My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Absher/Stellar J Joint Venture 12/8/2025 (3)
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Absher/Stellar J Joint Venture 12/8/2025 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2025 4:01:59 PM
Creation date
12/9/2025 3:59:50 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
Absher/Stellar J Joint Venture
Approval Date
12/8/2025
Council Approval Date
11/19/2025
Department
Public Works
Department Project Manager
Zach Brown
Subject / Project Title
Port Gardner Storage Facility – Facility Construction Package Addenda
Tracking Number
0005035
Total Compensation
$0.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
Port Gardner Storage Facility Volume 7 Attachment O <br /> Page 19 <br />CITY OF EVERETT ⋅ 3200 Cedar Street ⋅ Everett, WA 98201 ⋅ (425) 257-8800 ⋅ Fax (425) 257-8882 <br /> <br />Q93 - Please verify if insulating flanges per Spec 40 05 06, 2.04 are required for steel <br />flanges connected to iron body valves. <br />Insulating flanges are not required when connecting steel flanges to iron-body <br />valves, as the galvanic potential between the two metals is minimal and does not <br />present a risk of galvanic corrosion. <br />Q94 - An actuated valve and gate schedule is provided under Spec 40 06 20.13, 4.01, <br />but we do not have a manual actuated valve schedule for all manual valves tagged on <br />the drawings. The valves tagged on the drawings do not indicate what type of valve is <br />to be used. <br />There is no manual valve schedule included with the package. Manual valve type <br />is indicated on the P&IDs, and specifications are refenced within the piping <br />system schedules for each valve type (40 05 02.XX). <br />Q95 - Substitution request for DURO-Last Roofing System <br />Per Section 00 72 00, Section 8.5, 1st paragraph, 2nd sentence, only the <br />Contractor may request substitutions. Per Section 01 25 00, Paragraph 1.7.C, <br />requests for substitutions will not be considered during the bid period. <br />Q96 - In specification section 08 33 00, section 2.02.B.3 calls for an operable wind load <br />rating. Cookson-Clopay’s insulated coiling door with grade 316 stainless steel does not <br />offer an operable wind load rating. Their Wind-Master rolling door does meet the 20 <br />PSF operable wind load but is only available in type 304 stainless. Should we prioritize <br />the wind load requirement with type 304 stainless, or maintain the specified grade 316 <br />stainless without the operable wind load rating? <br />If stainless steel is provided, 304 should be used to meet the wind loads. The use <br />of 304 can be noted as a deviation during the submittal review. <br />Q97 - Please advise if this project has any fire alarm, security, and/or access control <br />scope of work. <br />There is no fire alarm or access control as part of this project. Site security will be <br />handled through a 3rd party contractor, coordinated directly by the Owner. <br />Q98 - Please advise if the cable trays' CTS05, CTC015, CTP1015, CTS002, CTC002, <br />CTP1002 are existing or new. They are shown as gray on the drawings which usually <br />implies existing but on the job walk I did not see any trays <br />All cable trays shown on drawings are new and to be installed as part of this <br />project. <br />Q99 - Please advise if the panels 20-PNL-7010, 60-PNL-7010, 30-PNL-7010, 46-PNL- <br />7010 are part of the existing scada network. Please advise if any of the existing scada <br />network is shown on this page.
The URL can be used to link to this page
Your browser does not support the video tag.