My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 11:49:55 AM
Creation date
1/2/2026 11:49:09 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Permit
M2407-078
Year
2024
Notes
BLDG 40-26 1ST FLR HVAC, Compressed Air, Vacuum and Water
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS LEGEND <br /> A COMPRESSED AIR FLR FLOOR SA SUPPLY AIR GENERAL DUCTWORK SANITARY WASTE PIPING AND FITTINGS PIPING IDENTIFICATION <br /> AAV AUTOMATIC AIR VENT FPM FEET PER MINUTE SAN SANITARY 24x12 RECTANGULAR DUCT, FIRST NUMBER AIR TERMINALS (CONTINUED) p FED FUNNEL FLOOR DRAIN —CHWS CHILLED WATER SUPPLY <br /> AD ACCESS DOOR FT FEET SD SMOKE DAMPER 24x12 INDICATES SIZE FOR SIDE SHOWN EXHAUST GRILLE/REGISTER <br /> AFF ABOVE FINISHED FLOOR SENS SENSIBLE i <br /> AP ACCESS PANEL GA GAUGE SP STATIC PRESSURE !fir? (WALL) ❑D FD FLOOR DRAIN CHWR CHILLED WATER RETURN <br /> EXISTING DUCT TO BE REMOVED <br /> AHU AIR HANDLING UNIT GAL GALLON SO SQUARE CD-XXX o FCO FLOOR CLEANOUT CW CITY WATER DOMESTIC <br /> Al ANALOG INPUT GALV GALVANIZED SS STAINLESS STEEL 2 � SUPPLY AIR DUCT SHOWN IN SECTION, ARROW (DOMESTIC) <br /> SQUARE SUPPLY AIR DIFFUSER <br /> AO ANALOG OUTPUT GV GROOVED JOINT WITH COUPLING STM STEAM POINTS TO SIDE CALLED OUT FIRST Q <br /> A/C AIR CONDITIONING GPH GALLONS PER HOUR CO CLEANOUT, EXPOSED CITY WATER (DOMESTIC) <br /> AW AQUEOUS WASH GPM GALLONS PER MINUTE TEFC TOTALLY ENCLOSED FAN COOLED 24x � RETURN, EXHAUST OR OUTDOOR AIR DUCT SHOWN IN RG/EG/TG-XXX <br /> AWN AQUEOUS WASH WASTE GWB GYPSUM WALL BOARD TEMP TEMPERATURE SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST WCO WALL CLEANOUT A COMPRESSED AIR (100 PSIG NOMINAL) <br /> AWND AQUEOUS WASH WASTE DRAIN TYP TYPICAL RETURN/EXHUAST/TRANSFER GRILLE LATERAL HW HOT WATER (DOMESTIC) <br /> HOA HAND OFF AUTO 24 � ROUND DUCT, NUMBER ~ <br /> BHP BRAKE HORSEPOWER HP HORSE POWER V VOLTS 24 0 INDICATES DIAMETER <br /> 1 � DOOR AIR TRANSFER GRILLE SANITARY WYE AND 1/8 BEND HOT WATER (DOMESTIC) <br /> BLDG BUILDING HR HOUR VAV VARIABLE AIR VOLUME <br /> BTU BRITISH THERMAL UNIT HWC HOT WATER CIRCULATING VEL VELOCITY SUPPLY AIR DUCT, SQUARE OR ROOF AIR INTAKE - AHU <br /> HZ HERTZ VERT VERTICAL RECTANGULAR,ELBOW TURNING TOWARD WASTE PIPING QUARTER BEND —HWC— HOT WATER CIRCULATING (DOMESTIC) <br /> CAP CAPACITY HxW HEIGHT BY WIDTH VFD VARIABLE SPEED DRIVE WASTE PIPING BEND WITH CLEANOUT HOT WATER CIRCULATING (DOMESTIC) <br /> CFM CUBIC FEET PER MINUTE VTR VENT TO ROOF SUPPLY AIR DUCT, SQUARE OR ° <br /> C CENTER LINE IN INCHES W WITH RECTANGULAR ELBOW TURNING AWAY UPS LOW PRESSURE STEAM <br /> COL COLUMN W INDUSTRIAL WASTE WE WET BULB <br /> CONN CONNECTION WG WATER GAUGE RETURN AIR DUCT, SQUARE OR ROOF DRAIN PIPING MPS MEDIUM PRESSURE STEAM <br /> CW CITY WATER (DOMESTIC) KW KILOWATT WHA WATER HAMMER ARRESTER RECTANGULAR ELBOW TURNING TOWARD <br /> CMU CONCRETE MASONRY UNIT WxH WIDTH BY HEIGHT GENERAL PIPING RD ROOF DRAIN C GRAVITY STEAM CONDENSATE RETURN <br /> CHWS/R CHILLED WATER SUPPLY/RETURN LBS POUNDS RETURN AIR DUCT, SQUARE OR <br /> LWT LEAVING WATER TEMPERATURE #" # - INCHES RECTANGULAR ELBOW TURNING AWAY NEW AND EXISTING WORK - 0 VTR VENT THROUGH ROOF CD GRAVITY COOLING COIL CONDENSATE DRAIN <br /> D INDIRECT DRAIN # - FEET DESIGNATED BY NOTE <br /> # ROUND DUCT <br /> DB DRY BULB MAX MAXIMUM ROUND DIAMETER ELBOW TURNING TOWARD EXISTING TO BE REMOVED DIED OVERFLOW DRAIN CV CONDENSATE RELIEVER VENT <br /> DEC DIRECT DIGITAL CONROL MBH THOUSAND BTU PER HOUR F DEGREES FAHRENHEIT <br /> DISCH DISCHARGE MECH MECHNICAL AP PRESSURE DIFFERENCE/ SAN SANITARY WASTE ABOVE GRADE <br /> PRESSURE DROP ROUND DUCT PLUMBING FIXTURES <br /> DI DIGITAL INPUT MIN MINIMUM ELBOW TURNING AWAY HIDDEN OR BELOW GRADE <br /> DIA DIAMETER SAN SANITARY WASTE BELOW GRADE <br /> DUFF DIFFERENCE NC NOISE CRITERIA TRANSITION, RECTANGULAR TO RECTANGULAR 8J ❑ EWC ELECTRIC WATER COOLER <br /> V SANITARY VENT ABOVE GRADE <br /> DN DOWN NO NORMALLY OPEN OR ROUND TO ROUND CONNECTING LINES <br /> DO DIGITAL OURPUT n <br /> CA OUTDOOR AIR TRANSITION,D RECTANGULAR <br /> U AR I �! 4 WC-1 WATER CLOSET V SANITARY VENT BELOW GRADE <br /> TO ROUND EAT ENTERING AIR TEMPERATURE OC ON CENTERS CROSSING LINES, NON—CONNECTING (TOP OR F FIRE WATER MAIN <br /> ELF EFFICIENCY I EL ELEVATION PCW PUMPED COLD WATER FLEXIBLE DUCT <br /> FRONT PIPE IS SHOWN AS SOLID LINE) Q URINAL (UPSTREAM OF ALARM VALVE) <br /> � <br /> ELEC ELECTRICAL PD PRESSURE DROP OR PRESSURE DIFFERENTIAL <br /> �A7 <br /> EMS ENERGY MANAGEMENT SYSTEM PH PHASE PUMP (IN — LINE) S FIRE SPRINKLER PIPING EMCS ENERGY MANAGEMENT CONTROL SYSTEM PNEU PNEUMATIC RECTANGULAR DUCT, SQUARE ELBOW ® _77 LAVATORY DOWNSTREAM OF ALARM VALVE) <br /> EWT ENTERING WATER TEMPTERATURE POC POINT OF CONNECTION WITH TURNING VANES PUMP TEST ALARM VALVE TEST PIPING <br /> EXH EXHAUST PSI POUNDS PER SQUARE INCH <br /> EXIST EXISTING PSIG PSI GUAGE ❑ ACCESS DOOR (AD) OR ❑ SERVICE SINK PHW PUMPED HOT WATER (DOMESTIC) <br /> EXT EXTERNAL RAG RETURN AIR GRILL A 'OH " ACCESS PANEL (AP) �— INSULATED PIPE <br /> DUCT MOUNTED EQUIPMENT pCW PUMPED CITY WATER (DOMESTIC) <br /> FC FAN COIL REF REFERENCE AD ACCESS DOOR PIPE IN BREAK USE WHERE SECTION OF PIPING <br /> FCO FLOOR CLEANOUT 1— ( CENTRIFUGAL FAN <br /> RM ROOM IS OMITTED FROM DRAWING FOR CLARITY) PC PUMPED STEAM CONDENSATE <br /> FIG FIGURE RPM REVOLUTIONS PER MINUTE FOR DNET FREE AREA)DIMENSIONS ARE DIRECTION OF FLOW CENTRIFUGAL FAN, INLET GUIDE VANES <br /> FD FLOOR DRAIN PIW PUMPED INDUSTRIAL WASTE <br /> NSTRUMENTATION IDENTIFICATION LETTERS RWL RAIN WATER LEADER <br /> FIRST LETTER 11 SUCCEEDING LETTER ❑ml FLEXIBLE CONNECTION SLOPE DN_ DIRECTION OF SLOPE DOWN <br /> RETURN AIR DUCT, SQUARE OR VALVES <br /> MEASURED OR MODIFIER READOUT OR OUTPUT MODIFIER RECTANGULAR ELBOW TURNING TOWARD <br /> INITIATING PASSIVE FUNCTION DUCT OFFSET UP OR DOWN FLEX CONNECTION <br /> VARIABLE FUNCTION X X <br /> I BLIND FLANGE —�c�I BALL VALVE <br /> � <br /> A ANALYSIS ALARM AIR DAMPERS V— BUTTERFLY VALVE <br /> B BURNER/ ] CAPPED PIPE END FAN POWERED AIR TERMINAL UNIT WITH GATE VALVE <br /> COMBUSTION VOLUME DAMPER ACOUSTICAL RETURN BOOT AND FILTER <br /> C CONTROL CONTROL F PLUGGED PIPE END ELECTRICAL CLEARANCE GLOBE VALVE <br /> D DIFFERENTIAL AAV AIR TERMINAL UNIT <br /> E VOLTAGE SENSOR PRIMARY NOTE: OPPOSED BLADE DAMPER AUTOMATIC AIR VENT SOUND BOOT AND FILTER �a �a ANGLE GLOBE VALVE, ELEVATION/PLAN <br /> ( BLDG EL. 100'-0" = SITE EL 548.33' <br /> ELEMENT) PRESSURE GAUGE WITH VALVE i�l CHECK VALVE <br /> DUCT DAMPER, MOTOR OPERATED FAN POWERED AIR TERMINAL © <br /> F FLOW RATE RATIO POINT OF CONNECTION DM (ELECTRIC OR PNEUMATIC) �� ELBOW TURNED DOWN OR AWAY UNIT WITH FILTER da SOLENOID OPERATED VALVE <br /> G GLASS ELEVATION STATION SYMBOL ELECTRICAL CLEARANCE �� BALANCING VALVE <br /> H HAND HIGH PARALLEL BLADE DAMPER ELBOW TURNED UP OR TOWARD AIR TERMINAL UNIT <br /> I CURRENT 11 INDICATE v FD v FS REDUCER, CONCENTRIC FILTER BALANCING VALVE W/ METERING PORTS <br /> J POWER SCAN FIRE DAMPER FIRE/SMOKE DAMPER INSTRUMENTATION AND CONTROL E�Z 2-WAY CONTROL VALVE <br /> K TIME, TIME TIME RATE SECTION LETTER OR DETAIL NUMBER (VERTICAL) (VERTICAL) A REDUCER, ECCENTRIC <br /> SCHEDULE OF CHANGE -*FD FIRE DAMPER FS FIRE/SMOKE DAMPER TEMPERATURE SENSOR, HUMIDITY SENSOR, 3-WAY CONTROL VALVE <br /> L LEVEL LIGHT LOW SHEET SHOWN ON E� (HORIZONTAL) (HORIZONTAL) STRAINER SMOKE DETECTOR, DUCT MOUNTED 400 <br /> M MOMENTARY MIDDLE SHEET TAKEN FROM Bp AUTOMATIC FLOW CONTROL VALVE <br /> TEE (NUMBER INDICATES GPM) <br /> O ORIFICE <br /> BACKDRAFT DAMPER vF PLUG VALVE <br /> UP SECTION DETAIL MARK TEE 10, <br /> P PRESSURE POINT (TEST) / � TEMPERATURE SENSOR <br /> CONNECTION CONICAL TAP (WALL MOUNTED) Z BACKFLOW PREVENTER <br /> Q QUANTITY INTEGRATE, (S) SUPPLY, (R) RETURN, (E) EXHAUST g TEE DOWN © THERMOSTAT - WALL <br /> TOTALIZE S-100--AIRFLOW (CUBIC FEET PER MINUTE) ©N THERMOSTAT - NIGHT 45 DEGREE LATERAL TAP FLOAT AND THERMOSTATIC ��— PRESSURE REDUCING VALVE <br /> * <br /> R RADIATION RECORD D1:6 TRAP ASSEMBLY III OS & Y VALVE <br /> S SPEED SAFETY SWITCH DIFFUSER NECK SIZE _ ED TEMPERATURE TRANSMITTER <br /> T TEMPERATURE TRANSMITTER AIR TERMINALS PIPE ALIGNMENT GUIDE <br /> DIFFUSER TYPE SD SMOKE DETECTOR � PRESSURE RELIEF VALVE <br /> U MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION El SUPPLY DIFFUSER <br /> PT PLUG <br /> V VIBRATION VALVE/DAMPER ® DIFFERENTIAL PRESSURE SWITCH --dam— MODULATING CONTROL VALVE <br /> W WEIGHT FORCE WELL DIFFUSER/GRILLE MARK SD 12x6 SIDE WALL SUPPLY AIR DIFFUSER, GRILLE, <br /> / �1100 CFM OR REGISTER I23 CARBON DIOXIDE SENSOR <br /> X UNCLASSFIED THERMOMETER <br /> VAV ® - 1 INDICATES SLOPE <br /> Y EVENT, STATE RELAY, COMPUTE, ERG 12x12 RETURN/EXHAUST REGISTER OR GRILLE, CEILING AIRFLOW SENSOR 1/8 <br /> OR PRESENCE OR CONVERT �'='100 CFM DUCT TYPE. RETURN GRILLE SHOWN "RG" WATER HAMMER ARRESTOR <br /> Z POSITION DRIVER, ACTU(E)OR VAV MARK 1000 CFM TRANSFER GRILLE ASSEMBLY STAND RD WH-L01,SIZE AS SHOWN ='Affiliated <br /> FLOOR # SEQUENTIAL # SIZE BASED ON P.D.I. <br /> X LOCAL INSTRUMENT XXX PANEL MOUNTED INSTRUMENT XXX EXISTING INSTRUMENTATION Engineers FOR REFERENCE ONLY <br /> �— RETURN, OUTSIDE OR EXHAUST Affiliated Engineers,ma <br /> AIR FLOW DIRECTION e WATER HAMMER ARRESTOR 5802 Research Park Boweord <br /> XXX SHARED HMI DISPLAY y (PLAN VIEW) Tel d6082382616 s371s <br /> INSTRUMENT FURNISHED WITH EQUIPMENT SUPPLY AIR FLOW DIRECTION Pra;ect# FACILITY DESIGN BY AEI DATE 02.21 24 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL 101 <br /> DATE o <br /> M <br /> K THIRD FLOOR CONFERENCE CENTER — IFC 586992-01 SAG/WH CEL 10.22.08 E 787 PIC THIRD FLOOR — 30% 586992-01 SAG/WH CEL 08.14.08 Ffi�w�s�,°ti y Sp <br /> THIS DESIGN AND/OR H K MECHANICAL LEGEND&ABBREVIATIONS 14547 10.15.12 <br /> ECIFICATION IS APPROVED SHEET <br /> BOE//VG® m p4 TITLE 787 SURGELINE <br /> CHECKED L 787 PIC DCN #4 586992-00 SAG/WH CEL 10.24.08 F 787 PRODUCTION INTEGRATION CENTER — 90% 586992-00 SAG/WH CEL 08.29.08 z APPROVED BY DEPT. DATE M OA \ <br /> — RECORD DRAWING CLEAN—UP J#586992-00 586992-01 DLR GROUP S.GORE 05.28.09 G 787 PIC THIRD FLOOR — 60% 586992-01 SAG/WH CEL 08.29.08 <br /> M 787 SURGE LINE WH SAG 10.15.12 H 787 PRODUCTION INTEGRATION CENTER — IFC 586992-00 SAG/WH CEL 09.12.08 'roNn� � APPROVED BUILDING 40-026 doe No. — coMR NO. <br /> o0o21$55 <br /> — RECORD SET J THIRD FLOOR CONFERENCE CENTER — 60% 586992-01 SAG/WH CEL 10.10.08 oziuizoz< APPROVED MECHANICAL MASTER EVERETT, WA DWG No. 40-026—MOA <br />
The URL can be used to link to this page
Your browser does not support the video tag.