My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 11:49:55 AM
Creation date
1/2/2026 11:49:09 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Permit
M2407-078
Year
2024
Notes
BLDG 40-26 1ST FLR HVAC, Compressed Air, Vacuum and Water
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HUMIDIFIER SUPPLY FANS <br /> MARK IDENTIFICATION LOCATION SERVICE CAPACITY APPROXIMATE SIZE STAGES POWER EAT LAT EA LA ELECTRICAL MODEL REMARKS <br /> (LBS/HR) (KW) DB F DB F RH % PH % FAN FAN MOTOR <br /> MARK LOCATION SERVICE OPERATING <br /> CURE HEAT SUPPLY UTILITY POSITION 119.7 CABINET: 2 42.0 101.8 105.0 13 39 480/3/60 CABINET: DRI-STEAA4 [1] [2] CFM IN PW G TYPE DRIVE WD A L RPM HE VOLT PH HZ WEIGHT, LBS REMARKS <br /> FAN <br /> 1 AIR & MAKEUP TRENCH 113 30"x34.1"x29" VLC 42-2 <br /> CABINET/DISPERSION DISPERSION PANEL: DISPERSION PANEL: <br /> PANEL 28"x27" ULTRA-SORB TV <br /> SF TUNNEL INLINE 95 PROVIDE COMBINATION MOTOR STARTER/DISCONNECT <br /> CURE HEAT SUPPLY UTILITY POSITION 119.7 CABINET: 2 42.0 101.8 105.0 13 39 480/3/60 CABINET: DRI-STEAM [1] [2] 15 COL. N.5/8.2 VENTILATION 400 0.25 CENT. BELT 12 1373 /2 460 3 60 FAN SHALL BE GREENHECK MODEL BSQ-120-5 <br /> 2 AIR & MAKEUP TRENCH 2 30"x34.1"x29" VLC 42-2 SF TUNNEL NLINE PROVIDE COMBINATION MOTOR STARTER/DISCONNECT <br /> CABINET/DISPERSION DISPERSION PANEL: DISPERSION PANEL: C VENTILATION 00 0.25 E ;BELT <br /> ELT ;138 /2 460 3 60 95 - <br /> PANEL 28"x27" ULTRA-SORB LV <br /> SCHEDULE NOTES: <br /> [1] HUMIDIFIER SHALL BE CONSTRUCTED OF 316 STAINLESS STEEL. N A A E - - E <br /> [2] PROVIDE WITH VAPOR-LOGIC CONTROLS OPTION. c!""r 18 POSITION 3 6500 3.0 AXIAL 153 7.5 460 3 60 387 FLOW FAN <br /> SF UTILITY TRENCH POSITION 4 6500 3.0 VANE BELT 18.4 2153 7.5 460 3 60 387 FAN SHALL BE TWIN CITY - QSL 182 - MIXED <br /> 19 AXIAL FLOW FAN <br /> AIR HANDLING UNIT SCHEDULE <br /> FAN MOTOR PRE-FILTER FINAL FILTER COOLING COIL STEAM COIL ELEC HEATING COIL <br /> MARK NO LOCATION SERVICE CFM ESP TYPE ARRANGE- DRIVE WHEEL DIA RPM MAX HE VOLTS PHASE HERTZ INITIAL APD FINAL APD INITIAL APDFINAL APD MAX APD MAX FV EAT EAT LAT GPM EWT LWT MAX WED FLUID TYPE MAX APD MAX FV EAT LAT STM PRESS CAP LBS/HR TOTAL CAPACITY NO. STEPS MANUFACTURER MODEL REMARKS <br /> N. W.G. VENT INCHES BHP IN. W.G. IN. W.G. IN. W.G. IN. W.G. IN. W.G. FPM DB F WE F DB F F F FT. W.G. /GLYCOL IN. W.G. TRIM DB F DB F PSIG MBH kW CONTROL <br /> HVA SECOND FLOOR COMAKEDUPPACE 8400 9.43 AIRFOIL NO. 3 BELT 24 2764 23.6 30 460 3 60 0.28 1.00 0.25 1.00 0.46 388 85.0 66.0 50.9 78 45 55 7.51 - 0.12 386 21.0 120 20 1117.0 1189.1 - - TEMTROL [4] [1] [2] [3] [5] [6] <br /> HVAC UTILITY TRENCH CURE HEAT SUPPLY 4000 2.5 PLENUM - DIRECT 20 2508 4.1 7.5 460 3 60 0.27 0.67 - - 0.83 492 75.0 67.0 55.7 28.9 45 55 12.83 PROP/20% - - - - - - - 25.1 SCR TEMTROL - [2] [5] [7] <br /> 34 AIR AND MAKE-UP <br /> HVAC UTILITY TRENCH CURE HEAT SUPPLY 4000 2.5 PLENUM - DIRECT 20 2508 4.1 7.5 460 3 60 0.27 0.67 - - 0.83 492 75.0 67.0 55.7 28.9 45 55 12.83 PROP/207 - - - - - - - 25.1 SCR TEMTROL - [2] [5] [7] <br /> 35 AIR AND MAKE-UP <br /> REMARKS <br /> [1] FACE AND BYPASS STEAM COIL WITH OPPOSED BLADE CONTROL DAMPERS <br /> [2] TEFC, VFD DRIVEN MOTOR AIR GRILLE SCHEDULE <br /> [3] 2 INCH THICK THROWAWAY PANEL PRE-FILTERS (MERV 7) <br /> [4] WF-DH17 INLET/NECK MAXIMUM MAXIMUM <br /> [5] FIELD INSTALLED VFD BY ELECTRICAL CONTRACTOR MARK TYPE MATERIAL SIZE NOISE TP MAXIMUM REMARKS <br /> [6] 12 INCH CARTRIDGE THROWAWAY FINAL FILTERS (MERV 11) INCHES COEFFICIENT INCH WG SET CFM <br /> [7] 4 INCH THICK PRE-FILTERS (MERV 8) SG <br /> 1 SUPPLY GRILLE STEEL 30x14 33 0.10 2000 TITUS 30ORL <br /> EXHAUST FANS 2 SUPPLY GRILLE STEEL 18x18 34 0.11 1650 TITUS 30ORL <br /> 2 <br /> FAN FAN MOTOR 3 SUPPLY GRILLE STEEL 14x14 27 0.08 825 TITUS 30ORL <br /> MARK LOCATION SERVICE OPERATING <br /> CFM SP TYPE DRIVE WHEEL FAN HP VOLT PH HZ WEIGHT, LBS REMARKS EG <br /> IN. W.G. DIA RPM 1 EXHAUST GRILLE STEEL 18x18 36 0.14 1700 TITUS 350RL <br /> E COL EIr6ELEC. RM. VENTILATION 8000 1.25 INLINE <br /> BELT 21 1326 5 460 3 60 381 PROVIDE COMBINATION <br /> MOTOR <br /> STARTER/DISCONNECT <br /> ( ) 2 EXHAUST GRILLE STEEL 14x14 32 0.10 875 TITUS 350RL <br /> 12 CIOL.TR/4.5 VENTILATION 750 3.15 USIET BELT 0 3058 2 460 3 60 140 FANVSHALL BE GREENHECKOMODEL SWB D2 0-20 <br /> ITY IDE COMBINATION ISCONNE CT TRG <br /> 1 RETURN GRILLE STEEL 48x48 36 0.07 8400 TITUS 63FL-HD <br /> EF ROOF UTILITY PROVIDE COMBINATION MOTOR STARTER/DISCONNECT <br /> 13 COL R 9.4 VENTILATION 1700 3.15 SET BELT 0 3016 2 460 3 60 140 FAN SHALL BE GREENHECK MODEL SWB-210-20 RG <br /> / 2 RETURN GRILLE STEEL 18x18 34 0.09 1400 TITUS 350RL <br /> FAN COIL UNIT SCHEDULE CEILING DIFFUSER STEEL 8110 22 0.07 300 TITUS MODEL TMS <br /> COOLING RETURN GRILLE ALUMINUM 22x22 31 0.09 2400 TITUS MODEL 50F 1/2x1/2x1/2 EGGCRATE RETURN <br /> MARK LOCATION FAN RGREMARKS 3 <br /> TOTAL SENS CHILLED WATER DP WATER EWT LWi CFM V/PH/HZ T, TRANSFER GRILLE STEEL SEE PLANS 20 0.10 2000 TITUS 350RL <br /> MBH MBH FT W.G. <br /> FC TUNNEL HPU RM 509 459 02 1-1/2" RIGHT HAND MCQUAY MODEL # FHZA1S20 <br /> 18 COL N.7 7.8 . . . CONNECTION 86 45 F 55 F 2000 460/3/60 FIELD INSTALL VALVE AND THERMOSTAT PACKAGE IN FAN COIL UNIT 2 TRANSFER GRILLE ALUMINUM 22x22 20 0.02 940 TITUS MODEL 50F 1/2x1/2x1/2 EGGCRATE RETURN <br /> FC TUNNEL HPU RM 50.9 45.9 10.2 1-1/2" RIGHT HAND 86 45 F 55 F 2000 460/3/60 MCQUAY MODEL FHZA1S20 <br /> 19 COL N.4 3.5 CONNECTION FIELD INSTALL VALVE AND THERMOSTAT PACKAGE IN FAN COIL UNIT <br /> FC TUNNEL HPU RM 50.9 45.9 10.2 1-1/2" RIGHT HAND 86 45 F 55 F 2000 460/3/60 MCQUAY MODEL FHZA1S20 <br /> 20 COL N.4 2 CONNECTION FIELD INSTALL VALVE AND THERMOSTAT PACKAGE IN FAN COIL UNIT PUMPS <br /> ELECTRIC REHEAT COILS APPROXIMATE SIZE PUMP ELECTRICAL RECEIVER <br /> MARK IDENTIFICATION LOCATION SERVICE DISCH MODEL REMARKS <br /> �P (LxWxH) FLOW PRESS MOTOR SPEED INLET SIZE DISCHARGE VOLTS AMPS PHASE MAT'L CAPACITY <br /> MARK LOCATION SERVICE EAT LAT CFM KW SIZE ELECTRIC POWER AIR REMARKS (GPM) (PSIG) HE (RPM) (IN) SIZE (IN) (GAL) <br /> NO. F F V PH HZ STAGES IN WG <br /> CRP CONDENSATE UTILITY POSITION 20"x12"x25" 18 20 1/3 3500 2 3/4 208 1 STEEL 5.5 SHIPCO TYPE AC <br /> HC SUPPLY DUCT SHIM SHOP 53 80 1800 15 2002 480 3 60 3 .055 DUCT HEATER SHALL BE MARKEL 1 RECEIVER PUMP TRENCH 1B <br /> 3 FIRST FLOOR MODEL 480-3-HF-15KW-20W-12H-H3-1800-B-G CRP CONDENSATE UTILITY POSITION 20"x12"x25" 18 20 1/3 3500 2 3/4 208 1 STEEL 5.5 SHIPCO TYPE AC <br /> HC SUPPLY DUCT SHIM SHOP 53 80 2700 25 1 20x16 480 3 60 3 .055 DUCT HEATER SHALL BE MARKEL RECEIVER PUMP TRENCH 2 <br /> POSITION 16 70 110 2000 40 29.Sx27.375 480 3 60 2 .01 L L <br /> ��I Affiliated <br /> ISSUED FOR CONSTRUCTION <br /> 6 TRENCH PROVIDE WITH SCR CONTROL. IrD Aifllleled Bigineers,lnc. <br /> 5802 Research Park Boulevard <br /> HC PEDESTRIAN DUCT HEATER SHALL BE CHROMOLOX MODEL CABB 402 M.I-,Wi-m53719 DESIGN BY DATE <br /> 7 TUNNEL POSITION 2 70 110 2000 40 29.Sx27.375 480 3r6O 2 O1 PROVIDE WITH SCR CONTROL. PROFESSIONAL STAMP&SIGNATURE APPLIES TO WORK Te1808.288.Y818 AEI 02.21.24 <br /> WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED RroiaNa. <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY R.ANDERSON 02.21.24 HVAC SCHEDULE W8861360 <br /> H K C 02.21.24 <br /> RECORD DRAWING ISSUED TO OWNER FEW FEW 9 29 97 �c e. THIS DESIGN AND/OR <br /> / / "' SPECIFICATION IS APPROVED P. ROEDL 02.21.24 SHEET o <br /> BOE//VG® E 737 NORTH LINE - 40-26 TOWER RELOCATIONS DP 26.02 MOh2 <br /> A 787 FA RECORD SET 555886 WH C. LARSON 06.22.07 z APPROVED er DEPT. DATE <br /> B 787 PS SEALANT HEAT AND HUMIDIFICATION W2638149 FSi REG 10.09.14 cNECNED <br /> - RECORD DRAWING W2638149 FSi REG 1217.15 ,^� �01 APPROVED BUILDING 40-026 doe N0. COMP NO, <br /> B. FRIEDMAN 02.21.24 <br /> C 737 NORTH LINE-40-26 TOWER RELOCATIONS DP 26.02 W8861360 AEI B. FRIEDMAN 02.21.24 oziuizoz< APPROVED MECHANICAL MASTER EVERETT, WAI <br /> DWI NO. 40-026-MOH2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.