Laserfiche WebLink
9 9.5 LEGEND <br /> FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEET MOD <br /> AWR = AQUEOUS WASH RETURN <br /> _____-_____j ________-___ P GENERAL NOTES <br /> TRAP SHALL BE ARMSTRONG 983-30 <br /> TRAP SHALL BE ARMSTRONG 980-60 <br /> FOR HVAC DRAIN TRAP CONNECTION DETAIL, <br /> SEE <br /> M454 M566 <br /> ® FOR RFPB CONNECTION DETAIL, SEE 5 <br /> M454 M567 <br /> 5. WATER HEATER PIPING SYSTEM VALVES AND STRAINERS: <br /> MPS GATE VALVES: CRANE 465 1/2 <br /> I MPS BALL VALVES: APOLLO 70-100 <br /> MPS WYE STRAINERS: PPI YFC125 <br /> C CONDENSATE BALL VALVES: APOLLO 70-100 <br /> CONDENSATE CHECK VALVES: CRANE 137 <br /> B CONDENSATE WYE STRAINERS: PPI TB150 <br /> WATER 3" BUTTERFLY VALVES: DEMCO 22121-5114351 <br /> UNIT HEATER, SEE 6 M454 M584 WATER 1-1/4" BALL VALVES: APOLLO 82-200 (3—PIECE) <br /> I <br /> I M454 M567 OR CONNECTION, SEE WATER 3" CHECK VALVES: CRANE 373 <br /> UH BP BP M454 M567 3 W D WATER 1-1/4" CHECK VALVES: CRANE 10707S <br /> " <br /> L 35 RG 3B 3A 3"PPCW DIN 6. HVAC DUCTWORK SPECIFICATIONS ON SHEET MO! SHALL APPLY. <br /> 1 FS <br /> 48x48 3 8 HT 1 4 2 4 WR & CHWS DIN7. REFER TO 40-026—MOi FOR HVAC PIPING SPECIFICATIONS. <br /> 3/4"CD DW TO THRU FIRST F <br /> FIRST FLOOR <br /> � A <br /> 2 1"MPS DIN3/4"TP M454 M584 <br /> 0 2"CD DIN CHWS I� 3"PPCW <br /> I 3"MPS DN ---- <br /> 24x60 CONSTRUCTION NOTES <br /> ------------ -- <br /> 3 Fs <br /> I FLEX I CONN--�- 3 4 1 NOT USED. <br /> I / T <br /> I I <br /> C 2�PROVIDE BOOSTER PUMPS 3P-3A AND BP-3B. MAINTAIN <br /> A MINIMUM OF 6" CLEARANCE AROUND EACH PUMP. <br /> 1-1/2"ID DIN PROVIDE 3' x 3' HOUSE KEEPING PAD AT 6" IN <br /> I I ELEVATION. <br /> HOUSEKEEPING PAD <br /> PROVIDE HYDROPNEUMATIC TANK, PIPED DOWNSTREAM OF <br /> STEAM COIL DISCHARGE OF BOOSTER PUMPS 3P-3A AND BP-313. <br /> CONNECTION, SEE HVAC ®PROVIDE ELECTRONIC FLOW SWITCH ON HORIZONTAL <br /> M44_566 33 BRANCH OF PIPING. <br /> COOLING COIL <br /> CONNECTION, SEETRAP PRIMER DDC PANEL <br /> M566 4"MPS 3/4"TP DIN <br /> REFERENCED DRAWINGS <br /> ------- ---- <br /> _� R <br /> 11 <br /> 18"0 UP PIPE GUIDE <br /> DETAIL, SEES\ (TYp) <br /> M454 M535 <br /> EXHAUST DUCT <br /> IF <br /> ENLARGED HVAC PLAN <br /> SCALE: 1/4"=1'-0" 2M29, 21VI79, M454 <br /> ISSUED FOR CONSTRUCTION <br /> PROFESSIONAL STAMP & SIGNATURE ENGINEERS <br /> APPLIES TO WORK WITHIN THE CLOUDED Seattle//Spokane//Baltimore DESIGN BY FSi DATE 03.14.24 SCALE: 1/4"=1'—O" <br /> REVISION AREAS ONLY AS INDICATED <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL C DATE <br /> M. ON ACCEPTABILITY D.Vu 05.30.06 ENLARGED HVAC PLAN W8861360 G 03.14.24 <br /> ORIG 787 FA 555886 RECORD SET WH C. LARSON 06.22.07 ��, wnsy THIS DESIGN AND/OR CHECKED ENLARGED <br /> 05.30.06 SHEET <br /> gyp` ' SPECIFICATION IS APPROVED M454 <br /> A 787 SURGE LINE WH SAG 10.15.12BOE/A/G® W ENGINEER TITLE 737 NORTH LINE — 40-26 WING TANK CLEANOUT <br /> APPROVED BY DEPT. DATE D.VU 05.30.06 <br /> B AQUEOUS WASH POS 3 — RECORD 252 JAL `SG 12.19.18 CHECKED <br /> C. CARBON Q5.3D.Q6 BUILDING 40-026 <br /> C 737 NORTH LINE— 40-26 WING TANK CLEANOUT W8861360 FSi KMC 03.14.24 e r ONA aENG a,��. APPROVED doe No. 555886 coMR No. <br /> APPROVED MECHANICAL MASTER COL. 7-8/N.5—P ORIG DWc NO. 40-026—M454 <br />