Laserfiche WebLink
Port Gardner Storage Facility Volume 7 Attachment O <br /> Page 18 <br />CITY OF EVERETT ⋅ 3200 Cedar Street ⋅ Everett, WA 98201 ⋅ (425) 257-8800 ⋅ Fax (425) 257-8882 <br /> <br />Q86 - 4/A-70-4005 shows that the FRP wainscot doesn't extend the entire wall height. <br />Provide the elevations for this FRP in the janitor room of the OMES Building. <br />The FRP wainscot within Area 70, room 102 to be 4-feet high per interior finish <br />legend. <br />Q87 - Confirm ladders on Detail C,D/S-30-3020 are to be newly installed. <br />Area 30 currently has 6 existing ladders, one each in Cells 1, 2, 3, 13, 14, and 15. <br />See Drawing G-00-5002 for cell numbering scheme. Per Drawings GX-30-1001 and <br />GX-30-3001, the ladders in Cells 1, 2, and 3 are to be demolished. The ladders in <br />Cells 13, 14, and 15 are to remain. Per the line weight used on Sheet S-30-1002, <br />new ladders will be installed in Cells 1 through 12. Per Keynote 1 on Drawing S- <br />30-1002, ladders in Cells 13, 14, and 15 will be retained and modified. <br />Q88 - Confirm that SST weir plates as per Sec 2/S-30-3006 are to be installed only in <br />Cell-13 of the Primary combined sewer storage and not in Cell 14 and Cell 15 (S-30- <br />1002). <br />The weir plates shown in Section 2/S-30-3006 are to be installed in Primary <br />Storage Area 30 Cells 13, 14, and 15. <br />Q89 - Spec 11 30 13-2.02 refers to the microwave ovens. Confirm that this is owner <br />provided and installed. <br />Contractor to provide pricing for furnishing and installing microwave oven per <br />the specifications. <br />Q90 - S-70-1001 says to reinstall the existing stair after work is complete. From job walk <br />photos, it looks like the lower staircase of the platform is not existing. Confirm if a new <br />staircase is required and provide details. <br />The Owner temporarily removed the lower portion of the staircase to reduce <br />access while the facility was unoccupied. The lower portion of the staircase will <br />be provided to an on-site location at Owner’s choosing for the Contractor to <br />install. <br />Q91 - Please confirm whether the wet well floors in Area 46 require HP-6 coating. Spec <br />Section 09 90 00 indicate only walls and ceilings are coated. <br />The wet well floor in Area 46 does not require any coating. The finish schedule in <br />09 90 00 is correct; only the walls and ceiling require coating. <br />Q92 - What is the wall thickness of the pipe pile? <br />See Volume 7 Attachment B Geotechnical Engineering Report Port Gardner <br />Storage Facility May 2025, Section 4.6.