PROJECT INFO&BUILDING CODE REQ'MTS WA STATE ENERGY CODE REQ'MTS GENERAL NOTES
<br /> PROJECT INFO 2021 MEG RESIDENTIAL 1 PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK,THE
<br /> PROJECT NAME: PARKVIEW EVERETT INTERIOR REMODEL R403 SYSTEMS CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES
<br /> PROJECTADDRESS: 302-76TH PL.SW,EVERETT,WA 98203 R503 ALTERATIONS NOTED AMONG OR BETWEEN THE CONTRACT DOCUMENTS,R503. BUILDING ENVELOPE OWNER-PROVIDED INFORMATION,SITE CONDITIONS,MANUFACTURERPROJECT NARRATIVE INTERIOR MODIFICATIONS AND HEATING SYSTEM RECOMMENDATIONS,OR CODES,REGULATIONS,OR RULES OFCHANGES. R5 .1.1.1 REPLACEMENT FENESTRATION JURISDICTIONS HAVING AUTHORITY. 1!1
<br /> R503.1.2 HEATINGANDCOOLING SYSTEMS
<br /> 2 PARKVIEW WILL PAY FOR BUILDING PERMIT.CONTRACTOR OR SUBS SHALL
<br /> PERMIT N: OBTAIN AND PAY FOR ALL TRADES PERMITS NECESSARY,I.E.ELECTRICAL,
<br /> PARCEL N: OM313DOWDBW TABLE R402.1.3 PLUMBING,MECHANICAL,ETC.THE CONTRACTOR SHALL BE RESPONSIBLE
<br /> LEGAL DESCRIPTION: LOT8 OF VIEW CREST DRIVE ACCORDING TO THE FOR VERIFICATION OF ALL EXISTING UTILITIES.THE CONTRACTOR SHALL
<br /> PLAT THEREOF RECORDED IN VOLUME 29 OF PLATS, FENESTRATION U-FACTOR 0.30 ALSO PAY FOR ALL OTHER CHANGES,FEES,OR COSTS CHARGED BY THE PERMIT HAS
<br /> PAGE 87,IN SNOHOMISH COUNTY,WASHINGTON. BUILDING AND CONSTRUCTION DEPARTMENTS,UTILITY AGENCIES,OR
<br /> PRIVATE COMPANIES WHICH REQUIRES SUCH COSTS FOR OR PRIOR TO
<br /> INSTALLATIONS.THIS INCLUDES STREET PERMITS AND ALL UTILITIES AS NOT BEEN
<br /> WELL AS BONDING.
<br /> SITEZONING: R-1,PER CHAPTER 19.04DEFINITION6 FOR"FAMILY"THAT 3 NOTUSED REVIEWED FOR
<br /> INCLUDES THE FOLLOWING WHEN LIVING TOGETHER AS A SINGLE, R301.1 CLIMATE ZONE SNOHOMISH COUNTY=4C 4 DRAWINGS:THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL ACCESSIBILITY
<br /> NOT-FOR-PROFIT HOUSEKEEPING UNIT:NOT MORE THAN EIGHT SCOPE OF WORK CONTRACTOR SHALL FIELD VERIFY EXISTING
<br /> DISABLED PERSONS,WHETHERADULTSOR MINORS,LIVING CONDITIONS&ALERT ARCHITECT/OWNER TO ANY UNFORESEEN AND ASBESTOS
<br /> TOGETHER IN A CONSENSUAL RESIDENTIAL LIVING CONSTRUCTION DIFFICULTIES PRIOR TO BEGINNING WORK.CONTRACTOR
<br /> ARNANG R50311 ALILDING ENVE ED.EXCEPTION .THE TH FOLLO
<br /> REQUIREMENTS SHALL COORDINATE WORK BETWEEN DISCIPLINES&SITE CONDITIONS. ABATEMENT
<br /> ICH
<br /> CONSTRUCTION TYPE: YG IRC FOR NEW CONSTRUCTION PROVIDED THE ENERGY USE OF 5 AREIN COMMON USE.THE ARCHITECT WALL DEFINE THE USE OF A ABBEVIATIONS THROUGHOUT THE PLAINS ARE ABBREVIATIONSNY IN
<br /> SPRINKLERS: NONE THE BUILDING IS NOT INCREASED: QUESTION.
<br /> SITE AREA: 4327.6 2.EXISTING CEILING,WALL OR FLOOR CAVITIES EXPOSED 6 ALL WORK IS"NEW'UNLESS NOTED AS'EXISTING".
<br /> DURING CONSTRUCTION PROVIDED THAT THESE CAVITIES
<br /> BUILDING AREA: 1197 SF+327 SF GARAGE ARE FILLED WITH INSULATION.2X4 FRAMED WALLS SHALL BE 7 REPETITIVE FEATURES NOT INDICATED IN THE DRAWINGS EVERYWHERE
<br /> OCCUPANCY: SINGLE FAMILY DWELLING PER IRC 2021 INSULATED TO A MINIMUM OF R-15 AND 2X6 FRAMED WALLS THAT THEY OCCUR SHALL BE PROVIDED AS IF DRAWN IN FULL.
<br /> SHALL BE INSULATED TO A MINIMUM OF R-21. 8 DO NOT SCALE DRAWINGS, cescngion
<br /> PARKING PROVIDED R503.1.1.1 REPLACEMENT FENESTRATION.WHERE SOME OR ALL OF AN 9 ALL DIMENSIONS ARE TO FACE OF WALL AND FACE OF CONCRETE
<br /> 2 STALLS EXISTING FENESTRATION UNIT IS REPLACED WITH A NEW UNLESS NOTED OTHERWISE.CONTACT ARCHITECT FOR ANY REQUIRED
<br /> ADA PARKING=O STALLS FENESTRATION PRO DUCT,THE REPLACEMENT CLARIFICATIONS.FIELD VERIFY EXISTING DIMENSIONS AND REPORT ANY
<br /> FENESTRATION UNIT SHALL MEET THE APPLICABLE DISCREPANCIES.
<br /> APPLICABLE CODES REOU I REMENTS FOR U-FACTOR AND SHGC IN TABLE R402.1.3. 10 NOTHING IN THE DRAWINGS&/OR THE SPECIFICATIONS SHALL BE
<br /> CONSTRUED TO PERMIT AN INSTALLATION IN VIOLATION OF APPLICABLE
<br /> 2021 INTERNATIONAL RESIDENTIAL CODE(IRC) R503.1.2 HEATING AND COOLING SYSTEMS.NEW HEATING,COOLING, CODES&/OR RESTRICTIONS.SHOULD ANY CHANGE IN THE DRAWINGS BE
<br /> 2021 INTERNATIONAL MECHANICAL CODE(IMC) AND DUCT SYSTEMS THAT ARE PART OF THE ALTERATION NECESSARY IN ORDER TO COMPLY WITH THE APPLICABLE CODES&/OR
<br /> 2021 INTERNATIONAL FIRE CODE(IFC) SHALL COMPLY WITH SECTION R403. REQUIREMENTS,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AT
<br /> ONCE AND CEASE WORK WORK ON ALL PARTS PERFORMED UNDER THIS
<br /> 2023 NATIONAL ELECTRICAL CODE(NEC) CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES,
<br /> 2021 WASHINGTON STATE PLUMBING CODE REGULATIONS,RESTRICTIONS,REQUIREMENTS,AND CODES.
<br /> 2017 ACCESSIBLE&USABLE BUILDINGS&FACILITIES(ICC/ANSI Al 17.1) 11 HAZARDOUS MATERIALS:SEE ASBESTOS REPORT FOR LOCATION OF
<br /> 2021 WASHINGTON STATE ENERGY CODE-RESIDENTIAL(WSEC RESIDENTIAL) KNOWN ASBESTOS.ADDITIONAL DISCOVERY OF HAZARDOUS MATERIALS
<br /> WAG 51-50 BUILDING CODE COUNCIL (ASBESTOS,CHEMICAL WASTES,PESTICIDES,ETC.)SHALL BE REPORTED
<br /> EVERETT ZONING CODE IMMEDIATELY TO THE OWNER.CONTRACTOR WILL WORK WITH OWNER
<br /> TO REMOVE&DISPOSE OF ANY HAZARDOUS MATERIALS.
<br /> 12 SAFETY:CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED
<br /> SAFETY PRECAUTIONS&METHODS,TECHNIQUES,SEQUENCES,OR pARKVIEW
<br /> PROCEDURES REQUIRED TO PERFORM THE WORK.
<br /> 13 ESDS:CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAININGANESDS EVERETT
<br /> BINDER AT THE SITE AND MEETING ESDS REQUIREMENTS PER SPECIFICATIONS 01 81 13 AND AS REQUIRED BY THE ESDS FORMS. INTERIOR
<br /> 14 PROTECT ALL ADJACENT PROPERTY,FENCES,AND VEGETATION.
<br /> PROTECT ALL STREET TREES,FIXTURES POLES,UTILITY EQUIPMENT AND REMODEL
<br /> OTHER APPURTENANCES ON PUBLIC PROPERTY.
<br /> 15 STOPS AND DAMPERS:FIRE STOPS IN WALL,SOFFITED CEILINGS,ETC.
<br /> SHALL BE PROVIDED PER CURRENT INTERNATIONAL BUILDING CODE 302-76TH PL.SW
<br /> REQUIREMENTS.PROVIDE SMOKE/FIRE DAMPERS AT ALL SUPPLY AND EVERETT,WA 0203
<br /> RETURN AIR OUTLETS,INLETS,OR DUCTS PENETRATING FIRE-RATED
<br /> ASSEMBLIES,ENCLOSURES,WALLS,FLOORS OR SURFACES AS REQUIRED
<br /> BY CODE AND/OR FIRE DEPARTMENT.
<br /> 16 WOOD:ALL MOD INCONTACTWITH CONCRETE SHALL BEPRESSURE CONSTRUCTION
<br /> TREATED PER CURRENT INTERNATIONAL BUILDING CODE.PRESSURE
<br /> TREATED WOOD SHALL ALSO BE USED FOR WOOD MEMBERS WHICH SET
<br /> FORM THE STRUCTURAL SUPPORT OF PORCHES,DECKS,AND TRELLISES,
<br /> ETC UNO.ALL STEEL FRAMING ACCESSORIES IN CONTACT WITH TREATED
<br /> LUMBER WALL BE RATED FOR CONTACT. am
<br /> 17 OPENINGS:ALL OPENINGS SHALL BE CAULKED,SEALED,OR
<br /> WEATHER-STRIPPED.
<br /> 18 ALL TEARS&JOINTS IN BATT INSULATIONS AT EXTERIOR WALLS SHALL BE pARKVIEW
<br /> SEALED PRIOR TO BEING COVERED.
<br /> 19 PROVIDE NEAT CUTS WHERE UTILITIES PENETRATE RATED WALL AND SERVICES
<br /> FLOOR ASSEMBLIES AND SEAL WITH NON-COMBUSTIBLE MATERIAL
<br /> IMPERVIOUS TO THE PASSAGE OF SMOKE.
<br /> 472D 200TH ST SW,STE ME
<br /> 20 TO MAINTAIN WALL FIRE RATING,GYPSUM WALLBOARD SHALL BE LYNNWOOD,WA 98036
<br /> CONTINUOUS TO THE FLOOR SHEATHING TYPICALLY INCLUDING AREAS
<br /> WHERE BATHTUBS,LAVATORIES,AND KITCHEN WALL AND BASE CABINETS
<br /> MAY OCCUR. MD26
<br /> 21 TO PROVIDE ADEQUATE SOUND ATTENUATION COMPLETELY SEAL 2/11/2025
<br /> VERTICAL EDGES,BOUNDARY EDGES,FLOOR JOINTS AND AROUND
<br /> PENETRATIONS IN COMMON WALLS AND/OR CEILINGS COMMON WITH VT
<br /> ADJACENT UNITS OR COMMON STAIRWAYS. LAS
<br /> 22 TRADES REQUIRING HOLES IN STRUCTURAL MEMBERS SHALL CONTACT LAS
<br /> ARCHITECT PRIOR TO CUTTING. D.b, LAS,GE
<br /> 23 THE GENERAL CONTRACTOR IS RESPONSIBLE FOR MEETING THE VT
<br /> REQUIREMENTS STATED THROUGHOUT THE DOCUMENTS,INCLUDING THE
<br /> CODE SHEETS,ABA,AO.2,A0.3. SM1PROJECT DATA&
<br /> GENERALNOTES
<br /> City of Everett Permit Services A0.1
<br /> EVERETT Reviewed for Permit 04/03/2025
<br />
|