Laserfiche WebLink
7'-6"6'-0"6'-6"5'-8" <br />INSTRUMENTATION & CONTROL <br />PLC PANEL LAYOUT DRAWING <br />Y-00-4001 <br />487 <br />C. BLIESNER <br />D. JACKSON <br />L. LUBKE <br />Designed <br />ACTION APRVDDATE <br />Drawn <br />Checked <br />REVISIONDATENO.APRVD <br />PLANS ISSUED FOR 3200 Cedar Street <br />Everett, WA 98201 <br />425.257.8800 everettwa.gov <br />PORT GARDNER <br />STORAGE FACILITY - <br />FACILITY CONSTRUCTION PACKAGE <br />WO# UP-3525 <br />ACTION APRVDDATE ACTION APRVDDATE <br />BID CONST <br />Design Review Level <br />500RECORD <br />Of Total <br />Sheet No. <br />Drawing <br />PATH/FILENAME: C:\Users\DJackson\AppData\Local\Autodesk\AutoCAD Plant 3D\CollaborationCache\97190 - Port Gardener\PID DWG\Y-00-4001.dwgLAST UPDATE: August 14, 2025 @ 11:58:58 amPLOT DATE: August 14, 2025 @ 12:14:26 pm12/2/2024 ZB 09/03/2025 ZB <br />1 2 3 40SLOT:5CPU <br />SCS-PG-70-PLC-7000 <br />PLC RACK 00 LAYOUTDISCRETE INPUT16-CHANNELCPUDISCRETE INPUT16-CHANNELDISCRETE INPUT16-CHANNELDISCRETE INPUT16-CHANNEL2 3 4 51SLOT:60 <br />SCS-PG-70-PLC-7000 <br />RIO RACK 01 LAYOUTETHERNET BASECONTROLLER MODULE7CPU <br />DISCRETE OUTPUT8-CHANNELDISCRETE OUTPUT8-CHANNELDISCRETE OUTPUT8-CHANNELDISCRETE OUTPUT8-CHANNELANALOG INPUT/OUTPUT8-CHANNEL/4-CHANNELNPX <br />PLC/RIO BILL OF MATERIALS <br />ITEM NO.DESCRIPTION QUANTITY <br />1 DL205 BASE UNIT 2 <br />2 DO MORE H2 CPU 1 <br />3 NOT USED N/A <br />4 NOT USED N/A <br />5 ETHERNET BASE CONTROLLER MODULE 1 <br />6 16 CHANNEL DIGITAL INPUT MODULE 7 <br />7 8 CHANNEL DIGITAL OUTPUT MODULE 5 <br />8 8 CHANNEL/4 CHANNEL ANALOG <br />INPUT/OUTPUT MODULE 2 <br />9 NOT USED N/A <br />10 12" OPERATOR INTERFACE TERMINAL 1 <br />PANEL BILL OF MATERIALS <br />ITEM NO.DESCRIPTION QUANTITY <br />11 NEMA 12 ENCLOSURE 1 <br />12 BACK PANEL 1 <br />13 SURGE PROTECTION DEVICE A/R <br />14 CONTROL RELAY A/R <br />15 PANEL LIGHT 1 <br />16 THERMOSTAT 1 <br />17 HEATER 1 <br />18 120 VAC RECEPTACLE 1 <br />19 24 VDC POWER SUPPLY 1 <br />20 24 VDC UPS 1 <br />21 24 VDC UPS BATTERY 1 <br />22 DC TO DC CONVERTER, NEC CLASS 2 <br />OUTPUT A/R <br />23 MANAGED NETWORK SWITCH 2 <br />24 CIRCUIT BREAKER A/R <br />25 TERMINAL BLOCK A/R <br />26 FUSED TERMINAL BLOCK A/R <br />27 GROUND BAR A/R <br />28 WIREWAY (SIZE AS REQUIRED)A/R <br />29 DIN RAIL, 35 MM A/R <br />30 NEMA 12 EXHAUST FAN 1 <br />31 NEMA 12 LOUVER 1 <br />32 ENCLOSURE DOOR SWITCH 2 <br />33 DO MORE H2 PLC KEY NOTE 1 <br />NAMEPLATE SCHEDULE <br />NPX LINE 1 LINE 2 LINE 3 <br />NP1 SCS-PG-70-PNL-7000 OMES BUILDING PLC PANEL <br />DISCRETE INPUT16-CHANNELDISCRETE INPUT16-CHANNEL6 7 <br />TYP <br />TYP <br />DISCRETE OUTPUT8-CHANNELTYP <br />SCALE: NTS <br />A ENCLOSURE EXTERIOR <br />SCALE: NTS <br />B BACK PANEL LAYOUT <br />RACK 00 RACK 01 <br />GENERAL NOTES <br />KEYNOTES <br />1.THIS DRAWING IS GENERAL IN NATURE AND DEPICTS <br />GENERAL PANEL LAYOUT AND FABRICATION <br />REQUIREMENTS FOR THE APPLICABLE CONTROL PANEL. <br />FABRICATE PANEL IN ACCORDANCE WITH SECTIONS 40 67 00 <br />AND 40 63 43. <br />2.CONTROL PANEL SHALL MEET THE REQUIREMENTS OF UL <br />508A. <br />1 BILL OF MATERIALS LISTS MAIN PLC/RIO COMPONENTS <br />FOR TYPICAL PANEL. REFER TO SECTION 40 63 43 FOR <br />DETAILS AND ACCESSORIES <br />2 UPS BATTERIES TO BE PHYSICALLY SECURED TO PANEL <br />WHILE STILL ALLOWING ACCESS/REMOVAL FOR <br />MAINTENANCE <br />3 COORDINATE COOLING FAN AND LOUVER LOCATION ON <br />PANEL WITH PANEL INSTALLATION LOCATION TO PREVENT <br />BLOCKING BY ADJACENT PANELS <br />15 <br />11 <br />10 <br />17 <br />21 <br />32 <br />16 <br />14 <br />24 <br />13 <br />29 <br />30 <br />18 <br />25 <br />27 <br />33 <br />27 <br />25 <br />26 <br />25 <br />31 <br />28 <br />19 <br />12 <br />22 <br />20 <br />29 <br />27 <br />23 <br />26 <br />13 <br />25 <br />14 <br />27 <br />2 6 6 6 6 6 6 5 7 7 7 7 7 8 <br />1 <br />2 <br />3 <br />3 <br />BASE UNIT1 <br />DISCRETE INPUT16-CHANNELSPARE6 <br />BASE UNIT1 <br />ANALOG INPUT/OUTPUT8-CHANNEL/4-CHANNELSPARE8