My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2523 STATE ST 2026-01-06
>
Address Records
>
STATE ST
>
2523
>
2523 STATE ST 2026-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2026 8:22:46 AM
Creation date
12/15/2025 3:14:49 PM
Metadata
Fields
Template:
Address Document
Street Name
STATE ST
Street Number
2523
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•47fA-7 <br /> flirll <br /> ICOMPANY PROJECT <br /> // Design Build Services,Inc. Julie 8 Michael Larson, <br /> O O�, A /O 28119 onroe. A 9 SE Everett Remodel- <br /> Monroe.,Y/ Monroe,WA 9659 2523 State Street,Everett,WA 98201 <br /> PH:360-193-9659 Job#22-32315 <br /> SOFtWAREFOR WOOD VfSfCm. Nov.10,202212:25 j26.wwb <br /> Design Check Calculation Sheet <br /> Wood Works Sizer 2019(Update 4) <br /> Loads: <br /> Load Type Distribution Pat- Location [ftl Magnitude Unit <br /> LO adl tern Start End Start End <br /> Dead Full UDL 30.0 plf <br /> Load2 Snow Full UDL 50.0 plf <br /> Self-wci ht Dead Full UDL 1.2 plf <br /> Maximum Reactions(lbs)and Bearing Lengths(in): <br /> 5.35V <br /> r 5.042' <br /> Unfactored• <br /> Dead 83 <br /> Snow 117 83 <br /> Factored: 127 <br /> Total 210 <br /> Bearing: _ 210 <br /> 1-1 <br /> Length 0.50. <br /> Min req'd 0.50• 0.50- <br /> "Minimum bearing lenothl setting used:1/2"for end supports 0.50- <br /> j26 1 <br /> Lumber-soft,Hem-Fir,No.2,2x4(1-1/2"x3-1/2") <br /> Supports:All-Non-wood <br /> Roof joist spaced at 24.0"c/c;Total length:5.44':Clear span(horz):5.0`,Volume=0.2 tuft.:Pitch:4112 <br /> Lateral support top=at supports,bottom=at supports;Repetitive factor.applied where permitted(refer to online help); <br /> This section PASSES the design code check. <br /> Analysis vs.Allowable Stress and Deflection using Nos 2018: <br /> Criterion Anal sis Value Desi n Value Unit Anal sis/DenO.29 <br /> Shear fv = 50 Fv' = 172 <br /> Bending(+) fb - 1030 psi fv f\r' =Fb' = 1600 psi fb/Fb' =Live Defl'n 0.12 - L/550 0.27 - L/240 in Total Defl'n 0.19 = L/332 0.35 = L/180 in <br /> Additional Data: <br /> FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC8 <br /> Fv' 150 1.15 1.00 1.00 - - - - 1.00 1.00 2 <br /> . . 850 1.15 1.00 1.00 0.949 1.500 - 1.15 1.00 1.00 2 <br /> Fcp 405 - 1.00 1.00 - - - - 1.00 1.00 - p l <br /> E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 2 <br /> Emin' 0.47 million 1.00 1.00 - - - - 1.00 1.00 2 <br /> CRITICAL LOAD COMBINATIONS: <br /> Shear LC 02 = D - S <br /> Bending(+): LC 82 = D + g <br /> Deflection: LC M2 = D + S (live) - <br /> LC 02 = D + S (total) <br /> D-dead S=snow _ <br /> Al LC's are listed in the Analysis output - i I;' !;ice - ¢ <br /> Load Patterns: 5=5/2, X-L+S or L+Lr, =no pattern load in this span <br /> Load combinations: ASO Basic from ASCE 7_16 2.4 / IBC 2018 1605.3.1 <br /> CALCULATIONS: <br /> V max = 198, V design - 175 lbs; M(+) - 263 lbs-ft <br /> EIy - 6.97 1-b-in'2 N <br /> "Live- deflection is due to all non-dead loads (live, wind, snow-) /r',,, <br /> Total deflection - 1.0 dead+ "live" �', / r /' L. U �� .✓- <br /> Bearing: Allowable bearing at an angle F'theta calculated for each support <br /> as per NDS 3.10.3 :•r f �1 ,{ <br /> Lateral stability(+): Lu - 5.31' Le = 9.75' RB = 13.5 �y,� <br /> Design Notes: ( l- f <br /> 1.Analysis and design are in accordance with the ICC International Building Code(IBC 2018)and the National Design Specification(NOS 2018),using Allowable Stress Design(ASD).Design <br /> values are from the NOS Supplement <br /> 2_Please verify that the default deflection limits are appropriate for your application. <br /> 3.Sawn lumber bending members shall be laterally supported according to the provisions of NOS Clause 4.4.1. <br /> 4.SLOPED BEAMS:level bearing is required for all sloped beams. <br />
The URL can be used to link to this page
Your browser does not support the video tag.