My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 11:49:55 AM
Creation date
1/2/2026 11:49:09 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Permit
M2407-078
Year
2024
Notes
BLDG 40-26 1ST FLR HVAC, Compressed Air, Vacuum and Water
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br /> 1. SEE SHEET MOI. <br /> S POINT OF CONNECTION <br /> ® AIR DROP DUPLEX/HARD <br /> 6 AIR DROP SIMPLEX/HARD <br /> 3 3.5 4 14�j 5 O VACUUM OUTLET/HARD <br /> PW PROCESS WATER <br /> GENERAL NOTES <br /> l> GLOBE VALVE SHALL BE CRANE 351 OR EQUAL. <br /> 3 2� 1/4" QUICK DISCONNET SOCKET, <br /> 3 4" CW & 2" V 3/4"CW 3' V UP 3 4' CW & 2' V TO EWC-1 4" V UP AND DN CEJN 10-310-1455 <br /> le TfO 2 <br /> EW 1/2 P AIR LINE FILTER. NORGREN MODEL F17—B00 M3DA. <br /> —1 PROVIDE METAL BOWL WITH SIGHT GLASS AND <br /> A — _ MANUAL DRAIN. 1" PORT SIZE. <br /> II+ AIR LINE REGULATOR. NORGREN MODEL <br /> FOR PROCESS WATER HOSE <br /> 1/2" A PIPE CONNECTION DETAIL os`" 3" U CAP 4 R17-800—RGLA. 1" PORT SIZE. <br /> 4L 1 <br /> 9' FROM FLOOR SEE , TYR — 3" 1 1/2" — 40-026—TN—P/4.5—CW-13 EL 6'-6" CL HFF L4__> BALL VALVE SHALL BE APOLLO 70-100 <br /> > OR EQUAL, TYPICAL. <br /> 1M126 M589 0 5� INTERGRATED LIQUID SEPARATOR/VACUUM FILTER <br /> REEL 2„ > 1/2"A DOWN TO AIR PUMP 1/4"A SHALL BE SOLBERG LRS-275-40OF <br /> OVER EXISTING 2" ® ©VACUUM HOSE, KANAFLEX 212—MK <br /> UNISTRUT F oN as a 4+ 0 4"SAN DOWONNECT TO (E) <br /> 9' FROM FLOOR PCW SAN IN T BELOW. 4" SAN <br /> BENCHLl <br /> 4"CW 7 NO SERVICE SHALL BE INTERRUP D OR <br /> 3 DO SSED AIR 6 �2 AC t FE-2 ^ CHANGED WITHOUT WRITTEN PERMISSION FROM <br /> iM126 M55 0 E R E DETAIL ' g 0 44, <br /> 1.. OWNER. <br /> TYR a ®ALL EXISTING PIPING AND EQUIPMENT <br /> 1 <br /> �26 M552 N 9e 2 1 W OR VACUUM LOCATIONS SHOWN ARE BASED ON AVAILABLE <br /> 40-026—TN—R/4.5—C —12 INFORMATION AND FIELD OBSERVATIONS. <br /> z E ONNECTION DETAIL w CONTRACTORS TO VERIFY LOCATIONS AND FIEL <br /> 1/2"DN EE TYP ao CONDITIONS PRIOR TO START OF NEW WORK. <br /> ~ 1M126 M564 2"CIN <br /> „(E) pr(E) <br /> 5 2,.AT/ 5/8"A HOSE/2 D 4"CWR 0 OSTER <br /> PUMP SECOND FLOOR £� 1"cw DN REFERENCE DRAWINGS <br /> (OFD) UP <br /> v FIRE RI <br /> } noa 3 (REF)o o O R <br /> 3'bAC EXHAUST UP 4 ROG 1/4" A DN <br /> AND ELIMINATE OUTSIDE OF 1"A UP 2 DN 4" SAN FROM BELOW CONSTRUCTION NOTES <br /> BUILDING AT 12' AFF, TYR 4 "A UP 1"A UP 3 1"A UP 2" CW UP CAP 6" ABOVE FLOOR <br /> REMOVE EXISTING SINK. CAP WATER <br /> AIR MANIFOLD 16"RWL (RD) UP AN DN 3" SAN UP SUPPLY LINES AT NEAREST MAIN OR <br /> FOR VACUUM SHUTOFF VALVE. CAP EXISTING WASTE PIPE <br /> CONNECTION DETAIL <br /> SPILL 12" OFD SEPERATOR DETAIL SEEL:L TYR <br /> AT FLOOR/WALL. PATCH AS NEEDED TO <br /> 1'-6" ABOVE GRADE SEE , TYP 1M126 M552 MATCH ADJACENT. <br /> 1M126 M589 1"A UP <br /> REMOVE EXISTING VACUUM PUMP AND <br /> PIPING. <br /> © DISCONNECT AIR LINE FROM EACH SHIM <br /> MILL. REMOVE AND DISPOSE of COOLANT <br /> SEPARATOR AND VACUUM SYSTEM FOR <br /> EACH SHIM MILL. <br /> PARTIAL 1ST FLOOR PLUMBING PLANI� <br /> SCALE: 1/8"= 1'-0" 8' 4' 0 4' 8' 16' <br /> SCALE: 1/8"=1'-0" <br /> T <br /> T <br /> 5 T <br /> 0.9B DG 40025 <br /> N <br /> 1M110 1M111 1M112 1M113 1M114 0 <br /> N.3 1 <br /> M115 1M116 1M117 1M118 1M119 4 <br /> N.7 0 <br /> 1M120 1M121 1M122 1M123 1M124 <br /> m <br /> P <br /> M125 1M126 1M127 1M128 1M129 <br /> R <br /> REMOVAL = Affiliated ISSUED FOR CONSTRUCTION FUTURE 26 4o—ov <br /> I Engineers BUILDING 40-0 <br /> AtRxated E�9hee,=,Inc. KEY PLAN N <br /> 5802 Research Park Boulevard <br /> Madison,w.e m 53719 SCALE: NONE <br /> PROFESSIONAL STAMP A, SIGNATURE APPLIES TO WORK Tel 608.238.2616 DESIGN BY ALI DATE 02.21.24 <br /> WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED P,o7ect y: <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY RKE 07.17.92 0 It SUBTITLE CURRENT REVISION SYMBOL DATE o <br /> THIS DESIGN AND/oR CHECKED PARTIAL 1ST FLOOR PLUMBING PLAN REMOVAL W8861360 02.21.24 <br /> 737 NORTH LINE-40-26 TOWER RELOCATIONS DP 26.02 W8861360 AEI J.13-J.P. 02,21.24 - RECORD DRAWING CLEAN-UP 586992-01 DLR GROUP D. FRAHM 05.28.09 F?`°'`;�; RKE 07.17.92 SHEET <br /> Fw^x,6^y SPECIFICATION IS APPROVED <br /> A RECORD DRAWING CLEAN-UP 555672-04 DLR GROUP NAP 10.14.05 E SINK REPLACEMENT AND COOLANT RELOCATION W975568 DHT DH/FB 7.18.12 oA�.e z APPROVED BY DEPT. I DATE RKE 07.17.92 TITLE 737 NORTH LINE 40-26 TOWER RELOCATIONS DP 26.02 WHIR <br /> 126 R <br /> CHECKED <br /> B 787 FA RECORD SET 555886 WH C. CARBON 06.2207 F 5X5 RATE READINESS - RECORD SET W1426466 WH SAG 05.09.14 Appgoveo BUILDING 40-026 <br /> � � LMM 07.17.92 doe No. COMP No. <br /> C THIRD FLOOR CONFERENCE CENTER- 60% 586992-01 SAG/WH CEL 10.10.08 G RELOCATE HOSE REEL 16421192 RDN DH/FB 07.03.14 'O^'^� :#LMM 07.17.92 - <br /> D THIRD FLOOR CONFERENCE CENTER- IFC 586992-01 SAG/WH CEL 10.22.08 H SITE DRINKING FOUNTAINS- RECORD W4100227 FSI CMG 12.15.17 oziuizoz< APPROVED MECHANICAL MASTER COL. P-R/3-5 EVERETT, WAI DWI NO. 40-026-1 M126R <br />
The URL can be used to link to this page
Your browser does not support the video tag.