My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (3)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 12:03:14 PM
Creation date
1/2/2026 12:00:02 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Permit
M2407-044
Year
2024
Notes
Waste Water System and Process Water System Tank Cleanout
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br /> BRONZE STRAINER BALL VALVE TEST COCK(TYR) <br /> GAGE VALVES,OR BALL VALVES <br /> MP FLASH <br /> STEAM LINE <br /> SPACE THERMOSTAT CONTROL VALVE <br /> 3/4"TO 2"OUTLET MAX. PD=10PS1 <br /> 2" �SPARE 1"INLET - � STRAINER(TYR) <br /> GATE VALVE(TYR) GENERAL NOTES <br /> -- I <br /> 3"(TYP.) <br /> - - I <br /> SUPPLY 3/4"TO 2" C �3w"" ••n•,T,,,,, "•L"F F,ScrrRc-oii-sii�sr <br /> 6" 12"MIN. 6" 6" 6" I -nido"-�"�ncnc�rv�gR�c�--HSTEP--o D <br /> O 0 WATTS 90 PREVENTER, __ <br /> WATTS OW SERIES OR -- ---- ------------------ ---- �,4�S�nII,I(r S�,€4�iA I, IP <br /> AIR GAP EQUAL MPS (SEE PLAN FOR SIZE) <br /> PIPE TO FLOOR DRAIN II�I� RUN PIPING FULL CONNECTION iAin R um 4 n 419 n <br /> SIZE FROM MAINS TO UNIT99641919 <br /> �r7`rn <br /> — z 1/z"(nP.) — 12" MIN <br /> 3 3/4" <br /> 1.TO BE INSTALLED IN A CONTINUOUS PRESSURE WATER SUPPLY. 12" T <br /> 2. CAN BE INSTALLED HORIZONTALLY OR VERTICALLY.F&T TRAP <br /> 3.WATER SPILLAGE WILL LIKELY OCCUR.AN AIR GAP WITH DRAIN 1 1/2"DRAIN WITH CAP DIRT LEG CHECK VALVE <br /> LINE MAY BE INSTALLED AS REQUIRED. IN A VERTICAL INSTALLATION <br /> AN ELBOW IS ALSO NECESSARY AND FLOW MUST BE"UP". IF-al TO EXISTING CONDENSATE UNIT HEATER (VERTICAL SHOWN, <br /> 4. DESIGNED TO BE INSTALLED AT CROSS CONNECTIONS SUBJECT RELIEVER AND PUMP APPLIES FOR HORIZONTAL AS WELL) <br /> TO HIGH HAZARD BACK PRESSURE OR BACK SIPHONAGE. <br /> 5.VERY HIGH PRESSURE DROP. 6 <br /> GRAVITY FLOW CONDENSATE <br /> 6.ACCESS&CLEARANCE SHALL BE PROVIDED FOR REQUIRED RETURN (SEE PLAN FOR SIZE) <br /> TESTING, MAINTENANCE,&REPAIR: INCLUDING A MINIMUM OF 1'-0" `-' <br /> BETWEEN LOWEST PORTION OF ASSEMBLY,AND FLOOR OF PLATFORM. FLASH TANK MADE FROM 8"DIAMETER SCHEDULE 80 PIPE WITH <br /> ASSEMBLIES INSTALLED MORE THAN 5'-0"ABOVE FLOOR SHALL BE SCHEDULE 80 END CAPS WELDED TO PIPE. <br /> PROVIDED WITH A PERMANENT PLATFORM CAPABLE OF SUPPORTING A TANK LENGTH TO BE MINIMUM OF 36 INCHES. <br /> TESTER OR MAINTENANCE PERSON. PROVIDE AT LEAST ONE 1"DIAMETER SPARE CAPPED INLET. NOTE: ISOLATING VALVE MUST PROTECT ^A \/ <br /> INLETS SIZED TO MATCH CONDENSATE LINES. COMPLETE STEAM TRAP ASSEMBLY. REMOVAL NOTE S <br /> ALL TANK NOZZLES TO BE SCHEDULE 80 PIPE. <br /> INSULATE FLASH TANK. <br /> REMOVE AQUEOUS WASH (AW) PIPE LABEL. <br /> REDUCED PRESSURE PRINCIPLE C REMOVE EXISTING STEAM INSTANTANEOUS WATER <br /> BACKFLOW PREVENTER DETAIL TYPICAL FLASH TANK DETAIL UNIT HEATER CONNECTION DETAIL BACKETO RPPE. ET-'3 AN° ASS°G'ATE° P'P'N� <br /> SCALE: NONE M454 M567 SCALE: NONE M454 M567 SCALE: NONE M454 M567 REMOVE AQUEOUS WASH RETURN (AWR) PIPING. <br /> ® REMOVE EXISTING BOOSTER PUMP BP-1 AND ITS <br /> APPURTENANCES. <br /> 3/4"0 THREADED ROD <br /> a W/ HILTI-RE 500 <br /> 3"W FLOW SWITCH ; i� _ EMBED SO (TYR) <br /> 5" MIN <br /> AQUEOUS WASH C <br /> RELEIF VALVE BOOSTER PUMP = 3�'`� C <br /> REFERENCED DRAWINGS <br /> WALL-"" 3" HEAVY DUTY SINGLE PIPE CLAMP <br /> PRESSURE SWITCH STAUFF ORDER CODE SPAL/DUEB <br /> p 8088.9 PP DPAL-AS U W15 K. <br /> SECTION <br /> 2 GATE VALVE (TYR) <br /> 3"AW STRAINER <br /> COLD WATER 3" UNION (TYR)3"CW RPBFP Q E U AS URN 1/4"CS INVERTED BUCKET TRAP(HIGH PRESSURE) _ <br /> 3/8"INVERTED BUCKET TRAP(MEDIUM PRESSURE) <br /> / G M / 3 I. <br /> 3"A DRIP TRAPS SHALL BE LOCATED: - <br /> 12"MIN - 1.AT THE END OF STEAM MAINS <br /> MEDIUM PRESSURE STEAM 4,. _ ac, <br /> 2.ANY CHANGE OF ELEVATION OF <br /> 6"DIRT LEG STEAM PIPE - <br /> EXPANSION TANK FULL SIZE OF 3.WHERE INDICATED ON DRAWING <br /> 1/4 WATER HEATER 12' ET MAIN STEAM PIPE CHECK VALVE C 3"AW <br /> WH 3 WALL <br /> 13 <br /> F&T TRAP HIGH PRESSURE CONDENSATE TO FLASH TANK, PLAN <br /> MEDIUM PRESSURE CONDENSATE TO CONDENSATE <br /> RECEIVER AND PUMP <br /> WATER ' 'EATER WII-13 MALE: NONEPIPING CONNECTION M45 4 M56 °DRIP ERAP DETAIL M45 M567 PIPE°ANCHOR DETAIL NE GM116 M567 <br /> F�MEERS <br /> ISSUED FOR CONSTRUCTION <br /> REMOVAL PROFESSIONAL STAMP & SIGNATURE a <br /> APPLIES TO WORK WITHIN THE CLOUDED Seattle//Spokane//Baltimore DESIGN BY `Si DATE 03.14.24 <br /> REVISION AREAS ONLY AS INDICATED <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LRAVJN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> M, Cy AccEPrnBIurY D.vU os.3o.os HVAC DETAILS-REMOVAL <br /> pr Wqy q� THIS DESIGN AN <br /> CHECKED W8861360 C 03.14.24 <br /> ORIG 787 FA RECORD SET 555886 WH C. CARBON 06.22.07 ��' '6 SPECIFICATION IS APPROVED C. LARSON 05.30.06 SHEET <br /> A 787 SURGE LINE WH SAG 10.15.12 ® W APPROVED By DEPT. DATE DN vU 05.30.06 TITLE 737 NORTH LINE - 40-26 WING TANK CLEANOUT <br /> BOE//VG <br /> B AQUEOUS WASH POS 3 WBS 252 JAL FSG 12.19.18 CHECKED M 567 R x C. LARSON 05.30.06 BUILDING 40026 <br /> APPROVED JOB NO, COMP NO. <br /> C 737 NORTH LINE- 40-26 WING TANK CLEANOUT W8861360 FSi KMC 03.14.24 SS/ONAL ENG J - <br /> .JENKINS 05.30.06 <br /> APPROVED MECHANICAL MASTER EVERETT, WA Uwc N0. 40-026—M567R <br />
The URL can be used to link to this page
Your browser does not support the video tag.