Laserfiche WebLink
PLUMBING FIXTURE SCHEDULE GENERAL NOTES <br /> DOMESTIC HOT WATER CIRCULATOR MARK DESCRIPTION WASTE VENT CW HW MOUNT. MANUFACTURER AND MODEL NUMBER REMARKS � WATER FILTER — OMNI UNDERSINK <br /> PUMP MOTOR WATER FILTER MODEL # U-25 SERIES <br /> WC-1 WATER CLOSET 4" 2" 1" 15"* AMERICAN STANDARD AFWALL 2257 MARK LOCATION LOCATE FOR CLEAR HANDICAP ACCESS TO SINK <br /> -- FLUSH VALVE: ZORN MODEL# ZEMS6000AV—IS—WS1 CAP.GPM HEAD FT. RPM INLET DISCH ZE HE VOLTS PH HZ REMARKS PROVIDED WITH T01 FILTER CARTRIDGE. <br /> WC-2 WATER CLOSET 4" 2" 1° 16"* WALL MOUNTED (HANDICAPPED) � WATER FILETR — EVERPURE H54—EV9252-67 <br /> HWC-9 1st FLR 10 6 1750 1/2" 1/2" 1/12 120 1 60 IN LINE BRONZE W/ REPLACABLE FILTER CARTIRDGE. <br /> AV-1 LAVATORY �,� 11h" �" �" _ AMERICAN STANDARD CADET 0427.444 ADA MEZZANINE2.5 <br /> FAUCET: ZURN MODEL# Z6915—CWB—TMV-1—F HWC-10 R-5.5 <br /> UR-1 URINAL 2" 11/2" 3/4" -- 24" AMERICAN STANDARD WASHBROOK 6501 HWC-11 MEZZANINE <br /> FLUSH VALVE: ZURN MODEL# ZEMS6000AV—IS—WS1 R-8.5 <br /> HWC-12 1st FLR <br /> WF-1 WASHFOUNTAIN 2" 11/z" 1" -- FLOOR MOUNTED CIRCULAR R-10.8 <br /> HWC-13 MECH ROOM R-9.25 10 25 1750 1 1" 1/2 1 460 3 60 IN LINE BRONZE <br /> WF-2 WASHFOUNTAIN 2" P�" -- FLOOR MOUNTED SEMI—CIRCULAR JAN ROOM <br /> HWC-14 3.5/R 3 5 2800 1/2" 1/2" 39 W 1 120 1 60 IN LINE BRONZE <br /> EWC-1 ELECTRIC WATER COOLER 11/2" 11/z" 2" 34" ELKAY MODEL ERPBM28K WALL MOUNTED (HANDICAPPED) <br /> 1 1 -- <br /> EWC-2 ELECTRIC WATER COOLER 1/2" 1/2 1/2 WALL MOUNTED LILT STATIONS AND SUMP PUMPS <br /> "� -- <br /> SUMP PUMP MOTOR <br /> EWH-1 ELECTRIC WATER HEATER -- -- 1/2" -- -- FAUCET: AMERICAN STANDARD MARK LOCATION SERVICE REMARKS <br /> DIAMETER DEPTH CAP. HEAD FT. RPM DISCH HP VOLTS PHASE TYPE <br /> SS-1 SERVICE SINK 3" 2" 3/4" 3/d' 48"** AMERICAN STANDARD ANDARDLL MODEL 12 GPM H2O SIZE <br /> # 8344.1 SUMP TO HAVE 4 2 CEMENT FLANGES <br /> /4 <br /> SSEW-1 SAFETY SHOWER & EMERGENCY 11 __ _ SE-6 P.5-4.8 SAN.SEWER 6'-0" 8'-0" 220 32 1750 4" 7.5 460 3 DUPLEX AND VORTEX IMPELLER <br /> EYE WASH SP-60 N-2.4 SUMP 2'-0" 3'-0" 12 15 1750 1 1/4" 1/3 120 1 SINGLE <br /> EEW-1 EMERGENCY EYE WASH (NOT USED) 11h„ 112 1/2" -- -- SP-61 N-2.8 SUMP 2'-0" 3'-0" 12 15 1750 1 1/4" 1/3 120 1 SINGLE <br /> AY R. SMITH MODEL 2010 SP-62 N-5.8 SUMP 2'-0" 3'-0" 12 15 1750 1 1/4" 1/3 120 SINGLE <br /> FD-1 FLOOR DRAIN AS NOTED -- -- -- WITH TRAP PRIMER CONNECTION <br /> SP-64 N-9.8 SUMP 2'-0" 3'-0" 12 15 1750 1 1/4" 1/3 120 1 SINGLE <br /> FFD-1 FUNNEL FLOOR DRAIN AS NOTED -- -- -- SP-65 P-2.4 SUMP 2'-0" 3'-0" 12 15 1750 1 1/4" 1/3 120 1 SINGLE <br /> RD-1 ROOF DRAIN AS NOTED — -- SP-66 P-2.8 SUMP 2'-0" 3'-0" 12 15 1750 1 1/4" 1/3 120 1 SINGLE <br /> OFD-1 ROOF DRAIN (OVERFLOW) AS NOTED <br /> SP-67 P-5.8 SUMP 2'-0" 3'-0" 12 15 1750 1 1/4" 1/3 120 1 SINGLE <br /> -- -- -- <br /> JUST SL—ADA SERIES A-18GA SP-69 P-9.8 SUMP 2'-0" 3'-0" 12 15 1750 1 1/4" 1/3 120 1 SINGLE <br /> SK-1 KITCHEN SINK 2" 2" V2' 34"** FAUCET: ELKAY # LKE4100 EC> SP-70 N.2-4.5 SUMP 2'-6" 4'-0" 40 22 1750 2" 1/2 120 1 SINGLE <br /> FS-1 FLOOR SINK 3 2 -- -- -- SP-71 N.2-8.2 SUMP 2'-6" 4'-0" 40 22 1750 2" 1/2 120 1 SINGLE <br /> WC-3 WATER CLOSET <br /> 4" 2" 1" -- 15" FLOOR MOUNTED W/ TRAP PRIMER ON VALVE SP-72 N.5-4.5 SUMP 2'_6" 4'-0" 40 22 1750 2" 1/2 120 1 SINGLE <br /> SP-73 N.5-8.2 SUMP 2'-6" 4'-0" 40 22 1750 2" 1/2 120 1 SINGLE <br /> FD-2 FLOOR DRAIN 2 /2' — -- -- W/TRAP PRIMER CONNECTION SP-74 N.8-4.5 SUMP 2'-6" 4'-0" 40 22 1750 2" 1/2 120 1 SINGLE <br /> FS-3 FLOOR SINK 2" 1 1/2" -- -- __ JAY R. SMITH MODEL 3160 W/1/2" OR 3/4" GRATE AS REQUIRED SP-75 N.8-8.2 SUMP 2'-6" 4'-0" 40 22 1750 2" 1/2 120 1 SINGLE <br /> 2" 1 1/2" __ JAY R. SMITH MODEL 3100-13 W/ ELECTRONIC TRAP PRIMER CONNECTION SP-76 P-8.75 SUMP 2'-6" 4'-0" 40 22 1750 2" 1/2 120 1 SINGLE <br /> FS-4 FLOOR SINK MODEL MPB-500-115V <br /> SP-77 P-11.0 SUMP 2'-6° 4'-0" 40 22 1750 2" 1/2 120 1 SINGLE <br /> SSEW-2 SAFETY SHOWER & EMERGENCY 11/4 HAWS MODEL 8309 W/ PRIVACY CURTAIN <br /> EYE WASH SP-78 P.7-1.0 SUMP 2'-0" 4'-0" 25 28 1750 2" 1/2 120 1 SINGLE <br /> ET-1 EXPANSION TANK -- -- 1= AMTROL MODEL ST-20V—C WITH MINIMUM PRESSURE OF 50 PSIG AND SP-79 P.7-3.0 SUMP 2'-0" 10'-0" 25 28 1750 2" 1/2 120 1 SINGLE <br /> MAXIMUM PRESSURE OF 120 PSIG <br /> * TO TOP OF SEAT ** OF FAUCETS SP-80 P.7-4.0 SUMP 2'-0" 4'-0" 25 28 1750 2" 1/2 120 1 SINGLE <br /> SP-81 P.7-6.0 SUMP 2'-0" 10'-0" 25 28 1750 2" 1/2 120 1 SINGLE <br /> SP-82 P.7-7.0 SUMP 2'-0" 4'-0" 25 28 1750 2" 1/2 120 1 SINGLE <br /> SP-83 P.7-9.0 SUMP 28 1750 2" 1/2 120 1 SINGLE <br /> SP-84 P.7-10.0 SUMP 2'-0" 4'-0" 25 28 1750 2" 1/2 120 1 SINGLE <br /> HEATER(EATER SP-85 P.7-11.0 SUMP 2'-0" 4'-0" 25 28 1750 2" 1/2 120 1 SINGLE <br /> MARK LOCATION STORAGE—GAL RECOVERY—GPH TEMP. RISE 'F SOURCE CAPACITY REMARKS SP-86 N.5-9.7 SUMP 2'-0" 4'-0" 25 28 1750 1 1/4" 1/2 120 1 SINGLE <br /> 1st FLR SP-87 P4-4.5 SUMP 2'-0" 4'-0" 23 15 1750 1 1/2" 1/2 120 1 SINGLE HYROMATIC, MODEL OSP50A1 <br /> WH-9 R-2 5 240 400 50° TO 120° 20 PSIG STM. 248 LBS/HR VERT 36"0X72" TANK <br /> WH-10 MEZZANINE <br /> R-5.5 P <br /> WH-11 MEZZANINE PUMPS STEAM TRAPS <br /> st F R <br /> 2nd FLR PUMP MOTOR MARK LOCATION SERVICE LB/HR SIZE TYPE REMARKS <br /> MARK LOCATION SERVICE CAP. HEAD REMARKS <br /> GPM FT RPM DISCH HP V 0 ST-1 CATWALK LEVEL HVAC-34 2^0 3/4" F & T TRAP INLET PRESS. APPRX. 20 PSIG <br /> COE 3/0 <br /> ELECTRIC WATER HEATER BP-1 MEZZANINE COLD WATER W/ TRANSFORMER AND 8.6 GALLON COL 3 Q <br /> 20 71 3500 1 1/2' 1 1/2 460 3 CATWALK LEVEL <br /> R-8.5 BOOSTER PRESSURE TANK ST-2 HVAC-34 260 3/4" F & T TRAP INLET PRESS. APPRX. 20 PSIG <br /> ELECTRICAL BP-3 1ST FLOOR COLD WATER 17 112 1070 2" 3 460 3 W/ TRANSFORMER AND 8.6 GALLON <br /> MARK LOCATION STORAGE FLOW RECOVERY TEMP. RISE 'F REMARKS R-2.5 BOOSTER PRESSURE TANK <br /> GAL GPH V KW HZ 0 DP-1 1ST FLOOR WASTE WATER 10 30 -- 1" -- -- -- DIAPHRAGM PUMP SHALL BE YAMADA <br /> R-10.5 FR. SS-1 MODEL NDP-15BPT <br /> EWH-1 5TH FLR -- 1 GPM -- 41 277 6 60 1 <br /> R-8.5 REMOVAL <br /> WHE-4 1ST FLR <br /> PLAZA 3.5/R -- Es 90 480 5 60 3 A.O. SMITH DSE-65 <br /> EWH-5 2ND FLR -- 1 GPM 42 208 6 60 3 CHRONOMITE TANKLESS <br /> KITCH 1/P I WATER HEATER. SR-30 <br /> EWH-6 4TH FLR 60 1.5 120 1 ARISTON ELECTRIC MINI WATER <br /> KITCH 3/R 2.5 -- 70 HEATER, GL2.5 F#MEERS <br /> ISSUED FOR CONSTRUCTION <br /> 3RD FLR 30 -- 17 70 208 3 60 1REST 3.5/R PROFESSIONAL STAMP & SIGNATURE a <br /> APPLIES TO WORK WITHIN THE CLOUDED Seattle//Spokane//Baltimore DESIGN BY Fq-I DATE 03.14.24 <br /> REVISION AREAS ONLY AS INDICATED <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE AWN OAIE SUBTITLE CURRENT REVISION SYMBOL GATE <br /> M cq o THIS ESIGN AND/R PIKE <br /> CKED -17-92 PLUMBING SCHEDULES-REMOVAL q W8861360 03.14.24 <br /> K THIRD FLOOR CONFERENCE CENTER — IFC 586992-01 SAG/WH GEL 10.22.08 E 787 PRODUCTION INTEGRATION CENTER — 90% 586992-00 SAG/WH GEL 08.29.08 �"�+sv SPECIFICATION IS APPROVED PIKE 7-17-92 SHEET <br /> L THIRD FLOOR CONFERENCE CENTER — DCN 2 586992-01 SAG WH GET 10.29.08 F 787 PIC THIRD FLOOR — 60% 586992-01 SAG WH CEL 08.29.08 �" " EN IN TITLE 737 NORTH LINE — 40-026 WING TANK CLEANOUT M 0 B R M <br /> / / �OL T, APPROVED BY DEPT. DATE RKE 7-17-92 <br /> M ELEVATOR SUMP PUMP 10735384 RON DH FB &20.10 G 787 PRODUCTION INTEGRATION CENTER — IFC 586922-00 SAG WH CEL 09.12.08 ` e CHECKEDcs <br /> / / LMM 7-1-92 BUILDING 40-026 <br /> JOB NO. COMP N0. <br /> N AQUEOUS WASH POS 3— RECORD WBS 252 JAL FSG 12.19.18 H THIRD FLOOR CONFERENCE CENTER — 60% 586992-01 SAG/WH CEL 10.10.08 Ss,oeniRL"`a�� LMM OveD 7 17 92 — <br /> P 737 NORTH LINE— 40-026 WING TANK CLEANOUT W8861360 FSi KMC 03.14.24 J 787 PRODUCTION INTEGRATION CENTER — DON 3 586992-00 SAG/WH GEL 10.20.08 11124 APPROVED MECHANICAL MASTER EVERETT, WA DWG NO. 40-026—MOBR <br />