To: +1-4252578857 Page 2 of 3 2006-09-15 20:58:03 (GMT) 14257401609 From: Dennis Smiley <br />General <br />xi. The slah floor thermal break Detail T on Sheet 7 does not indicate the foundation required at the <br />shear walls between the garage and the habitable spaces. Rema,-/&-Ok. C.e-+CX tE ll T t1 <br />Z <br />2. The garage floor Should be sloped towards the vehicle doors, per IRC' R309.4. '1'lliie ppos,s supporting <br />the floor -ceiling assembly should also be clad in drywall per IRC R309.2. Acke(eA A v-f e S <br />4-> e e s 5 a•,+ d 7- <br />The sheathing and siding materials should be identified and shown on the slab on grude details. It' <br />the sheathing and/or siding* are wood, and less than 6 inches from the ground, thty should be <br />identified to meet the wood grade and pressure treatment requirements per IRC R319.1 (5). All <br />wood framing members that rest on exterior foundation walls and are less than 9 inches from <br />cu Posed ground also should meet these requirements, per IRC R319.1(2). Gic�Cei to �cti9e% <br />4. )-M] interior and exterior stairs exceeding lour risers should have at least one handrail indicated on the <br />plans, continu(jus between top and bottom risers, per R311.5.6. n �tS�R`.�eA y0 Pages Z <br />5. A building section should be provided to identify the maximum building height and the finished <br />tl(aor elevations relative to the datum indicated on the site plan. <br />The ceiling heights should he identified to be a minimum of 7 feet (exceptions as noted), per 1R.0 <br />R305.1 for all enclosed rooms, including the garage. <br />• any vaulted ceiling heights should be indicated, with the insulation depths and clearance noted on <br />the roof details to meet WSEC 502.1.6.3. <br />• R-30 insulation should be indicated above the garage ceiling. <br />• All cold wails, floors and ceilings should be identified with insulation to meet the prescriptive <br />requirements selected for unlimited glazing, per the WSEC Table 6-1 on Sheet 9. <br />• The number of risers should be indicated for each stair run with intermediate landing elevations <br />noted from the datum indicated on the site plan. "edl 4-o pal& 5 G� awl Z <br />6. 'f he storage room under the stairs should be sheathed with drywall at walls, under the stair surface. <br />and any soffits with 12 inch gypsum board, per IRC R311.2.2. /1 a� Q +0 ^ ug`, Z <br />t 7. All egress components. including doors, should be dimensioned, per IRC R31 1. t(' <br />4Aa --� �-p P�cJ� Z c""& -3 <br />R: A concrete -encased electrode (UFER Ground) should be indicated on the foundation plan per NEC <br />250.50- .Adokc.A 4-0 Paye <br />9. The specific type of insulation (non -compressed or loose fill) below the raffle should be identified at <br />the roof cave, and at the vented rim joists, per .'SEC 502.1.4.5. since this selectior. will impact the <br />dimensions for clearances to the baffle. 11 AAt UJ '�J P��ye s <br />10. Where the ventilation space above the roof/ccilingi`nsulation is less than an average of 12 inches, a <br />vapor retarder should be provided., per WSEC, 502.1.6.3. ctUe-w4je- S ej �eotes <br />r11[avt lZ <br />1 1 _ A vapor retarder should be installed at exterior walls per WSL•'C 502.1.6.6. <br />-ir-v (� qat C S <br />12. The note identifying the solid fuel burning appliances tn%e Living Room should id entity which of <br />the single criteria are being met to satisfy VTAQ Section 402 in regards to 402.2 and 402.3 <br />(Fireplaces). "rhe installation should comply wi Section R1004 and 1005. <br />e d, -1-0 e aecj G Z- <br />13. 'rhe f aundty Room should include the identification of the fuel source 1br the washer and dryer. if <br />they are gas -fired, a combustion air source and venting is required, per WSI C 303A.1.5(d). <br />ads c�e� 4- q9 e — <br />z:'.\411:atuyavor4f\('O6()x-u3(,2os 79th Pt SF 19awc=17_d�k <br />2 sas t ,;d,.iaqu3 -� T L pP6 eob :60 90 a I C�aS <br />