fluctuating water levels in a flow control BMP can decrease the effective treatment flow rate of an <br /> upstream runoff treatment BMP by altering the available hydraulic drop across the BMP. <br /> The maintenance and operation information for the stormwater facilities must be provided in a <br /> separate document entitled "Maintenance and Operations Manual",and must include a first page <br /> indicating the party responsible for maintenance and operation. In addition,the following language <br /> shall also be included in both the M&O manual and the drainage report: A copy of the maintenance <br /> and operations manual shall be retained on-site or within reasonable access to the site and shall be <br /> transferred with the property to any new owner. A log of maintenance activities that indicate what <br /> actions were taken shall be kept and available for inspection by the City of Everett upon request. <br /> Lack of additional comment on the preliminary Stormwater Site Plan submitted with the application <br /> does not indicate approval of any portion of the Stormwater Site Plan. <br /> 10. Special charges for connection to the sewer and water systems in accordance with Ordinance 3095-08 <br /> (codified as EMC 14.08.13S)and subsequent revision are applicable. These charges are based on projected <br /> water usage and can be substantial. Applicant is encouraged to obtain a copy of the Ordinance and <br /> determine estimated charges priorto building permit application. The actual charges shall be computed by <br /> the Public Works Department per the ordinance in effect at the time and according to the information on <br /> the approved plans at the time of building permit issuance. <br /> 11. A DCDA is required on the fire service,and shall be located in a vault outside of the building if the <br /> connection from the main to the building is greater than 70ft,or located in the sprinkler riser room if within <br /> 70'of the connection to the main_ <br /> 12. A DCVA is required on the irrigation service and shall be located in an underground vault. <br /> 13. All fire hydrants shall be no closer than 50'to the building and no further than 200'from the building.See <br /> Fire Department comments for additional requirements. <br /> 14. The City's Water Department will do the connections to the existing water main after purity testing at the <br /> owner's expense. Each connection will be a separate utility permit based on a custom cost estimate <br /> calculated by the Water Department and sent to the applicant team.These permits are automatically <br /> generated during Public Works permit review,so coordination is not needed during permit review by the <br /> applicant team,other than putting notes on the plans reflecting the above listed information.Coordination <br /> between the contractor and the Water Department will need to take place during construction to schedule <br /> the water crews 3-4 weeks in advance. For plan notes: Contact Jim Spooner in the Water Department at <br /> 425-257-8827 or JSpoonerc@everettwa.Qov). <br /> 15. For the water main installation, current City Standards (Chapter 5 Specifications and 500 Series Drawings) <br /> must be followed. https:lleverettwa.gov/1531/Design-Construction-Standards <br /> 16. Use 45 degree bends instead of 90 degree bends and use MegaLug restraints or equal on all MJ's. <br /> 17. All fire lines must have restrained joints, MegaLug or equal, and field lacks. <br /> Page 8of13 <br /> Project No.SEPA18-021 <br /> EVERETT <br />