Laserfiche WebLink
INSTRUMENTATION & CONTROL <br />TYPICAL RIO PANEL POWER <br />DISTRIBUTION CONNECTION <br />DIAGRAM <br />Y-00-4004 <br />490 <br />C. BLIESNER <br />D. JACKSON <br />L. LUBKE <br />Designed <br />ACTION APRVDDATE <br />Drawn <br />Checked <br />REVISIONDATENO.APRVD <br />PLANS ISSUED FOR 3200 Cedar Street <br />Everett, WA 98201 <br />425.257.8800 everettwa.gov <br />PORT GARDNER <br />STORAGE FACILITY - <br />FACILITY CONSTRUCTION PACKAGE <br />WO# UP-3525 <br />ACTION APRVDDATE ACTION APRVDDATE <br />BID CONST <br />Design Review Level <br />500RECORD <br />Of Total <br />Sheet No. <br />Drawing <br />PATH/FILENAME: C:\Users\DJackson\AppData\Local\Autodesk\AutoCAD Plant 3D\CollaborationCache\97190 - Port Gardener\PID DWG\Y-00-4004.dwgLAST UPDATE: August 14, 2025 @ 12:55:22 pmPLOT DATE: August 14, 2025 @ 12:57:40 pm12/2/2024 ZB 09/03/2025 ZB <br />CB-X <br />L N <br />G <br />20A <br />CB-X <br />CB-X <br />HEATER <br />L <br />120 VAC <br />FROM POWER DISTRIBUTION PANEL <br />N G <br />AC POWER <br />AVAILABLE <br />HEATER <br />L N <br />G <br />PANEL LIGHT <br />WITH SWITCH <br />NXX <br />NXX <br />NXX <br />CB-X <br />NXX <br /> <br />F COOLING FAN <br />CB-X <br />NXX SPARE <br /> <br />CR <br />XX <br />SPD <br />3A <br />CB-X <br />120 VAC RECEPTACLENXX <br />CB-X L <br />G <br />24 VDC <br />POWER <br />SUPPLY <br />N <br />-+ <br />NXX <br />24 VDC UPS <br />-+ <br />-+ <br />-+ <br />24 VDC UPS <br />BATTERY <br />-+ <br />+- <br />OPERATOR <br />INTERFACE <br />TERMINAL <br />+- <br />G <br />+- <br />NETWORK <br />SWITCH <br />FUXX <br />XXA <br />FUXX <br />XXA <br />24V- <br />24V- <br />OIT <br />RIO PANEL <br />NETWORK <br />SWITCH <br />+- <br />IN-24 VDC <br />FUXX <br />XXA <br />24V-24 VDC NEC CLASS 2 <br />OUTPUT <br />OUT-24 VDC+- <br />24 VDC UPS <br />CONTINUED <br />TOP RIGHT+- <br />MODBUS <br />TCP/IP <br />GATEWAY <br />MODBUS <br />TCP/IP <br />GATEWAY <br />+- <br />RACK 00 <br />BASE UNIT <br />DISCRETE INPUT MODULES <br />SEE DWG Y-00-5005 <br />FUXX <br />XXA <br />FUXX <br />XXA <br />FUXX <br />XXA <br />FUXX <br />XXA <br />FUXX <br />XXA <br />24V- <br />24V- <br />24V- <br />24V- <br />24V- <br />FUXX <br />XXA <br />24V- <br />INTRINSIC SAFETY <br />PANEL <br />RACK 00 <br />POWER <br />DISCRETE INPUT <br />MODULES <br />FUXX <br />XXA <br />24V- <br />+- <br />24 VDC UPS <br />FROM BELOW <br />LEFT <br />+- <br />RACK 01 <br />BASE UNIT <br />FUXX <br />XXA <br />24V- <br />RACK 01 <br />POWER <br />DISCRETE OUTPUT MODULES <br />SEE DWG Y-00-5005 DISCRETE OUTPUT <br />MODULES <br />ANALOG <br />INPUT/OUTPUT <br />MODULES <br />SPARE <br />FUXX <br />XXA <br />24V-SPARE <br />+- <br />SPARE <br />FUXX <br />XXA <br />24V- <br />TO GAS <br />SAMPLING <br />MODULES <br />SEE DWG Y-00-5006 <br />TO INTRINSIC <br />SAFETY PANEL <br />SEE DWG Y-00-4009/10 <br />FUXX <br />XXA <br />24V- <br />GENERAL NOTES <br />KEYNOTES <br />1.THIS DRAWING IS GENERAL IN NATURE AND DEPICTS <br />GENERAL POWER DISTRIBUTION FOR THE APPLICABLE <br />CONTROL PANEL. FABRICATE PANEL IN ACCORDANCE WITH <br />SECTION 40 67 00. <br />2.PROVIDE EXTERNAL WIRE NUMBERS PER SECTION 26 05 00. <br />PROVIDE INTERNAL WIRE NUMBERS PER SECTION 40 67 00. <br />3.ON THE POWER DISTRIBUTION DRAWING(S), PROVIDE EACH <br />CIRCUIT BREAKER (CB) AND FUSE (FU) WITH A UNIQUE ID <br />NUMBER AND IDENTIFY AN AMP RATING, IF NOT SHOWN. <br />4.POWER DISTRIBUTION WIRING SHOWN AS TYPICAL FOR <br />EACH TYPE OF I/O MODULE. PROVIDE I/O MODULES <br />ACCORDING TO RACK LAYOUT FOR EACH RIO PANEL SHOWN <br />ON Y-00-4003. <br />1 REFER TO ELECTRICAL DRAWINGS FOR RIO PANEL 120 <br />VAC POWER SOURCE <br />2 PROVIDE NEC CLASS 2 POWER SUPPLY WHEN REQUIRED <br />BY PRODUCT MANUFACTURER <br />3 PROVIDE RIO RACK(S) WITH BASE UNIT, ETHERNET BASE <br />CONTROLLER AND DIGITAL AND ANALOG MODULES <br />ACCORDING TO SECTION 40 61 93A I/O SCHEDULE AND <br />RACK LAYOUTS ON DWG Y-00-4003 <br />4 PROVIDE FUSE FOR EACH I/O MODULE <br />5 PROVIDE FUSE IN SCS-PG-20-PNL-7000 FOR EACH GAS <br />SAMPLING MODULE <br />6 FOR SCS-PG-20-PNL-7000, REFER TO DWG Y-00-4010 FOR <br />DEBRIS REMOVAL INTRINSIC SAFETY PANEL POWER <br />DISTRIBUTION. FOR SCS-PG-60-PNL-7000, REFER TO DWG <br />Y-00-4009 FOR EFFLUENT PUMP STATION INTRINSIC <br />SAFETY PANEL POWER DISTRIBUTION <br />7 PROVIDE MODBUS TCP/IP GATEWAY AS REQUIRED ON <br />NETWORK DIAGRAM DWG Y-00-5001 <br />4 <br />4 <br />4 <br />3 <br />3 <br />5 <br />6 <br />2 <br />1 <br />7 <br />00 <br />05 <br />10 <br />15 <br />20 <br />25 <br />30 <br />35 <br />40 <br />45 <br />50 <br />55 <br />60 <br />65 <br />70 <br />75 <br />80 <br />85 <br />90 <br />95 <br />100 <br />110 <br />105 <br />ANALOG INPUT/OUTPUT MODULES <br />SEE DWG Y-00-5004 <br />115