FOR CONSTRUCTION C238185 KJ RPR 09.25.23 4� '9f. THIS DESIGN AND/OR HVAC AND PLUMBING DIAGRAMS AND SCHEDULE <br /> SPECIFICATION IS APPROVED B.G. DOCKTOR 02.11.25 SHEET <br /> A SEWER METER BYPASS(PHASE 1) C238185 KJ RPR 02.11.25 DE <br /> BOE/A/G® PROVED BY PT. DATE V. RANDELOVIC 02.11.25 �� M 5 0 1 <br /> A <br /> CHECK <br /> M.SPAED <br /> UR 02.11.25 BUILDING 40-09 JOB NO. C238185 COMP NO. <br /> 'A� 42�oB APPROVED <br /> O<1A1. APPROVED MECHANICAL MASTER COL. X—X/X—X EVERETT. WA DWG NO. 40-009—M501 <br />