Shah Residence—Tree Strike <br /> DEI January 23, 2025 <br /> ADIBBLE ENGINEERS INC <br /> Lastly, DEI noted a minimum four interior trusses,two on the east side and two on the west side,which had <br /> truss plates that became dislodged from the truss members(Photos#9-12). <br /> In addition to the damaged framing on the interior, DEI also observed damage to the roof from the exterior. <br /> Directly adjacent to the location where the tree impacted with the structure, DEI observed significant <br /> deflection and warping of the roof and damage to the venting and outriggers(Photo#13-14). <br /> Recommendations <br /> DEI recommends replacing the entire overframing in like kind at the portion of the house where the tree had <br /> made impact.Although not all rafters in the overframing were observed to be damaged at this time, <br /> replacing the ridge beam will require removing the rafters.Any structurally undamaged rafters verified by <br /> DEI may be reused.Additionally,the roof sheathing should be replaced in-kind where damage is present. <br /> For the trusses with top chord damage, DEI recommends retrofitting with a sistered LSL(Laminated Strand <br /> Lumber)member and installing a plywood gusset plate to strengthen the weakened area and redistribute <br /> the load. The calculations for the project conditions are provided in the following sections. Please reference <br /> SSK-2, SSK-3, and SSK-4 for the accompanying truss repair details. <br /> For the exterior truss with a displaced web member, DEI recommends that the contractor replaces or repairs <br /> in like kind the displaced member. If the displaced member has no damage,the contractor may return the <br /> disconnected member, so it is plumbed to its original condition. DEI recommends that these exterior studs <br /> be sheathed to the roof to provide a continuous lateral load path. <br /> For trusses where the truss plates have been dislodged, DEI recommends that gusset plates be provided <br /> with sufficient screws/nails to transfer the loads across the intersection points.As with the top chord damage <br /> repairs, details and calculations for this will be provided in the structural drawing and calculations submitted <br /> for permit. <br /> ITEM#2: DAMAGED DRYWALL AND INTERIOR FINISHES <br /> Observations <br /> DEI reviewed varying levels of damage to the drywall and other finishes. The conditions reflect severe <br /> drywall fractures. Drywall is a non-structural material, however, substantial cracking in drywall is an <br /> indicator of possible concealed framing damage.The following damage was observed. DEI recommends <br /> that the drywall be removed in the areas listed below to fully reveal the extent of structural damage. <br /> Drywall damages as follows: <br /> In the living room area adjacent to the fireplace <br /> In the hallway leading to the room where the tree strike occurred <br /> • In the hallway leading to the front door <br /> Recommendations <br /> DEI recommends the contractor remove the drywall at these locations to verify if any structural damage has <br /> occurred. If any damage is found, contact DEI for repair recommendations. <br /> PAGE 2OF7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.