My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Absher/Stellar J Joint Venture 12/8/2025 (3)
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Absher/Stellar J Joint Venture 12/8/2025 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2025 4:01:59 PM
Creation date
12/9/2025 3:59:50 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
Absher/Stellar J Joint Venture
Approval Date
12/8/2025
Council Approval Date
11/19/2025
Department
Public Works
Department Project Manager
Zach Brown
Subject / Project Title
Port Gardner Storage Facility – Facility Construction Package Addenda
Tracking Number
0005035
Total Compensation
$0.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
Addendum 3 Page 3 <br />CITY OF EVERETT ⋅ 3200 Cedar Street ⋅ Everett, WA 98201 ⋅ (425) 257-8800 ⋅ Fax (425) 257-8882 <br /> <br />“The project will install a discharge connection on the City’s Deepwater Outfall <br />to provide groundwater dewatering capacity up to 4,500 gpm at the site with <br />1,500 gpm reserved for stormwater and dewatering water originating from <br />PGSF site activities and an additional capacity of 3,000 gpm reserved for <br />dewatering water produced from the WMVD contract taking place <br />concurrently as described in Section 01 12 16. Refer to Drawing C-10-1303, <br />Enlarged Plan – A, and Key Note 33 for connection details. Refer to Section <br />31 23 19 Exhibit A for the estimated high and low pumping system curves for <br />discharge to the Deepwater Outfall.” <br />Item 8 - SPECIFICATION 31 50 00 EXCAVATION SUPPORT AND PROTECTION: <br />Add the following Paragraph J to 1.05 Design Requirements: <br />“J. Dewatering systems flow limitations may inform and limit excavation and <br />shoring design type, extents, and schedule to meet the Contract <br />requirements. All excavations opened at one time shall be coordinated and <br />limited to the combined construction dewatering discharge rates allowable <br />provided in Section 01 12 16 Exhibit A-1 and specified in Section 31 23 19 <br />DEWATERING. Discharge to Deep Water Outfall 100 shall be limited to 1,500 <br />gpm for bidding purposes.” <br />ANSWERS TO QUESTIONS SUBMITTED FOR CLARIFICATION <br /> <br />Q1 - Specification Section 09 65 19 – Resilient Tile Flooring was removed in the last <br />round of bidding (Addendum 5, Question 85), but was included in this round of bidding, <br />please confirm this specification section still does not apply to this project. <br /> <br />Resilient Tile Flooring is not in the project scope and the specification is removed <br />with Item 5 above. <br /> <br />Q2 - On Sheet A-25-4001, Keynote 1 is used to denote where plaster patching is <br />required, there is also a hatching pattern defined in the Legend which shows the same <br />thing, and says to see the individual elevations for the estimated square footage. Just to <br />clarify, the provided estimated quantities are the total square footage of plaster that <br />should be assumed, or should additional square footage be captured? <br /> <br />Keynote 1 and concrete hatching pattern cover the same area which should be <br />the basis of estimation of total area of plaster coverage. No additional area is <br />required other than what has been indicated. <br /> <br />Q3 - Keynote 1 on S-35-3002 states all the exposed steel in this area is to be <br />galvanized, but it doesn’t reference a finish coat, please clarify if all the exposed steel <br />should also be painted. <br /> <br />Exposed steel, including new and existing stairs in Area 35 and Area 50 which are <br />detailed on S-35-3002, shall be galvanized and coated with Coating System
The URL can be used to link to this page
Your browser does not support the video tag.