L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 03/05/2025 <br /> CABLE TO TRANSMITTER ...... <br /> ELECTRICAL CONDUIT <br /> CONNECTOR WITH GROMMET <br /> NOTES: ° 3" SOCx1/12" FTP BUSHING <br /> 1. THE ELECTRODE MUST BE COMPLETELY SUBMERGED IN pH PROBE ASSEMBLY ------- - - I -------qL PIPE ..° <br /> THE PROCESS LIQUID TO ENSURE PROPER MEASUREMENT. 2 3" SOC BULKHEAD <br /> 2. MAINTENANCE LOOP SHALL INCLUDE 33FT LENGTH OF M503 M503 <br /> CABLE SECURED WITH PVC-COATED SS TIE WRAPS, BEND 0 j _0 ' FLANGE SUPPORT q °. <br /> RADIUS NO LESS THAN 8". -� 3" SCH 80 PVC PIPE <br /> ° <br /> 3. MAX CABLE LENGTH: 50FT OR PER MANE. SPECIFICATION. <br /> 4. RETRACTION ASSEMBLY COMPONENTS SIZED TO <br /> ACCOMMODATE SENSOR DIAMETER. <br /> ° <br /> PIPE ADJUSTER ° d <br /> 4 <br /> 3" THREAD-O-LET I ° <br /> TO TRANSMITTER <br /> 4 <br /> STAND � ; 4 TACK WELDS 4 ° <br /> AT 99 °. <br /> d.. <br /> 4 <br /> ANCHOR BOLTS WITH ° <br /> 11" 1'-4° 11 1/2' FLANGE <br /> 1" GROUT LOCK WASHERS, DOUBLE ° 4 4 <br /> NUT AT SLAB <br /> 10" SAN SS FLOOR I I <br /> CABLE <br /> 3"THREAD- LET <br /> 3" DRAIN PORT <br /> 3'-2 1/2" <br /> H PHOBE MOUNTING DETAIL <br /> SCALE: 1 1/2" = 1'-0" M502 M563 NOTES: - <br /> 1. ALL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION. <br /> 2. WHERE USED IN CORROSIVE AREAS, SUPPORT SHALL BE CONSTRUCTED OF TYPE 316 <br /> STAINLESS STEEL MATERIALS. NEW pH PROBE <br /> 3. SUPPORT SPACING SHALL NOT EXCEED 8-0" OC (TEMPORARY LOCATION) <br /> 4. ANCHORS SHALL BE PLACED AT EACH OF FOUR CORNERS OF BASE PLATE. ANCHORS <br /> SHALL BE ASTM A193, GRADE B7 SIZE AND EMBED, ANCHORED WITH HILTI RE-50OV3 <br /> EPDXY OR APPROVED EQUAL. 3" 22.5' ELL <br /> a. IE. 366.05 <br /> PIPE SUPPORT DETAIL <br /> SCALE: NONE M502 1;0 ° ° 44 <br /> M503 ° <br /> a' <br /> CABLE (33 FEET) ° d. ° (E) SUMP <br /> PIPE STRAP ''4 d <br /> CABLE BUSHING <br /> POLYPROPYLENE 4 ° <br /> d <br /> 1 1/2'k1" FPT 1" PROCESS CONNECTOR --- -- I - - ---�PIPE <br /> REDUCING COUPLING W/ EPDM O-RING <br /> (VENDOR PROVIDED) <br /> 1 1/2" MPT CLOSE NIPPLE NUT, BOLT, r SUPPORT SADDLE AND WASHER SET OPEN CHANNEL BYPASS H PROBE rj I I <br /> THRU BOLT AND NUT SCALE: NONE OM110 M503 <br /> I I <br /> 1 1/2" FPT BALL VALVE RETRACTABLE ASSEMBLY PIPE ADJUSTER <br /> (VENDOR PROVIDED) _ <br /> _ TRANSMITTER <br /> 1 1/2" MPT CLOSE NIPPLE I (MOUNTED LOCALLY) <br /> I I <br /> 3" MPT x 1 1/2" FPT BUSHING LENGTH OF LIQUID-TIGHT <br /> I 4 TACK WELDS <br /> FLEXIBLE METAL CONDUIT <br /> 1.0 O.D. HOUSING STAND ---� AT 90' 120 VAC POWER AS REQUIRED TO ALLOW <br /> HOUSING 4-20 mA OUTPUT EASY REMOVAL OF SENSOR <br /> MOBUS RTU OUTPUT PIPE AS SHOWN <br /> A B C ANCHOR BOLTS WITH ON PLANS <br /> < INCH INCH INCH OPTION 1" GROUT LOCK WASHERS, DOUBLE <br /> U 21.60 12.90 22.27 21 NUT AT SLAB <br /> FLOOR I I - - - <br /> m <br /> I • I <br /> NOTES: <br /> 1. CONTRACTOR TO CONFIRM THAT PIPE RUN IS FIVE STRAIGHT <br /> NOTES: PIPE DIAMETERS UPSTREAM AND THREE PIPE DIAMETERS <br /> 1. ALL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION. DOWNSTREAM. <br /> 2. WHERE USED IN CORROSIVE AREAS, SUPPORT SHALL BE CONSTRUCTED OF TYPE 316 2. PROVIDE GROUNDING RINGS AND GROUND CONNECTIONS AS <br /> STAINLESS STEEL MATERIALS. REQUIRED. <br /> 3. SUPPORT SPACING SHALL NOT EXCEED 8-0" OC 3. 120VAC POWER TO TRANSMITTER AND 4-20 mA AND MODBUS <br /> 4. ANCHORS SHALL BE PLACED AT EACH OF FOUR CORNERS OF BASE PLATE. ANCHORS RTU OUTPUT SIGNAL SHALL BE ROUTED THROUGH SEPARATES <br /> SHALL BE ASTM A193, GRADE 87 SIZE AND EMBED, ANCHORED WITH HILTI RE-50OV3 JUNCTION BOXES. <br /> EPDXY OR APPROVED EQUAL. <br /> 1.13 O.D. RETRACTION PIPE NONE M50 M503 <br /> SUPPORT DETAIL 2 FLOW METER AND TRANSMITTER DETAIL s <br /> ao STOP COLLAR SCALE: NONE OM110 M503 <br /> ELECTRODE HOUSING <br /> pH/ORP ELECTRODE <br /> H PHOBE DETAIL 2 =02. 11 .215 <br /> EW Kennedy/Jenks Consultants <br /> SCALE: 3" = 1'-0" MM M503 <br /> 32001 32nd Avenue South,Suite 100 <br /> Federal Way,WA 98001 <br /> Ph.253-835-6400 <br /> Fax 253.952.3435 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LITY B.A OFFER 02.11.25 SUBTITLE CURRENr REVISION SYMBOL DATE <br /> ORIG 100%FINAL DESIGN-ISSUED FOR CONSTRUCTION C238185 KJ JEA 09.25.23 ����yERICg���� THIS AND/OR R B.GHDOCKTOR 02.11.25 MISC.STANDARD DETAILS 1 SHEEr C238185 A 02.11.25 <br /> A SEWER METER BYPASS(PHASE 1) C238185 KJ JEA 02.11.25 SPECIFICATION IS APPROVED <br /> BOE//VG® z APPROVED BY DFPi' I DATE J.ANDERSON 02.11.25 M503 <br /> CHECKED <br /> M.SPAUR 02.11.25 BUILDING 40-09 JOB NO. COMP NO. <br /> AP 55 3 PROVED C238185 <br /> ONAL APPROVED MECHANICAL MASTER COL. X-X/X-X EVERETT. WA "No. 40-009-M503 <br />