LEGEND <br /> BRONZE STRAINER BALL VALVE TEST COCK(TYR) <br /> GAGE VALVES,OR BALL VALVES <br /> MP FLASH <br /> STEAM LINE <br /> SPACE THERMOSTAT CONTROL VALVE <br /> 3/4"TO 2"OUTLET MAX. PD=10PS1 <br /> 2., �SPARE 1"INLET - � STRAINER(TYR) <br /> GATE VALVE(TYR) GENERAL NOTES <br /> I <br /> SUPPLY 3/4"TO 2" 3 (N <br /> BACKFLOW PREVENTER, P') I <br /> I I <br /> 6" 12"MIN. 6" 6" 6" <br /> WATTS 909 SERIES OR -- ---- ------------------ ---- <br /> AIR GAP EQUAL MPS (SEE PLAN FOR SIZE) <br /> PIPE TO FLOOR DRAIN RUN PIPING FULL CONNECTION <br /> SIZE FROM MAINS TO UNIT <br /> 2 1/2"(TYP.) - 12" MIN <br /> 3 3/4" <br /> 1.TO BE INSTALLED IN A CONTINUOUS PRESSURE WATER SUPPLY. 12" IF�T�ti <br /> 2. CAN BE INSTALLED HORIZONTALLY OR VERTICALLY. F&T TRAP <br /> 3.WATER SPILLAGE WILL LIKELY OCCUR.AN AIR GAP WITH DRAIN 1 1/2"DRAIN WITH CAP 1 DIRT LEG CHECK VALVE <br /> LINE MAY BE INSTALLED AS REQUIRED. IN A VERTICAL INSTALLATION <br /> AN ELBOW IS ALSO NECESSARY AND FLOW MUST BE"UP". IF-al TO EXISTING CONDENSATE UNIT HEATER (VERTICAL SHOWN, <br /> 4. DESIGNED TO BE INSTALLED AT CROSS CONNECTIONS SUBJECT RELIEVER AND PUMP APPLIES FOR HORIZONTAL AS WELL) <br /> TO HIGH HAZARD BACK PRESSURE OR BACK SIPHONAGE. <br /> 5.VERY HIGH PRESSURE DROP. 6 <br /> GRAVITY FLOW CONDENSATE <br /> 6.ACCESS&CLEARANCE SHALL BE PROVIDED FOR REQUIRED RETURN (SEE PLAN FOR SIZE) <br /> TESTING, MAINTENANCE,&REPAIR: INCLUDING A MINIMUM OF 1'-0" <br /> BETWEEN LOWEST PORTION OF ASSEMBLY,AND FLOOR OF PLATFORM. FLASH TANK MADE FROM 8"DIAMETER SCHEDULE 80 PIPE WITH <br /> ASSEMBLIES INSTALLED MORE THAN 5'-0"ABOVE FLOOR SHALL BE SCHEDULE 80 END CAPS WELDED TO PIPE. <br /> PROVIDED WITH A PERMANENT PLATFORM CAPABLE OF SUPPORTING A TANK LENGTH TO BE MINIMUM OF 36 INCHES. <br /> TESTER OR MAINTENANCE PERSON. PROVIDE AT LEAST ONE 1"DIAMETER SPARE CAPPED INLET. NOTE: ISOLATING VALVE MUST PROTECT G ��`` <br /> INLETS SIZED TO MATCH CONDENSATE LINES. COMPLETE STEAM TRAP ASSEMBLY. CONSTRUCTION NOTES <br /> ALL TANK NOZZLES TO BE SCHEDULE 80 PIPE. <br /> INSULATE FLASH TANK. PROVIDE NEW LABEL TO EXISTING PIPE AS <br /> REDUCED PRESSURE PRINCIPLE "PUMPED PROCESS COLD WATER" (PPCW). <br /> BACKFLOW PREVENTER DETAIL TYPICAL FLASH TANK DETAIL UNIT HEATER CONNECTION DETAIL <br /> SCALE: NONE M454 M567 SCALE: NONE M454 M567 SCALE: NONE M454 M567 <br /> 3/4"0 THREADED ROD <br /> PUMPED PROCESS ° W/ HILTI-RE 500 <br /> COLD WATER SO ADHESIVE 5" MIN <br /> 3"PPCW C _ EMBED (TYR) <br /> 3"PPCW C <br /> REFERENCED DRAWINGS <br /> B WALL---' 3" HEAVY DUTY SINGLE PIPE CLAMP <br /> 3A 8088.9 PIPDER DPAL-AS U W15DUEB K. <br /> SECTION <br /> GATE VALVE (TYR) <br /> BP STRAINER <br /> COLD WATER 3" 3B 3"PPCW UNION (TYR) ° <br /> 3"CW RPBFP n' n' v a' 1/4"CS INVERTED BUCKET TRAP(HIGH PRESSURE) _ <br /> 3/8"INVERTED BUCKET TRAP(MEDIUM PRESSURE) <br /> �+ T DRIP TRAPS SHALL BE LOCATED: _ <br /> 12"MIN — 1.AT THE END OF STEAM MAINS <br /> HT 2.ANY CHANGE OF ELEVATION OF <br /> 1 6"DIRT LEG STEAM PIPE - <br /> FULL SIZE OF .WHERE INDICATED ON DRAWING C �3"PPCW <br /> MAIN STEAM PIPE <br /> CHECK VALVE 3 <br /> WALL <br /> HIGH PRESSURE CONDENSATE TO FLASH TANK, P LAN <br /> MEDIUM PRESSURE CONDENSATE TO CONDENSATE <br /> RECEIVER AND PUMP <br /> BOOSTER PUMP PIPING CONNECTION DETAIL M567 M454 M567 DRIP E M45RAP DETAIL PIPE DANCHOR DETAIL o SCALE: GM116 M567 <br /> F <br /> ISSUED FOR CONSTRUCTION <br /> PROFESSIONAL STAMP & SIGNATURE NEERS a <br /> APPLIES TO WORK WITHIN THE CLOUDED Seattle//Spokane//Baltimore DESIGN BY FSi DATE 03.14.24 <br /> REVISION AREAS ONLY AS INDICATED <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LR_K DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> M. CH,q ACCEPTABILITY D.VU 05.30.06 HVAC DETAILS W8861360 G 03.14.24 <br /> ORIG 787 FA RECORD SET 555886 WH C. LARSON 06,22.07 for THIS DESIGN AND/OR CHECKED \ <br /> tiP SPECIFICATION IS APPROVED C. LARSON 05.30.06 SHEET <br /> A 787 SURGE LINE WH SAG 10.15.12 L W APPROVED By DEPT. DATE D.VU 05.30.06 TITLE 737 NORTH LINE - 40-26 WING TANK CLEANOUT M 567 <br /> B AQUEOUS WASH POS 3 WBS 252 JAL FSG 12.19.18 CHECKED x C. LARSON 05.30.06 BUILDING 40-026 <br /> APPROVED JOB NO, COMP N0. <br /> C 737 NORTH LINE- 40-26 WING TANK CLEANOUT W8861360 FSi KMC 03.14.24 SS/ONAL ENG J.JENKINS 05.30.06 <br /> APPROVED MECHANICAL MASTER EVERETT, WA Dwc N0. 40-026-M567 <br />