My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 11:49:55 AM
Creation date
1/2/2026 11:49:09 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Permit
M2407-078
Year
2024
Notes
BLDG 40-26 1ST FLR HVAC, Compressed Air, Vacuum and Water
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N AXIAL <br /> MARK PIPE CORRUGATIONS TOTAL PANJUIGUIDE S ACIINNGI FROM EJ TO <br /> HEATING AND VENTILATION UNIT <br /> No. SIZE (IN) EACH END MOVEMENT (IN) FIRST GUIDE SECOND GUIDE REMARKS <br /> MARK LOCATION SERVICE SUPPLY FAN FAN MOTOR ELECTRIC PREHEAT COIL REMARKS <br /> EJ-10 3 8 7 1'-0" 3'-6" DOUBLE-EQUALIZING JOINT <br /> NO. CFM TOTAL SP WHEEL DRIVE WHEEL FAN BHP HP VOLT PH HZ EAT EAT KW ELECTRICAL AIR PD. <br /> IN. W.G. TYPE DIA RPM °F °F V PH HZ STAGES IN. WG <br /> EJ-11 3 5 4 3/8 1'-0" 3'-6" DOUBLE-EQUALIZING JOINT 3RD FLOOR STATIC TEST CONTROL PACE MODEL SCF-73A. ELECTRIC HEATING <br /> VU-1 COL 7.5/R CENTER VENTILATION 600 0.75 PC BELT 7.31 1428 0.17 0.5 120 1 60 16 70 10 480 3 60 1 0.022 COIL WITH SCR CAPACITY CONTROL. <br /> F(NIC)E <br /> 3 3 2 5/8 1'-0" 3'-6" DOUBLE-EQUALIZING JOINT <br /> 3 4 3 1/2 1'-0" 3'-6" DOUBLE-EQUALIZING JOINT <br /> STEAM PIPING EXPANSION LOOPS STEAM PRESSURE REDUCING VALVE <br /> LOCATION INLET OUTLET CAPACITY SIZE <br /> ELECTRIC REHEAT COILS LOCATION SERVICE PIPE LOOP SIZE DIST. BETWEEN DIST. BETWEEN REMARKS MARK (CATWALK) (PSIG) (Pslc) NOMINAL <br /> REMARKS <br /> oP DIA HXW ET FIRST GUIDES ANCHORS <br /> MARK LOCATION SERVICE CFM KW SIZE ELECTRIC POWER AIR REMARKS N.1-1 BPS 8" 22' X 11' 25' 127' P.O.C. 5 CATWALK COL 2/N CAST STEEL CONSTRUCTION <br /> EAT LAT PRV-7 195± 25 10,200 z WITH 300# RATING <br /> NO. F `F V PH HZ STAGES IN WG 40-2 PRV-8 CATWALK 195± 25 11,800 2 CAST STEEL CONSTRUCTION <br /> SUPPLY DUCT N.5-1 BPS 8" 25'-0" X 12'-6" 25' 150' COL 2/P WITH 300# RATING <br /> RHC-3 KITCHEN 53 80 1800 15 20x12 480 3 60 1 .055 DUCT HEATER W/SCR CAPACITY CONTROL <br /> FIRST FLOOR PRV-10 CATWALK 195± 25 5600 2 CAST STEEL CONSTRUCTION <br /> SUPPLY DUCT N.8-1 BPS 8" 22' X 11' 25' 127' COL 10/P WITH 300# RATING <br /> RHC-4 FIRST FLOOR DINING 53 80 2700 25 20x16 480 3 60 1 .055 DUCT HEATER W/SCR CAPACITY CONTROL <br /> RHC-5 SUPPLY DUCT SERVERY 53 80 2700 25 20x16 480 3 60 1 .075 DUCT HEATER W/SCR CAPACITY CONTROL P-1.6 BIDS 8" 20' X 10' 25' 100' <br /> FIRST FLOOR <br /> P-3 BIDS 8" 25'-0" X 12'-6" 50' 200' <br /> CONDENSATE RECEIVERS P-5 BIDS 8" 25'-0" X 12'-6" 50' 200' <br /> PUMP MIN. <br /> P-7 BIDS 8" 25'-0" X 12'-6" 50' 200' SAFETY RELIEF VALVE <br /> MARK LOCATION RECEIVER REMARKS SET OVER CAPACITY SIZE <br /> HE RPM VOLT PH HZ pRPSIGRE (PSIG) <br /> GPM CAPACITY P-9 BIDS 8" 25'-O" X 12'-6" 50' 200' MARK LOCATION P PRESS. LB/H ± ORIFICE REMARKS <br /> ACROSS BLDG. STEEL BODY & SPRING <br /> CR-9 FIRST FLOOR 2.0 1750 460 3 60 35 15 15 GAL DUPLEX PUMPS WITH P-11/11' BIDS 8" 26' X 36' 53' 203' EXPANSION JOINT SRV-7 PRV-7 30 10% 10,200 N 4"-300 INLET FLANGE <br /> COL. R 2.5 CAST IRON RECEIVER 4.34 SO. IN 6"-150 OUTLET FLANGE <br /> FIRST FLOOR DUPLEX PUMPS WITH N-3 MPS 6" 6' X 8' 50' 200' „P„ STEEL BODY & SPRING <br /> CR-10 COL. R 5.5 2.0 1750 460 3 60 35 9 15 GAL CAST IRON RECEIVER SRV-8 PRV-8 30 10% 11,800 6-300 INLET FLANGE <br /> 6.38 SO. IN 8"-150 OUTLET FLANGE <br /> CR-11 FIRST FLOOR 1.5 1750 460 3 60 30 15 15 GAL DUPLEX PUMPS WITH N-5 MPS 4" 12' X 6' 50' 200' N^ Y N <br /> COL. R 8.5 CAST IRON RECEIVER SRV-10 PRV-10 30 0% 10,200 4.34 SO. IN 4-150 INLET FLANGE <br /> ( ) 6"-150 OUTLET FLANGE <br /> CR-12 FIRST FLOOR 1750 45 GAL DUPLEX PUMPS WITH N-7 MPS 4" 12' X 6' 50' 200' <br /> COL, R/10 1.5 460 3 60 25 15 CAST IRON RECEIVER <br /> CR-14 TRENCH INTERSECTION 1750 30 GAL DUPLEX PUMPS WITH P-3 MPS 6" 16' X 8' 50' 200' <br /> COL. N.5/9.7 2.0 460 3 60 30 22.5 CAST IRON RECEIVER EXPANSION JOINT SET SCHEDULE <br /> P-5.5 MPS 4" 16' X 8' 50' 300' (BASED ON 200°F OPERATING TEMPERATURE) <br /> EXPANSION JOINT SIZE FACE-TO-FACE LENGTH V.S. PIPE TEMPERATURE AT INSTALLATION <br /> P-8 MPS 3" 10' X 5' 50' 200' NO. IN. 10° 20' 30' 40° 50' 60' 70' 80° 90, 100° <br /> EJ-10 3 44.50 44.20 43.89 43.59 43.28 42.98 42.67 42.37 42.06 41.76 <br /> AIR HANDLING UNITS EJ-11 3 34.75 34.60 34.45 34.29 34.14 33.99 33.84 33.68 33.53 33.38 <br /> SUPPLY FAN FAN MOTOR STEAM HEATING COIL FILTER EJ-12 3 28.25 28.16 28.06 27.97 27.87 27.78 27.68 27.59 27.50 27.40 <br /> MARK LOCATION SERVICE 30%EFF, 4'THICK <br /> OPERATING <br /> CFM TOTAL W.G. TYPE DRIVE WHEEL FAN HP VOLT PH HZ EAT EAT CAP FACE AIR WG TM PRESS LBS/HR TYPE WG DIRTY WEIGHT, LBS REMARKS EJ-13 3 31.45 31.37 31.30 31.23 31.16 31.09 31.02 30.95 30.89 30.82 <br /> IN. . DIA RPM °F °F MBH VEL FPM IN. WG PSIG FILTERS <br /> THROW PLUG FAN, DRAW THROUGH UNIT WITH NOTE: THE 10°F DIMENSION IS THE MAXIMUM ALLOWABLE FACE-TO-FACE <br /> AHUU26H TRUSS SPACE ASSEMBLY AREA 30000 2.5 B.I.-AF BELT 40.25 954 25 460 3 60 44 80 1166.4 682 .23 20 1241 AWAY .70 8000 ± INTEGRAL F/B HEATING COIL LENGTH OF EXPANSION JOINT. <br /> AIR CONDITIONING UNITS <br /> MARK B SUPPLY FAN B B RETURN FAN B B COOLING B HEATING COIL FILTER <br /> LOCATION SERVICE 30%EFF, 4"THICI, REMARKS <br /> NO. CF TSIDE AIR TOT. SO WHEEL DRIVE HEEL FAN gHP O VOLT PH HZ OT. SPL DRIVE HEELL <br /> BHP O VOLT PH HZ TOTALSENS AIR TEMP LVG AIR TEMP CHILLED WATER oP AIR oP WATER ROWS MAX FACE ELECTRICAL oP AIR MAX oP <br /> N. W.G. TYPE DIA RPM H N. W.G. DIA H FDB FWB FDB FWB EWT LWT N WG FT WG FINS IN VEL, FPM AT 'F LAT °F KW V PH HZ N WG TYPE N WG <br /> CATWALK 40-26 : 1ST FLR 4,500 1,450 B.I.-A.F. 3,330 29.1 6 THROW CONSTANT VOLUME UNIT <br /> HVAC-25 COL P.4/4.4 PANEL ROUTER SHOP (1) (2) 3.5 PLUG BELT 24 13925.55 10 460 360 (1) 5° BELT 24" 2.1 5.0 460 3 60 145.4 117.2 79.0 64.4 55.0 53.4 45 55 (3) 0.8 10 8 500 - - - - - - - AWAY 0 9W/ DUCT-MOUNTED HEATERS <br /> FOURTH FLR 6 THROW CONSTANT VOLUME UNIT. <br /> HVAC-29 P CBT TERMINALS RM 1 685 300 2.25 B.L-A.F. BELT 13 1100 0.98 2 460 3 60 - - - - - - - - - 49.1 44.7 80.3 64.8 56.0 55.1 45 55 9.8 0.8 10 500 69 80 6 460 3 60 0.8 AWAY 0.9 HEATER WITH SCR CONTROLS <br /> NOTES: (1) THE RENOVATION OF THE SPACE HVAC-25 SERVES INCLUDES A REDUCTION IN SQUARE FOOTAGE. WITH THIS, HVAC-25 SHALL BE BALANCED TO THE REDUCED AIRFLOWS LISTED IN SCHEDULE: THE AIRFLOWS WERE PREVIOUSLY LISTED AS 7,200 CFM FOR THE SUPPLY FAN ALAIRTEMPERATURE <br /> FOR THE RETURN FAN. <br /> COORDINATE ELECTRICAL CONTRACTOR PROVIDED VFD FOR EACH FAN. USE VFD AS MEANS TO ACHIEVE BALANCING TO THESE AIRFLOWS. VFD SIZE TO BE BASED ON MOTOR HP LISTED IN SCHEDULE - WHICH WERE VERIFIED IN FIELD. REFER TO SHEET 40-026-CWM506 FORN. <br /> (2) TO MAINTAIN THE ORIGINAL 32% MIN. OUTSIDE AIR, REBALANCE FROM THE ORIGINAL 2,320 CFM TO THE REDUCED FLOW LISTED. <br /> (3) REBALANCE FROM THE ORIGINAL 46.0 GPM (COIL CAPACITY 230.0 TOTAL MBH/188.6 SENS MBH) TO THE REDUCED FLOW LISTED. WITH THE LOWER FLUID VELOCITY IN COOLING COIL SOME EFFICIENCY LOSS MAY OCCUR. IF SO, INCREASE BALANCED FLOW UNTIL LISTED LEAVI IS ACHIEVED. <br /> STATIC TEST CONTROL CENTER AIR CONDITIONING UNITS ; <br /> MARK SUPPLY FAN CHILLED WATER COOLING COIL HUMIDIFIER HEATING <br /> LOCATION SERVICE @ 72' F DB, 50% RH REMARKS <br /> NO. CFM TOT. SO FLOW HE VOLT PH HZ TOTAL SENSIBLE EWT GPM S WATER LBS/HR KW KW STAGES <br /> N. W.G. MBH MBH F PSI <br /> 8 15 3 0 4 9 11 2 4 6 45 30 9 130 150 3 60 . . . . . .ACU-1 <br /> 3RD FLOOR STATIC TEST CONTROL DOWN 3 460 LIEBERT MODEL FH248C WITH (2) LEAK DETECTORS, SEISMIC ZONE 4 FLOORSTAND, FLOW SWITCH, <br /> 5900 0.3 <br /> COLUMN 7.5/R CENTER AIR COND. UNIT DISCONNECT SWITCH, SMOKE DETECTOR, AND ADVANCED MICROPROCESSOR CONTROL. � Affiliated <br /> 3RD FLOOR STATIC TEST CONTROL LIEBERT MODEL FH248C WITH (2) LEAK DETECTORS, SEISMIC ZONE 4 FLOORSTAND, FLOW SWITCH, A_I Engineers ISSUED FOR CONSTRUCTION <br /> ACU-2 COLUMN 7.5/R CENTER AIR COND. 5900 0.3 DOWN 3 460 3 60 150.9 130.6 45 30.2 4.9 11.0 4.8 15 3 Affill ed Engineers,I <br /> / UNIT DISCONNECT SWITCH, SMOKE DETECTOR, AND ADVANCED MICROPROCESSOR CONTROL. 5802Reu 1, Is Iu d <br /> Matlis8.2Wisconsin53]19 DESIGN BY - DATE <br /> PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK Te1608.238.2518 AEI 02.21.24 <br /> WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED P,oiec+a: <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY R.ANDERSON 02.21.24 HVAC SCHEDULES W8861360 <br /> RECORD DRAWING ISSUED TO OWNER MGM DJH 06.30.94 fi a. THIS DESIGN AND/OR of"'^sN,�y SPECIFICATION IS APPROVED PH ROEDL 02.21.24 SHEET � <br /> A 787 FA RECORD SET fisfiaes wH C. CARBON 06.22.07BOE/A/G® m`� = APPROVED BY DEPT. DATE rir`E 737 NORTH LINE - 40-26 TOWER RELOCATIONS DP 26.02 We <br /> 737 NORTH LINE-40-26 TOWER RELOCATIONS DP 26.02 W8861360 AEI B. FRIEDMAN 02.21.24 CHECKED m <br /> APPROVED BUILDING 40-026 <br /> JOB N0. COMP N0. <br /> B. FRIEDMAN 02.21.24 � <br /> oz/u/zoza APPROVED DWG N0. <br /> MECHANICAL MASTER EVERETT, WA 40-026-MOe <br />
The URL can be used to link to this page
Your browser does not support the video tag.