Laserfiche WebLink
AMC <br /> SHEET NOTES: Lin BENG-HEAEStO-ucal pn1 <br /> PLUMBING-HEATING•SERVICE <br /> OEXISTING UNDERGROUND GREASE INTERECEPTOR TO REMAIN.(1) 15820 AMBAUM BLVD SE <br /> $4(E)&FD-1(E)ROUTED THROUGH INTERCEPTOR.NO BURIEN,WA 98116 <br /> MODIFICATIONS OR CHANGES REQUIRED. <br /> OEXISTING FLOOR DRAIN TO REMAIN.DISCHARGE ROUTED THROUGH <br /> GT-1(E). <br /> / O EXISTING HAND SINK TO REMAIN.DISCHARGE ROUTED THROUGH <br /> O O O GT 1(E) <br /> Fill GT-1(E). <br /> O EXISTING VEGETABLE PREP SINK TO REMAIN. <br /> Ml(E) 11_ <br /> APPROXIMATE <br /> POC TO <br /> FIELD ED VERIFY VERIFY <br /> NEW DFU LOADING <br /> (/ 1� DOESN'T EXCEED EXISTING DFU LOADING. <br /> Jr <br /> \ ` O APPROXIMATED LOCATION. <br /> EXISTING SANITARY VENT.FIELD VERIFY <br /> j9 EXACT SIZE AND LOCATION.FIELD VERIFY NEW DFU LOADING <br /> 2"VENT T 2"VFNF ,F DOESNT EXCEED EXISTING DFU LOADING. <br /> 2"VENT 2"VENT 2"VENT 20FU 80FD \\ O <br /> 16DFU 8DFU 2DFU \ <br /> C - - - - - - - - - - 2"VENT T 6pF�T <br /> �!C - - <br /> S-2(E) 6DFU w <br /> O GT2 <br /> ° L"VENT ❑ <br /> 2"SAN �\ 2"SAN 2"SAN 8DFU <br /> 8DFU bFU "DFU S-1(E) <br /> I I II <br /> FFo]E[ <br /> O ® s-a(E) I m <br /> P <br /> S-1(E) S-2(E) Oa <br /> SA <br /> P-1.1 <br /> OFDA(E) "Sq <br /> 0 80F GT-2 Z <br /> O <br /> ® a <br /> tr <br /> w <br /> Z <br /> 0 <br /> 's > <br /> DFfti\ O � <br /> \� 5 <br /> n PLUMBING PLAN <br /> n Plumbing Isometric View <br /> w <br /> IY <br /> SUBJECT TO FIELD <br /> INSPECTION <br /> 2"VENT 2"VENT 2"VENT <br /> O 16DFU 8DFU 2DFU <br /> GREASE INTERCEPTOR CALCULATIONS Quote:l FX3X7F8 <br /> Reference No.75612 Project Name:RALIBERTO'S TACO SHOP <br /> :Tffl�l Step 1:Flow rate to grease interceptor <br /> SPECIFICATIONS Fixture flow rate:(cu in/231)=gai x 0.7512 min=2 min flow rate <br /> Notes: NAME 'I '. OTV CU IN FLOW RATE <br /> 1 4"FPT metloutlet with 3"and 4"plain end things. 35' S Compartment Sink 3 Compartment Sink 18"x 18"x 10"(3) 9,720 15.78 GPM <br /> 2. Unit weight-49Ibs.temperaAvetweture: <br /> 2161bs.) �127/16" Floor Sink Floor Sink N/A 1 N/A 1GPM <br /> 3. Maximum operating temperature: (OutletOptional) <br /> al) <br /> 150"F continuous (optlonal) Total 16.78 GPM <br /> 4. Capacities-Liquid:20 gal. <br /> 2"VENT 2"VENT Grease:1301bs.(17.8 gal.)@35 GPM <br /> 1 1� 2DFU _T I Grease:1271bs.(17.3 gal.)@50 GPM °o°o°O°o°o< O°o°o°o° Flow rate used to size interceptor(less of fixture or pipe size) <br /> 2"VENT 6DFU Grease(99%-at least 2 units in ser es):18011-(24.7 gal.) o 0 0 o a o a o 0 <br /> I� 1 1 @35 GPM °o°00000 00000000o Pipe size o in): <br /> 8DFU Soli de:l.8gal. A °-- - °o°O°o° A Pipe Size Now rate perManning'sFormula 10 GPM <br /> s. Buln-iniowcomml. °o°a°oo 0000000 <br /> I, Forgravity drainage applications only. °O°O°O O°O°O° step 2:Grease Production <br /> 7. Do not use for pressure applications. O O O O O O <br /> Inlet Servin p y p p p 8. Cover placement allows full access to tank for �ODODO° �O�o�00 outlet'B" I I gs par dsyx Grease roduction,value x Days um routs=Grease Output <br /> proper maintenance. O o 0 O O O 0 list En Servings per day:75 O <br /> 9. Vent not required unless per local tittle. °O°O°O°O O°O°O°O° Outlet Foot g P y <br /> 10,Engineered inlet and outlet diffusers are o 0 0 0 0 0 0 0 0 0 <br /> govable o a o 0 o s o 0 0 o Must Face This �" Grease production value:0.0351bs per serving(Mexican:High/No flatware) <br /> ovable to ins ecgdean o 0 0 0 0♦ o 0 0 0 o Days between pumpouts:45 days <br /> p piping. O O O O O o 0 0 0 0 0 0 Direction In All <br /> 11.Integral air relief/anti-siphon. °::a::e. .: :-°.: Configurations <br /> 12.Designed for indoor,on-0oor,below-grade or low-profile 75 x 0.035 x 45.118.125I s of FOG <br /> nder sink installations. outlet"C" <br /> ENGINEER SPECIFICATION GUIDE (Optional) r r Description:GREASE INTERCEPTOR 35 GPM/50 GPM,4"FPT ^ <br /> Schier Great Basin^^grease interceptor model#GB2 CONNECTIONS W/3"AND 4"PLAIN END v, <br /> hall be bfebme guaranteed and made In USA of TOP VIEW ISOMETRIC VIEW ADAPTERS,PEDESTRIAN RATED POLYPROPYLENE <br /> mless,rotationally-moltletl polyethylene with minimum (COVER REMOVED FOR CLARITY) COVER <br /> 5/16"hedfor wall thickness.Interceptor shall be O <br /> furnished for above or below grade installation. Dimensions:Length:35',Width:23',Height:13.75' <br /> Interceptor shall be cedified to ASME At 12.14.3(type C) Flow Rate/Grease Capacity:35 GPM/130 Ibs <br /> and CSA B481.1,with field cut riser system,built-in flow <br /> convoland three outlet options.Interceptor flow rate shall Liquid Capacity:20 gal <br /> be 35 ar 50 GPM.Interceptor grease capacity shall be Flow Control V <br /> 0 0 0 0 130 lbs.@ 35 GPM or 1271be.@ 50 GPM.Cover shall ❑21-112"Cover w <br /> provide water/gastight seal and have minimum 4501bs. tLof4 FPT 23" CV <br /> load capacity. Inlet and E l Be.Note p11 <br /> Specification Note:This Great Basin model has been sized to the flow rate and grease production requirements of the Q 06 <br /> CERTIFIED PERFORMANCE 5" application and may not be subatitonedbyliquid capacity atom.Any substitution requests must be approved by the <br /> S-1 E S-2 E Great Basin'"hydromechanlcal grease Interceptors and authori Navin <br /> () () are third party performance-tested and listed by I I I I specifying engineer an ry gjurisdlction. a <br /> 1T IAPMO to ASME#At 12.14.3 and CSA B481.1 13-314" Please contact support@schierproducts.coin for technical and procurement support for the specified Great Basin m <br /> grease interceptor standards and greatly exceed J <br /> 1 1/2"SAN 1 1/2"SAN requirements for grease separation and storage. 8-314" 1-314" model. //� O <br /> They are campliaotto the Uniform Plumbing Code. INVERT v J <br /> GT 1 the National Standard Plumbing Code,the National <br /> Plumbing Code of Canada,and the International V 1�1 <br /> Plumbing Code. Engineered Inlet and SOutlet Diffuserstatic Water Line O W�/ <br /> O Satisfies ilemiD Meer- <br /> er-Proucy requIaxrwmx,,po "man ata-d SECTION A-A END VIEW M Uj <br /> 2"SAN 2"SAN uIl,Ad.nsalladinserias.ProdualabNsarepemanenuyanamea C\I > <br /> m mslaa and nawae of amlro....vmawm9. CV <br /> 8DFU 2DFU <br /> O 2"SAN MODEL NUMBER: PART NUMBER: 4065-001-05 w s••� <br /> 8DFU GB2 DESCRIPTION: <br /> G L GB2 GREASE INTERCEPTOR 35 GPM/50 GPM,4"FPT INLET/OUTLET,WITH UP O U P O 6455 Woodland Dr Uj <br /> 3"AND 4"PLAIN END FITTING ADAPTERS AND PEDESTRIAN RATED COVER Shawn Teee 13-951.,KS 6621833 M <br /> X913 <br /> :999 <br /> s W <br /> ® C ® c : 41uc s cam h'erprod t. <br /> DWG BY: C.SINCLAIR DATE: 5/52022 REV: - ECO: <br /> 3 West Wash Line Elevation o PSCHIER GB-2 o GREASE INTERCEPTOR CALCULATION <br /> 3/4";1'-0" NTS GREASE <br /> < <br /> FIXTURE SCHEDULE <br /> FIXTURE TRIM CONNECTION <br /> TAG LOCATION QUANTITY MANUFACTURER& MANUFACTURER& MANUFACTURER& DESCRIPTION COLD HOT REMARKS <br /> TYPE MODELNUMBER TYPE MODELNUMBER TYPE MODELNUMBER WATER <br /> WASTE VENT TRAP WATER <br /> S-1(E) KITCHEN 1 3 COMPARTMENT SINK EXISTING FAUCET EXISTING 6DFU SDFU 2 3 3 <br /> WSFU WSFU <br /> 1/2" 1/2" <br /> S-2(E) KITCHEN 1 PREP SINK(MEAT) EXISTING FAUCET EXISTING 1 1 z <br /> WSFU WSFU p <br /> 1/2" 1/2" di <br /> d v <br /> S-3(E) KITCHEN PREP SINK(VEG) EXISTING FAUCET EXISTING 1.5 1.5 z O <br /> WSFU WSFU <br /> F- F- <br /> W W <br /> 2" 1-1/2" .1/5 .5 O O <br /> 1/ <br /> S-4(E) KITCHEN 2 HAND SINK EXISTING FAUCET EXISTING 2DFU 2DFU 2" WSFU WSFU a a <br /> MS-1(E) KITCHE 1 MOP SINK EXISTING FAUCET EXISTING 2 1-1/2 2„ 13 13 <br /> 3DFU 3DFU WSFU WSFU DATE: 03/01/2025 <br /> SCALE: As indicated <br /> GREASE INTERCEPTOR SHEET SIZE: H'RIS " <br /> DRAWN BY: CHRIS CLEMENS <br /> E1ndirec:tco:n:n:ection required for 3 compartment CAPACITY CLEMECD986N1 <br /> TAG BASIS OF DESIGN MANUFACTURER&MODEL REMARKS CHECKED BY: INSPECTOR <br /> FLOW RATE(GPM) GREASE LBS SOILD CAP. LIQUID CAP. <br /> JOB NO. <br /> GT-1(E) EXISTING <br /> GT-2 SCHIER GB-2 35GPM 130 LBS 1.8 GAL 20 GAL PERMIT <br /> DRAWINGS <br /> SHEET NAME: <br /> PIPE MATERIAL SITE PLAN & <br /> SITE <br /> PLAN <br /> PIPING IDENTIFICATION BUILDING SYSTEM MATERIAL REMARKS AREA#: REV. <br /> SAN&VENT SANITARY WASTE&VENT SCH 40 PVC SCH 40 PVC DWV Pipe and Drainage Fittings with Solvent Weld Joints to be in Accordance with Section 705.6.2 of the 2018 Uniform Plumbing Code(UPC)and ASTM F656 for Primer& PROJ.#: a <br /> ASTM D2564 for Solvent Cement. <br /> CW&HW DOMESTIC COLD,&HOT COPPER Type L Copper Tubing Shall Conform to ASTM B 88.Copper Mechanical Press Fittings Shall Conform to NSF 61G&IAPMO PS117.Pex-A Tubing Shall Conform to ASTM 876&877. DRAWING No. <br /> Pex-A Fitting Shall Conform with ASTM F876 <br /> P-1.1 <br />